skip to main content


Title: High-throughput and data driven strategies for the design of deep-eutectic solvent electrolytes
Deep eutectic solvents (DESs) are an attractive class of materials with low toxicity, broad commercial availability, low costs and simple synthesis, which allows for tuning of their properties. We develop and demonstrate the use of high-throughput and data-driven strategies to accelerate the investigation of new DES formulations. A cheminformatics approach is used to outline a design space, which results in 3477 hydrogen bond donor (HBD) and 185 quaternary ammonium salt (QAS) molecules identified as good candidate components for DES. The synthesis methodology is then adapted to a high-throughput protocol using liquid handling robots for the rapid synthesis of DES combinations. High-throughput electrochemical characterization and melting point detection systems are used to measure key performance metrics. To demonstrate the new workflow, a total of 600 unique samples are prepared and characterized, corresponding to 50 unique DES combinations at 12 HBD/QAS molar ratios. After synthesis, a total of 230 samples are found liquid at room temperature and further characterized. Several DESs display conductivities above 1 mS cm −1 , with a maximum recorded conductivity of 13.7 mS cm −1 for the combination of acetylcholine chloride (20 mol%) and ethylene glycol. All liquid DES samples show stable potential windows greater than 3 V. We also demonstrate that these DESs are electrochemically limited by viscosity, both in the conductivity and in the limiting processes on their cyclic voltammograms. Comparison with literature reports shows good agreement for properties measured in the high-throughput study, which helps to validate the workflow. This work demonstrates new methods to accelerate the collection of key DES metrics, providing data to formulate robust property prediction models and obtaining insight on interactions between molecular components. Data-driven high-throughput experimentation strategies can accelerate DES development for a variety of applications. Moreover, these approaches can also be extended to tackle other materials challenges with large molecular design spaces.  more » « less
Award ID(s):
1719797 1917340 1633216
NSF-PAR ID:
10326913
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
Molecular Systems Design & Engineering
ISSN:
2058-9689
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. We present a complete open-hardware and software materials acceleration platform (MAP) for sonochemical synthesis of nanocrystals using a versatile tool-changing platform (Jubilee) configured for automated ultrasound application, a liquid-handling robot (Opentrons OT2) and a well-plate spectrometer. An automated high-throughput protocol was developed demonstrating the synthesis of CdSe nanocrystals using sonochemistry and different combinations of sample conditions, including precursor and ligand compositions and concentrations. Cavitation caused by ultrasound fields causes local and transient increases in temperature and pressure sufficient to drive the decomposition of organometallic precursors to drive the chemical reaction leading to nanocrystal formation. A total of 625 unique sample conditions were prepared and analyzed in triplicate with an individual sample volume of as little as 0.5 mL, which drastically reduced chemical waste and experimental times. The rapid onset of cavitation and quick dissipation of energy result in fast nucleation with little nanocrystal growth leading to the formation of small nanocrystals or magic-size clusters (MSCs) depending on composition. Using the effective mass approximation, the calculated QD diameters obtained under all our experimental conditions ranged between 1.3 and 2.1 nm, which was also validated with small angle X-ray scattering (SAXS). Polydispersity, QD shape and optical properties largely varied depending on the concentration of ligands present in solution. Statistical analysis of the spectroscopic data corroborates the qualitative relationships observed from the optical characterization of the samples with the model-agnostic SHAP analysis. The complete workflow relies on relatively low-cost and open-source systems. Automation and the reduced volumes also allow for cost-efficient experimentation, increasing the accessibility of this MAP. The high-throughput capabilities of the automated sonication platform, the extensible nature of the Jubilee system, and the modular nature of the protocol, make the workflow adaptable to a variety of future studies, including other nanocrystal design spaces, emulsification processes, and nanoparticle re-dispersion or exfoliation. 
    more » « less
  2. Abstract

