Title: Output of a valveless Liebau pump with biologically relevant vessel properties and compression frequencies
Liebau pump is a tubular, non-peristaltic, pulsatile pump capable of creating unidirectional flow in the absence of valves. It requires asymmetrical positioning of the pincher relative to the attachment sites of its elastic segment to the rest of the circuit. Biological feasibility of such valveless pumps remains a hotly debated topic. To test the feasibility of the Liebau-based pumping in vessels with biologically relevant properties we quantified the output of Liebau pumps with their compliant segments made of a silicone rubber that mimicked the Young modulus of soft tissues. The lengths, the inner diameters, thicknesses of the tested compliant segments ranged from 1 to 5 cm, 3 to 8 mm and 0.3 to 1 mm, respectively. The compliant segment of the setup was compressed at 0.5–2.5 Hz frequencies using a 3.5-mm-wide rectangular piston. A nearest-neighbor tracking algorithm was used to track movements of 0.5-mm carbon particles within the system. The viscosity of the aqueous solution was varied by increased percentage of glycerin. Measurements yielded quantitative relationships between viscosity, frequency of compression and the net flowrate. The use of the Liebau principle of valveless pumping in conjunction with physiologically sized vessel and contraction frequencies yields flowrates comparable to peristaltic pumps of the same dimensions. We conclude that the data confirm physiological feasibility of Liebau-based pumping and warrant further testing of its mechanism using excised biological conduits or tissue engineered components. Such biomimetic pumps can serve as energy-efficient flow generators in microdevices or to study the function of embryonic heart during its normal development or in diseased states.  more » « less
Award ID(s):
1927694
PAR ID:
10332276
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Scientific reports
Volume:
11
Issue:
1
ISSN:
2045-2322
Page Range / eLocation ID:
11505
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Valveless pumping based on Liebau mechanism entails asymmetrical positioning of the compression site relative to the attachment sites of the pump’s elastic segment to the rest of the circuit. Liebau pumping is believed to play a key role during heart development and be involved in several other physiological processes. Until now studies of Liebau pump have been limited to numerical analyses, in silico modeling, experiments using non-biological elements, and a few indirect in vivo measurements. This review aims to stimulate experimental efforts to build Liebau pumps using biologically compatible materials in order to encourage further exploration of the fundamental mechanisms behind valveless pumping and its role in organ physiology. The covered topics include the biological occurrence of Liebau pumps, the main differences between them and the peristaltic flow, and the potential uses and body sites that can benefit from implantable valveless pumps based on Liebau principle. We then provide an overview of currently available tools to build such pumps and touch upon limitations imposed by the use of biological components. We also talk about the many variables that can impact Liebau pump performance, including the concept of resonant frequencies, the shape of the flowrate-frequency relationship, the flow velocity profiles, and the Womersley numbers. Lastly, the choices of materials to build valveless impedance pumps and possible modifications to increase their flow output are briefly discussed. 
    more » « less
  2. A large diversity of fluid pumps is found throughout nature. The study of these pumps has provided insights into fundamental fluid dynamic processes and inspiration for the development of micro-fluid devices. Recent work by Thiria and Zhang [Appl. Phys. Lett. 106, 054106 (2015)] demonstrated how a reciprocal, valveless pump with a geometric asymmetry could drive net fluid flow due to an impedance mismatch when the fluid moves in different directions. Their pump's geometry is reminiscent of the asymmetries seen in the chains of contractile chambers that form the insect heart and mammalian lymphangions. Inspired by these similarities, we further explored the role of such geometric asymmetry in driving bulk flow in a preferred direction. We used an open-source implementation of the immersed boundary method to solve the fluid-structure interaction problem of a viscous fluid moving through a sawtooth channel whose walls move up and down with a reciprocal motion. Using a machine learning approach based on generalized polynomial chaos expansions, we fully described the model's behavior over the target 3-dimensional design space, composed of input Reynolds numbers (Rein), pumping frequencies, and duty cycles. Scaling studies showed that the pump is more effective at higher intermediate Rein. Moreover, greater volumetric flow rates were observed for near extremal duty cycles, with higher duty cycles (longer contraction and shorter expansion phases) resulting in the highest bulk flow rates. 
    more » « less
  3. Pumping is an essential component in many microfluidic applications. Developing simple, small-footprint, and flexible pumping methods is of great importance to achieve truly lab-on-a-chip systems. Here, we report a novel acoustic pump based on the atomization effect induced by a vibrating sharp-tip capillary. As the liquid is atomized by the vibrating capillary, negative pressure is generated to drive the movement of fluid without the need to fabricate special microstructures or use special channel materials. We studied the influence of the frequency, input power, internal diameter (ID) of the capillary tip, and liquid viscosity on the pumping flow rate. By adjusting the ID of the capillary from 30 µm to 80 µm and the power input from 1 Vpp to 5 Vpp, a flow rate range of 3 to 520 µL/min can be achieved. We also demonstrated the simultaneous operation of two pumps to generate parallel flow with a tunable flow rate ratio. Finally, the capability of performing complex pumping sequences was demonstrated by performing a bead-based ELISA in a 3D-printed microdevice. 
    more » « less
  4. null (Ed.)
    Using numerical simulations, we probe the fluid flow in an axisymmetric peristaltic vessel fitted with elastic bi-leaflet valves. In this biomimetic system that mimics the flow generated in lymphatic vessels, we investigate the effects of the valve and vessel properties on pumping performance of the valved peristaltic vessel. The results indicate that valves significantly increase pumping by reducing backflow. The presence of valves, however, increases the viscous resistance, therefore requiring greater work compared to valveless vessels. The benefit of the valves is the most significant when the fluid is pumped against an adverse pressure gradient and for low vessel contraction wave speeds. We identify the optimum vessel and valve parameters leading to the maximum pumping efficiency. We show that the optimum valve elasticity maximizes the pumping flow rate by allowing the valve to block the backflow more effectively while maintaining low resistance during the forward flow. We also examine the pumping in vessels where the vessel contraction amplitude is a function of the adverse pressure gradient, as found in lymphatic vessels. We find that, in this case, the flow is limited by the work generated by the contracting vessel, suggesting that the pumping in lymphatic vessels is constrained by the performance of the lymphatic muscle. Given the regional heterogeneity of valve morphology observed throughout the lymphatic vasculature, these results provide insight into how these variations might facilitate efficient lymphatic transport in the vessel's local physiologic context. 
    more » « less
  5. Recently, there has been an increasing effort in developing new fabrication methods for rapid prototyping of microfluidic chips using laser cutting and 3D printing. However, although these approaches can readily generate rigid parts of the devices, it is not trivial to integrate flexible components (e.g. on-chip valve and/or pump membranes) within the same build. This has led to the recent adoption of thermoplastic polyurethane (TPU) membranes sandwiched between the rigid layers to introduce the necessary flexibility to the chips. Despite its utility, TPU is not without its challenges—it is relatively expensive and surprisingly difficult to source. To overcome these difficulties, our study introduces the use of common food wrapping film as a cost-effective and readily available alternative to TPU, demonstrating its compatibility in fabricating essential microfluidic components such as on-chip valves and peristaltic pumps. Our findings show that this alternative maintains the performance standards required for sophisticated microfluidic applications while significantly alleviating logistical and financial constraints. The results show high cyclability of the membrane, up to 850,000 in continuous testing conditions, at 1 Hz, while also can block the fluid flow at as low as 250 kPa. Regarding the micropumps, it was shown that adequate flow rate of around 4 μL/min can be achieved. 
    more » « less