Abstract Deep vein thrombosis (DVT) and its consequences are lethal, but current models cannot completely dissect its determinants—endothelium, flow, and blood constituents—together called Virchow's triad. Most models for studying DVT forego assessment of venous valves that serve as the primary sites of DVT formation. Therefore, the knowledge of DVT formed at the venous cusps has remained obscure due to lack of experimental models. Here, organ‐on‐chip methodology is leveraged to create a Vein‐Chip platform integrating fully vascularized venous valves and its hemodynamic, as seen in vivo. These Vein‐Chips reveal that vascular endothelium of valve cusps adapts to the locally disturbed microenvironment by expressing a different phenotype from the regions of uniform flow. This spatial adaptation of endothelial function recreated on the in vitro Vein‐Chip platform is shown to protect the vein from thrombosis from disturbed flow in valves, but interestingly, cytokine stimulation reverses the effect and switches the valve endothelium to becoming prothrombotic. The platform eventually modulates the three factors of Virchow's triad and provides a systematic approach to investigate the determinants of fibrin and platelet dynamics of DVT. Therefore, this Vein‐Chip offers a new preclinical approach to study venous pathophysiology and show effects of antithrombotic drug treatment.
more »
« less
In silico analyses of blood flow and oxygen transport in human micro-veins and valves
BACKGROUND: Almost 95% of the venous valves are micron scale found in veins smaller than 300μm diameter. The fluid dynamics of blood flow and transport through these micro venous valves and their contribution to thrombosis is not yet well understood or characterized due to difficulty in making direct measurements in murine models. OBJECTIVE: The unique flow patterns that may arise in physiological and pathological non-actuating micro venous valves are predicted. METHODS: Computational fluid and transport simulations are used to model blood flow and oxygen gradients in a microfluidic vein. RESULTS: The model successfully recreates the typical non-Newtonian vortical flow within the valve cusps seen in preclinical experimental models and in clinic. The analysis further reveals variation in the vortex strengths due to temporal changes in blood flow. The cusp oxygen is typically low from the main lumen, and it is regulated by systemic venous flow. CONCLUSIONS: The analysis leads to a clinically-relevant hypothesis that micro venous valves may not create a hypoxic environment needed for endothelial inflammation, which is one of the main causes of thrombosis. However, incompetent micro venous valves are still locations for complex fluid dynamics of blood leading to low shear regions that may contribute to thrombosis through other pathways.
more »
« less
- Award ID(s):
- 1944322
- PAR ID:
- 10342348
- Date Published:
- Journal Name:
- Clinical Hemorheology and Microcirculation
- Volume:
- 81
- Issue:
- 1
- ISSN:
- 1386-0291
- Page Range / eLocation ID:
- 81 to 96
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Madden, John D.; Anderson, Iain A.; Shea, Herbert R. (Ed.)Wearable dielectric elastomer actuators (DEAs) have been greatly considered for development of biomedical devices. In particular, a DEA cuff device has the capability of minimizing venous system disorders that occur in the lower limbs such as orthostatic intolerance (OI) and deep-vein thrombosis which are a result of substantial blood pooling. Recent works have shown that DEAs could regulate and even enhance venous blood flow return. This wearable technology orders a new light, low-cost, compliant, and simple countermeasure which could be safely and comfortably worn that includes mobility. In addition, it may supplement or even provide an alternative solution to exercise and medication. This work presents the design, model, and characterization of the DEA cuff device design that is capable of generating significant pressure change. A rolled DEA strip was actuated over a simulated muscle-artery apparatus using a periodic voltage input, and fluid pressure change was directly observed. A force sensitive resistor sensor was used to achieve a more precise pressure measurement. Performance analysis was conducted through frequency response analysis. The results provide a framework for implementing dynamic modelling and control to allow various forms of actuation input.more » « less
-
ABSTRACT Oxygen store management underlies dive performance and is dependent on the slow heart rate and peripheral vasoconstriction of the dive response to control tissue blood flow and oxygen uptake. Prior research has revealed two major patterns of muscle myoglobin saturation profiles during dives of emperor penguins. In Type A profiles, myoglobin desaturated rapidly, consistent with minimal muscle blood flow and low tissue oxygen uptake. Type B profiles, with fluctuating and slower declines in myoglobin saturation, were consistent with variable tissue blood flow patterns and tissue oxygen uptake during dives. We examined arterial and venous blood oxygen profiles to evaluate blood oxygen extraction and found two primary patterns of venous hemoglobin desaturation that complemented corresponding myoglobin saturation profiles. Type A venous profiles had a hemoglobin saturation that (a) increased/plateaued for most of a dive's duration, (b) only declined during the latter stages of ascent, and (c) often became arterialized [arterio-venous (a-v) shunting]. In Type B venous profiles, variable but progressive hemoglobin desaturation profiles were interrupted by inflections in the profile that were consistent with fluctuating tissue blood flow and oxygen uptake. End-of-dive saturation of arterial and Type A venous hemoglobin saturation profiles were not significantly different, but did differ from those of Type B venous profiles. These findings provide further support that the dive response of emperor penguins is a spectrum of cardiac and vascular components (including a-v shunting) that are dependent on the nature and demands of a given dive and even of a given segment of a dive.more » « less
-
Project-based learning is an important tool in undergraduate engineering education, providing opportunities for students to deepen their understanding of engineering fundamentals, to enhance their capacity for problem solving and communication, and to develop specific engineering-related skills. Here, we describe the efforts of a team of undergraduate students in creating a silicone venous valve model and experimental flow control setup, and in demonstrating the basic capabilities of the overall experimental system. We describe the process of designing and building the venous valve models and test setup and lessons learned by the students through this experience. In addition to providing invaluable experience for the students involved, this project has provided a visual demonstration of the function of venous valves, and provides a platform for fundamental research on the effect of venous valve shape, size and mechanical properties on the development of disease such as deep vein thrombosis (DVT) and pulmonary embolism (PE), which are a leading cause of death in the United States, especially among hospital patients. Findings from research using this test setup can move us toward a better understanding of patient risk levels for DVT and PE, so that physicians can make informed decisions regarding preventative measures.more » « less
-
Thrombosis and thromboembolism are deadly risk factors in blood-contacting biomedical devices, and in-silico models of thrombosis are attractive tools to understand the mechanics of these processes, though the simulation of thromboembolism remains underdeveloped. The purpose of this study is to modify an existing computational thrombosis model to allow for thromboembolism and to investigate the behavior of the modified model at a range of flow rates. The new and existing models are observed to lead to similar predictions of thrombosis in a canonical backward-facing step geometry across flow rates, and neither model predicts thrombosis in a turbulent flow. Simulations are performed by increasing flow rates in the case of a clot formed at lower flow to induce embolization. While embolization is observed, most of the clot breakdown is by shear rather than by breakup and subsequent transport of clotted material, and further work is required in the formulation and validation of embolization. This model provides a framework to further investigate thromboembolization.more » « less
An official website of the United States government