    Deep eutectic solvents (DES) or eutectic mixtures prepared with a chiral component can lead to new chiral solvents with applications that include asymmetric synthesis and chiral light emitting materials. DES have low melting points, because of strong interactions, such as hydrogen bonding, between components of the mixture. Mixtures are prepared with ammonium salts, tetrabutylammonium chloride ([TBA]Cl) and choline chloride ([Ch]Cl), as hydrogen bond acceptor (HBA) and L‐lactic acid, L‐leucic acid, L‐ascorbic acid, R/S‐acetoxypropionic acid, and methyl‐(S)‐lactate as chiral hydrogen bond donors (HBD). Eight combinations of the HBAs and HBDs were prepared, and a racemic mixture of dissymmetric chiral europium complexes was dissolved in the mixtures. The circularly polarized luminescence (CPL) spectra were measured to determine the chiral discrimination by these chiral solvents. The CPL spectra show that the handedness of the chiral HBD is important to the chiral discrimination exhibited. However, the inversion of the sign of the CPL spectra in 1 : 3 [TBA]Cl:L‐lactic acid vs. 1 : 3 [Ch]Cl:L‐lactic acid, and 1 : 1.5 [Ch]Cl:L‐leucic acid vs. 1 : 1 [TBA]Cl:L‐leucic acid shows that the achiral HBA also plays a critical role in the handedness of the chiral discrimination by the chiral solvent.

     
    more » « less
  3. Lipid screening of biological substrates is an important step during biomarker detection and identification. In this work, a fast workflow is described capable of rapid screening for lipid components from biological tissues at ambient pressure based on liquid microjunction extraction in tandem with nano-electrospray ionization (nESI) with ultra-high resolution mass spectrometry, i.e. , liquid extraction surface analysis (LESA) coupled to Fourier-transform ion cyclotron resonance (tandem) mass spectrometry (LESA-FT-ICR-MS/MS). Lipid profiles are presented for thin tissue sections of mouse brain (MB) and liver (ML) samples, analyzed in both positive and negative mode by data-dependent acquisition (DDA) tandem FT-ICR-MS/MS. Candidate assignments were based on fragmentation patterns using mostly SimLipid software and accurate mass using mostly the LipidMaps database (average sub-ppm mass error). A typical, single point surface analysis (<1 mm spatial sampling resolution) lasted less than 15 minutes and resulted in the assignment of (unique and mulitple) lipid identifications of ∼190 (MB) and ∼590 (ML) m / z values. Despite the biological complexity, this led to unique identifications of distinct lipid molecules (sub-ppm mass error) from 38 different lipid classes, corresponding to 10–30% of the lipid m / z identifications. 
    more » « less
  4. Abstract

    In this work, a joint experimental and computational study on the synthesis, self‐assembly, and ionic conduction characteristics of a new conjugated liquid crystal quaterthiophene/poly(ethylene oxide) (PEO4) consisting of terminal tetraethyleneglycol monomethyl ether groups on both ends of a quaterthiophene core is performed. In agreement with molecular dynamic simulations, temperature‐dependent grazing‐incidence wide angle X‐ray scattering and X‐ray diffraction indicate that the molecule spontaneously forms a smectic phase at ambient temperature as characterized both in bulk and thin film configurations. Significantly, this smectic phase is maintained upon blending with bis(trifluoro‐methanesulfonyl)imide as ion source at a concentration ratio up tor= [Li+]/[EO] = 0.05. Nanosegregation between oligothiophene and PEO moieties and π–π stacking of thiophene rings lead to the formation of efficient 2D pathways for ion transport, resulting in thin‐film in‐plane ionic conductivity as high as 5.2 × 10−4S cm−1at 70 °C andr= 0.05 as measured by electrochemical impedance spectroscopy. Upon heating the samples above a transition temperature around 95 °C, an isotropic phase forms associated with a pronounced drop in ionic conductivity. Upon cooling, partial and local reordering of the conducting smectic domains leads to an ionic conductivity decrease compared to the as‐cast state.

