skip to main content


Title: Experimentally validated x-ray image simulations of 50 μm x-ray PIV tracer particles
Abstract We evaluate Beer–Lambert (BL) ray-tracing and Monte Carlo N-Particle (MCNP) photon tracking simulations for prediction and comparison of x-ray imaging system performance. These simulation tools can aid the methodical design of laboratory-scale x-ray particle image velocimetry (XPIV) experiments and tracer particles by predicting image quality. Particle image signal-to-noise ratio (SNR) is used as the metric of system performance. Simulated and experiment data of hollow, silver-coated, glass sphere tracer particles (AGSF-33) are compared. As predicted by the simulations, the AGSF-33 particles are visible with a SNR greater than unity in 100 ms exposure time images, demonstrating their potential as x-ray PIV or particle tracking velocimetry (XPTV) tracers. The BL approach predicts the image contrast, is computationally inexpensive, and enables the exploration of a vast parameter space for system design. MCNP simulations, on the other hand, predict experiment images slightly more accurately, but are more than an order of magnitude more computationally expensive than BL simulations. For most practical XPIV system design applications, the higher computational expense of MCNP is likely not justified by the modest accuracy improvement compared to BL.  more » « less
Award ID(s):
1922877
NSF-PAR ID:
10330709
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Measurement Science and Technology
Volume:
33
Issue:
5
ISSN:
0957-0233
Page Range / eLocation ID:
055301
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Tracer particles designed specifically for X-ray particle tracking and imaging velocimetry (XPTV and XPIV) are necessary to widen the range of flows that can be studied with these techniques. In this study, we demonstrate in-lab XPTV using new, custom-designedO(50 μm) diameter tungsten-coated hollow carbon spheres and a single energy threshold photon counting detector. To the best knowledge of the authors, these are the firstO(50 μm) tracer particles to be developed specifically for X-ray particle velocimetry. To explore the measurement quality enhancement enabled by the new tracer particles and photon counting detector, a well understood Poiseuille pipe flow is measured. The data show agreement with the analytical solution for the depth-averaged velocity profile. The experiment also shows that the tungsten-coated particles achieve higher contrast and are better localized than previously available silver-coated particles, making faster and more precise measurements attainable. The particles are manufactured with a readily scalable chemical vapor deposition process. We further show that laboratory XPTV is practical with currently available energy-resolving photon counting detectors (PCDs), despite their presently lower spatiotemporal resolution compared to scintillating detectors. This finding suggests that energy-thresholding identification of different classes of tracers is feasible, further motivating the exploration of the X-ray tracer particle design space. The latest generation of PCDs is incorporating multiple energy thresholds, and has higher count rate limits. In the near future one could potentially expand on the work presented and track multiple tracer species and scalar fields simultaneously.

     
    more » « less
  2. Abstract

    We investigate the feasibility of in-laboratory tomographic X-ray particle tracking velocimetry (TXPTV) and consider creeping flows with nearly density matched flow tracers. Specifically, in these proof-of-concept experiments we examined a Poiseuille flow, flow through porous media and a multiphase flow with a Taylor bubble. For a full 360$$^\circ$$computed tomography (CT) scan we show that the specially selected 60 micron tracer particles could be imaged in less than 3 seconds with a signal-to-noise ratio between the tracers and the fluid of 2.5, sufficient to achieve proper volumetric segmentation at each time step. In the pipe flow, continuous Lagrangian particle trajectories were obtained, after which all the standard techniques used for PTV or PIV (taken at visible wave lengths) could also be employed for TXPTV data. And, with TXPTV we can examine flows inaccessible with visible wave lengths due to opaque media or numerous refractive interfaces. In the case of opaque porous media we were able to observe material accumulation and pore clogging, and for flow with Taylor bubble we can trace the particles and hence obtain velocities in the liquid film between the wall and bubble, with thickness of liquid film itself also simultaneously obtained from the volumetric reconstruction after segmentation. While improvements in scan speed are anticipated due to continuing improvements in CT system components, we show that for the flows examined even the presently available CT systems could yield quantitative flow data with the primary limitation being the quality of available flow tracers.

    Graphic abstract 
    more » « less
  3. Abstract

    A typical ground investigation for characterizing geotechnical properties of soil requires sampling soils to test in a laboratory. Laboratory X-ray computed tomography (CT) has been used to non-destructively observe soils and characterize their properties using image processing, numerical analysis, or three-dimensional (3D) printing techniques based on scanned images; however, if it becomes possible to scan the soils in the ground, it may enable the characterization without sampling them. In this study, an in-situ X-ray CT scanning system comprising a drilling machine with an integrated CT scanner was developed. A model test was conducted on gravel soil to verify if the equipment can drill and scan the soil underground. Moreover, image processing was performed on acquired 3D CT images to verify the image quality; the particle morphology (particle size and shape characteristics) was compared with the results obtained for projected particles captured in a two-dimensional (2D) manner by a digital camera. The equipment successfully drilled to a target depth of 800 mm, and the soil was scanned at depths of 700, 750, and 800 mm. Image processing results showed a reasonable agreement between the 3D and 2D particle morphology images, and confirmed the feasibility of the in-situ X-ray CT scanning system.

     
    more » « less
  4. Abstract Particle acceleration mechanisms in supermassive black hole jets, such as shock acceleration, magnetic reconnection, and turbulence, are expected to have observable signatures in the multiwavelength polarization properties of blazars. The recent launch of the Imaging X-Ray Polarimetry Explorer (IXPE) enables us, for the first time, to use polarization in the X-ray band (2–8 keV) to probe the properties of the jet synchrotron emission in high-synchrotron-peaked BL Lac objects (HSPs). We report the discovery of X-ray linear polarization (degree Π x = 15% ± 2% and electric vector position angle ψ x = 35° ± 4°) from the jet of the HSP Mrk 421 in an average X-ray flux state. At the same time, the degree of polarization at optical, infrared, and millimeter wavelengths was found to be lower by at least a factor of 3. During the IXPE pointing, the X-ray flux of the source increased by a factor of 2.2, while the polarization behavior was consistent with no variability. The higher level of Π x compared to longer wavelengths, and the absence of significant polarization variability, suggest a shock is the most likely X-ray emission site in the jet of Mrk 421 during the observation. The multiwavelength polarization properties are consistent with an energy-stratified electron population, where the particles emitting at longer wavelengths are located farther from the acceleration site, where they experience a more disordered magnetic field. 
    more » « less
  5. Nonspherical particles are commonly found when processing biomass or municipal solid waste. In this study, cylindrical particles are used as generic nonspherical particles and are co‐fluidized with small spherical particles. X‐ray particle tracking velocimetry is used to track the three‐dimensional particle position and velocity of a single tagged cylindrical particle over a long time period in the binary fluidized bed. The effects of superficial gas velocity (uf), cylindrical particle mass fraction (α), particle sphericity (Φ), and bed material size on the cylindrical tracer particle location and velocity are investigated. Overall, the cylindrical particles are found in the near‐wall region more often than in the bed center region. Increasing the superficial gas velocityufprovide a slight improvement in the uniformity of the vertical and horizontal distributions. Increasing the cylindrical particle mass fractionαcauses the bed mixing conditions to transition from complete mixing into partial mixing. © 2018 American Institute of Chemical EngineersAIChE J, 65: 520–535, 2019

     
    more » « less