skip to main content


Title: Temporal modulation of a spectral compressor for efficient quantum storage

Spectral and temporal mode matching are required for the efficient interaction of photons and quantum memories. In our previous work [Opt. Lett.45,5688(2020).10.1364/OL.404891], we proposed a new route to spectrally compress broadband photons to achieve spectral mode matching with narrowband memories, using a linear, time-variant optical cavity based on rapid switching of input coupling. In this work, we extend our approach to attain temporal mode matching as well by exploiting the time variation of output coupling of the cavity. We numerically analyze the mode matching and loss performance of our time-varying cavity and present a possible implementation in integrated photonics.

 
more » « less
Award ID(s):
1809784 1747426
NSF-PAR ID:
10368712
Author(s) / Creator(s):
;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Letters
Volume:
47
Issue:
6
ISSN:
0146-9592; OPLEDP
Page Range / eLocation ID:
Article No. 1387
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. We theoretically study the spectral properties of a pump–probe driven hybrid spinning optomechanical ring resonator optically coupled with a two-level quantum emitter (QE or qubit). Recently, we have shown [Opt. Express27,25515(2019)OPEXFF1094-408710.1364/OE.27.025515] that in the absence of the emitter, the coupled cavity version of this setup is not only capable of non-reciprocal light propagation but can also exhibit slow and fast light propagation. In this work, we investigate in what ways the presence of a single QE coupled with the optical whispering gallery modes of a spinning optomechanical resonator can alter the probe light non-reciprocity. Under the weak-excitation assumption and mean-field approximation, we find that the interplay between the rotational/spinning Sagnac effect and qubit coupling can lead to enhancement of both the optomechanically induced transparency peak value and the width of the transparency window due to the opening of a qubit-assisted backreflection channel. However, compared to the no-qubit case, we notice that such enhancement comes at the cost of degrading the group delay in probe light transmission by a factor of 1/2 for clockwise rotary directions. The target applications of these results can be in the areas of quantum circuitry and in non-reciprocal quantum communication protocols where QEs are a key component.

     
    more » « less
  2. The quarter-wavelength matching technique is widely used because it minimizes the reflection while it maximizes the transmission. The recently introduced antireflection temporal coatings (ATCs) [Optica7,323(2020)10.1364/OPTICA.381175] have been considered as its temporal analog. However, our study shows that by introducing an ATC, not only will the reflection be reduced but also the transmission. This phenomenon is opposite its spatial counterpart, which indicates that ATCs are more than simply a temporal dual of quarter-wavelength matching. This is a direct consequence of the different physical phenomena that are manifested in the temporal and spatial domains.

     
    more » « less
  3. A spatiotemporal optical vortex (STOV) is an intrinsic optical orbital angular momentum (OAM) structure in which the OAM vector is orthogonal to the propagation direction [Optica6,1547(2019)OPTIC82334-253610.1364/OPTICA.6.001547] and the optical phase circulates in space-time. Here, we experimentally and theoretically demonstrate the generation of the second harmonic of a STOV-carrying pulse along with the conservation of STOV-based OAM. Our experiments verify that photons can have intrinsic orbital angular momentum perpendicular to their propagation direction.

     
    more » « less
  4. Structural optical coherence tomography (OCT) images of tissue stand to benefit from greater functionalization and quantitative interpretation. The OCT attenuation coefficientµ, an analogue of the imaged sample’s scattering coefficient, offers potential functional contrast based on the relationship ofµto sub-resolution physical properties of the sample. Attenuation coefficients are computed either by fitting a representativeµover several depth-wise pixels of a sample’s intensity decay, or by using previously-developed depth-resolved attenuation algorithms by Girardet al.[Invest. Ophthalmol. Vis. Sci.52,7738(2011).10.1167/iovs.10-6925] and Vermeeret al.[Biomed. Opt. Express5,322(2014).10.1364/BOE.5.000322]. However, the former method sacrifices axial information in the tomogram, while the latter relies on the stringent assumption that the sample’s backscattering fraction, another optical property, does not vary along depth. This assumption may be violated by layered tissues commonly observed in clinical imaging applications. Our approach preserves the full depth resolution of the attenuation map but removes its dependence on backscattering fraction by performing signal analysis inside individual discrete layers over which the scattering properties (e.g., attenuation and backscattering fraction) vary minimally. Although this approach necessitates the detection of these layers, it removes the constant-backscattering-fraction assumption that has constrained quantitative attenuation coefficient analysis in the past, and additionally yields a layer-resolved backscattering fraction, providing complementary scattering information to the attenuation coefficient. We validate our approach using automated layer detection in layered phantoms, for which the measured optical properties were in good agreement with theoretical values calculated with Mie theory, and show preliminary results in tissue alongside corresponding histological analysis. Together, accurate backscattering fraction and attenuation coefficient measurements enable the estimation of both particle density and size, which is not possible from attenuation measurements alone. We hope that this improvement to depth-resolved attenuation coefficient measurement, augmented by a layer-resolved backscattering fraction, will increase the diagnostic power of quantitative OCT imaging.

     
    more » « less
  5. Surface-enhanced Raman scattering (SERS) spectroscopy is a popular technique for detecting chemicals in small quantities. Rough metallic surfaces with nanofeatures are some of the most widespread and commercially successful substrates for efficient SERS measurements. A rough metallic surface creates a high-density random distribution of so-called “hot spots” with local optical field enhancement causing Raman signal to increase. In this Letter, we revisit the classic SERS experiment [Surf. Sci.158,229(1985)SUSCAS0039-602810.1016/0039-6028(85)90297-3] with rough metallic surfaces covered by a thin layer of copper phthalocyanine molecules. As a modification to the classic configuration, we apply an adaptive wavefront correction of a laser beam profile. As a result, we demonstrate an increase in brightness of local SERS hot spots and redistribution of Raman signal over the substrate area. We hypothesize that the improvement is due to optimal coupling of the shaped laser beam to the random plasmonic nanoantenna configurations. We show that the proposed adaptive-SERS modification is independent of the exact structure of the surface roughness and topography, works with many rough surfaces, and gives brighter Raman hot spots in comparison with conventional SERS measurements. We prove that the adaptive SERS is a powerful instrument for improving SERS sensitivity.

     
    more » « less