     
    more » « less
  5. After attending this presentation, attendees will gain knowledge in the strategy to achieve high-throughput and simultaneous analysis of cannabinoids and appreciate a validated LC-UV method for analysis of twelve cannabinoids in hemp oil. This presentation will first impact the forensic science community by introducing three fast LC separations of twelve cannabinoids that can be used with either UV or mass spectrometric (MS) detection. It will further impact the forensic science community by introducing a validated LC-UV method for high-throughput and simultaneous analysis of twelve cannabinoids in hemp oil, which can be routinely used by cannabis testing labs. In recent years, the use of products of Cannabis sativa L. for medicinal purposes has been in a rapid growth, although their preparation procedure has not been clearly standardized and their quality has not been well regulated. To analyze the therapeutic components, i.e. cannabinoids, in products of Cannabis sativa L., LC-UV has been frequently used, because LC-UV is commonly available and usually appropriate for routine analysis by the cannabis growers and commercial suppliers. In the literature, a few validated LC-UV methods have been described. However, so far, all validated LC-UV methods only focused in the quantification of eleven or less cannabinoids. Therefore, a method able to simultaneously analyze more cannabinoids in a shorter run time is still in high demand, because more and more cannabinoids have been isolated and many of them have shown medicinal properties. In this study, the LC separation of twelve cannabinoids, including cannabichromene (CBC), cannabidiolic acid (CBDA), cannabidiol (CBD), cannabidivarinic acid (CBDVA), cannabidivarin (CBDV), cannabigerolic acid (CBGA), cannabigerol (CBG), cannabinol (CBN), delta-8 tetrahydrocannabinol (Δ8-THC), delta-9 tetrahydrocannabinolic acid A (Δ9-THCA A), delta-9 tetrahydrocannabinol (Δ9-THC), and tetrahydrocannabivarin (THCV), has been systematically optimized using a Phenomenex Luna Omega 3 µm Polar C18 150 mm × 4.6 mm column with regard to the effects of the type of organic solvent, i.e. methanol and acetonitrile, the content of the organic solvent, and the pH of the mobile phase. The optimization has resulted in three LC conditions at 1.0 mL/minute able to separate the twelve cannabinoids: 1) a mobile phase consisting of water and methanol, both containing 0.1% formic acid (pH 2.69), with a gradient elution at 75% methanol for the first 3 minutes and then linearly increase to 100% methanol at 12.5 minutes; 2) a mobile phase consisting of water and 90% (v/v) acetonitrile in water, both containing 0.1% formic acid and 20 mM ammonium formate (pH 3.69), with an isocratic elution at 75% acetonitrile for 14 minutes; and 3) a mobile phase consisting of water and 90% (v/v) acetonitrile in water, both containing 0.03% formic acid and 20 mM ammonium formate (pH 4.20), with an isocratic elution at 75% acetonitrile for 14 minutes. In order to demonstrate the effectiveness of the achieved LC separations, a LC-UV method is further validated for the high-throughput and simultaneous analysis of twelve cannabinoids. The method used the mobile phase at pH 3.69, which resulted in significant improvement in throughput compared to other validated LC-UV methods published so far. The method used flurbiprofen as the internal standard. The linear calibration range of all the cannabinoids were between 0.1 to 25 ppm with R2≥0.9993. The LOQ (S/N=10) of the cannabinoids was between 17.8 and 74.2 ppb. The validation used a hemp oil containing 3.2 wt% CBD and no other cannabinoids, which was reported by the vendor with a certificate of analysis, as the matrix to prepare control samples: the hemp oil was first extracted using liquid-liquid extraction (LLE) with methanol; cannabinoids were then spiked into the extract at both 0.5 ppm and 5 ppm level. Afterwards, the recovery, precision (%RSD) and accuracy (%Error) of the control samples were assessed and the results met the requirements by the ISO/IEC 17025 and ASTM E2549-14 guidelines. 
    more » « less