Title: Focused surface acoustic wave induced nano-oscillator based reservoir computing
We demonstrate using micromagnetic simulations that a nanomagnet array excited by surface acoustic waves (SAWs) can work as a reservoir. An input nanomagnet is excited with focused SAW and coupled to several nanomagnets, seven of which serve as output nanomagnets. To evaluate memory effect and computing capability, we study the short-term memory (STM) and parity check (PC) capacities, respectively. The SAW (4 GHz carrier frequency) amplitude is modulated to provide a sequence of sine and square waves of 100 MHz frequency. The responses of the selected output nanomagnets are processed by reading the envelope of their magnetization states, which is used to train the output weights using the regression method. For classification, a random sequence of 100 square and sine wave samples is used, of which 80% are used for training, and the rest are used for testing. We achieve 100% training and 100% testing accuracy. The average STM and PC are calculated to be ∼4.69 and ∼5.39 bits, respectively, which is indicative of the proposed acoustically driven nanomagnet oscillator array being well suited for physical reservoir computing applications. The energy dissipation is ∼2.5 times lower than a CMOS-based echo-state network. Furthermore, the reservoir is able to accurately predict Mackey-Glass time series up to several time steps ahead. Finally, the ability to use high frequency SAW makes the nanomagnet reservoir scalable to small dimensions, and the ability to modulate the envelope at a lower frequency (100 MHz) adds flexibility to encode different signals beyond the sine/square waves classification and Mackey-Glass predication tasks demonstrated here.  more » « less
Award ID(s):
1815033
PAR ID:
10376272
Author(s) / Creator(s):
; ; ; ; ; ; ;
Date Published:
Journal Name:
Applied Physics Letters
Volume:
121
Issue:
10
ISSN:
0003-6951
Page Range / eLocation ID:
102402
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Physical Reservoir Computing (PRC) is an unconventional computing paradigm that exploits the nonlinear dynamics of reservoir blocks to perform temporal data classification and prediction tasks. Here, we show with simulations that patterned thin films hosting skyrmion can implement energy-efficient straintronic reservoir computing (RC) in the presence of room-temperature thermal perturbation. This RC block is based on strain-induced nonlinear breathing dynamics of skyrmions, which are coupled to each other through dipole and spin-wave interaction. The nonlinear and coupled magnetization dynamics were exploited to perform temporal data classification and prediction. Two performance metrics, namely Short-Term Memory (STM) and Parity Check (PC) capacity are studied and shown to be promising (4.39 and 4.62 respectively), in addition to showing it can classify sine and square waves with 100% accuracy. These demonstrate the potential of such skyrmion based PRC. Furthermore, our study shows that nonlinear magnetization dynamics and interaction through spin-wave and dipole coupling have a strong influence on STM and PC capacity, thus explaining the role of physical interaction in a dynamical system on its ability to perform RC. 
    more » « less
  2. Conventional electromagnetic (EM) antennas cannot be aggressively miniaturized since their gain and radiation efficiency plummet when their sizes become much smaller than the radiated wavelength. Recently, we demonstrated a new genre of unconventional extreme subwavelength nano-antennas that are several orders of magnitude smaller than the wavelength they radiate, and yet they radiate efficiently, beating the conventional Harrington limits on the gain and radiation efficiency by many orders of magnitude. This is made possible by their unique unconventional mechanism of activation. These nano-antennas are implemented with 2-D periodic arrays of ∼100-nm-sized nanomagnets deposited on piezoelectric substrates. A surface acoustic wave (SAW) launched in the substrate excites resonant spin waves in the nanomagnets at discrete (GHz) frequencies via phonon–magnon coupling, which radiates EM waves very efficiently at those frequencies via magnon–photon coupling. Normally, one would expect such ultrasmall antennas to behave as point sources that radiate isotropically. Surprisingly, they do not because of the intrinsic anisotropy in the nanomagnet array. The radiation patterns in the plane of the nanomagnets and the two transverse planes are anisotropic. By changing the direction of SAW propagation in the plane of the nanomagnets, one can change the radiation patterns in all three planes, which heralds a new method of beam steering or active electronic scanning. 
    more » « less
  3. Abstract We observed strong tripartite magnon-phonon-magnon coupling in a two-dimensional periodic array of magnetostrictive nanomagnets deposited on a piezoelectric substrate, forming a 2D magnetoelastic “crystal”; the coupling occurred between two Kittel-type spin wave (magnon) modes and a (non-Kittel) magnetoelastic spin wave mode caused by a surface acoustic wave (SAW) (phonons). The strongest coupling occurred when the frequencies and wavevectors of the three modes matched, leading to perfect phase matching. We achieved this condition by carefully engineering the frequency of the SAW, the nanomagnet dimensions and the bias magnetic field that determined the frequencies of the two Kittel-type modes. The strong coupling (cooperativity factor exceeding unity) led to the formation of a new quasi-particle, called a binary magnon-polaron, accompanied by nearly complete (~100%) transfer of energy from the magnetoelastic mode to the two Kittel-type modes. This coupling phenomenon exhibited significant anisotropy since the array did not have rotational symmetry in space. The experimental observations were in good agreement with the theoretical simulations. 
    more » « less
  4. Abstract In Part I of this topical review, we discussed dynamical phenomena in nanomagnets, focusing primarily on magnetization reversal with an eye to digital applications. In this part, we address mostly wave-like phenomena in nanomagnets, with emphasis on spin waves in myriad nanomagnetic systems and methods of controlling magnetization dynamics in nanomagnet arrays which may have analog applications. We conclude with a discussion of some interesting spintronic phenomena that undergird the rich physics exhibited by nanomagnet assemblies. 
    more » « less
  5. In this article we use the ensemble Monte-Carlo method to study the frequency comb induced by a periodically excited tunnel junction on a semiconductor. The electron transport is modeled by solving the Boltzmann transport in p-type silicon doped with a concentration of 10 17 cm -3 . For a laser-pulse frequency of 100 MHz, we observe that, if the distance between the STM probe and the second electrode is under 1 μm and we apply a negative bias on the STM tip, the harmonics of the frequency spectrum are not reduced significantly by the electron diffusion and resistance spreading effects in the semiconductor. In this case we obtain a wide frequency comb spectrum, relatively similar to the ones measured experimentally in metals and other materials with high electron conductivity. 
    more » « less