Title: A Self-Tuned Method for Impedance-Matching of Planar-Loop Resonators in Conformable Wearables
Loop structure has been used as a single resonator and in meta-materials. Variations from the loop structures such as split-ring resonators have been utilized as sensing elements in integrated devices for wearable applications or in array configurations for free-space resonance. Previously, impedance formula and equivalent circuit models have been developed for a single loop made of a conductor wire with a negligible wire diameter in the free space. Despite the features of being planar and small, however, the quality factors of single-loop resonators or antennas have not been sufficiently high to use them efficiently for sensing or power transfer. To investigate the limitation, we first experimentally examined the formula and equivalent circuits for a single loop made of planar metal sheets, along with finite element simulations. The loop performance factor was varied to validate the formula and equivalent circuits. Then a tuning element was utilized in the planar loop to improve resonance by providing distributed impedance-matching to the loop. The proposed tuning method was demonstrated with simulations and measurements. A new equivalent circuit model for the tuned loop resonator was established. Quality factors at resonance show significant improvement and the tuning can be done for a specific resonance order without changing the loop radius. It was also shown that the tuning method provided more robust performance for the resonator. The tuning mechanism is suitable for miniature planar device architectures in sensing applications, particularly for implants and wearables that have constraints in dimensions and form factors. The equivalent circuit model can also be applied for meta-materials in arrayed configurations.  more » « less
Award ID(s):
1929953
PAR ID:
10385745
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Electronics
Volume:
11
Issue:
17
ISSN:
2079-9292
Page Range / eLocation ID:
2784
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Mann, Sander; Vellucci, Stefano (Ed.)
    We study the rise of exceptional points of degeneracy (EPD) in various distinct circuit configurations such as gyrator-based coupled resonators, coupled resonators with PT-symmetry, and in a single resonator with a time-varying component. In particular, we analyze their high sensitivity to changes in resistance, capacitance, and inductance and show the high sensitivity of the resonance frequency to perturbations. We also investigate stability and instability conditions for these configurations; for example, the effect of losses in the gyrator-based circuit leads to instability, and it may break the symmetry in the PT-symmetry-based circuit, also resulting in instabilities. Instability in the PT-symmetry circuit is also generated by breaking PT-symmetry when one element (e.g., a capacitor) is perturbed due to sensing. We have turned this instability “inconvenience” to an advantage, and we investigate the effect of nonlinear gain in the PT-symmetry coupled-resonator circuit and how this leads to an oscillator with oscillation frequency very sensitive to perturbation. The circuits studied in this paper have the potential to lead the way for a more efficient generation of high-sensitivity sensors that can detect very small changes in chemical, biological, or physical quantities. 
    more » « less
  2. Abstract This paper delves into the intricate world of whispering gallery mode (WGM) resonators within complex microsphere configurations, exploring their optical properties and behavior. Integrated with optical sensing and processing technology, WGM resonators offer compact size, high sensitivity, rapid response, and tunability. The study investigates the impact of configuration, size, excitation, polarization, and coupling effects on WGM properties. Notable findings include enhanced sensitivity in single microsphere resonators, influence of unequal sphere sizes and excitation locations on WGM modes, and higher quality factors (Q‐factors) in triangular three‐microsphere resonator configurations. Circular polarization was found to elevate Q‐factors, while the nine‐microsphere resonator configuration exhibited increased intensity of dominant WGM peaks with higher laser power, suppressing other peaks. These insights guide the design and optimization of microsphere resonator systems, positioning them for applications in sensing and optical information processing. 
    more » « less
  3. Abstract Implementing microelectromechanical system (MEMS) resonators calls for detailed microscopic understanding of the devices, such as energy dissipation channels, spurious modes, and imperfections from microfabrication. Here, we report the nanoscale imaging of a freestanding super-high-frequency (3 – 30 GHz) lateral overtone bulk acoustic resonator with unprecedented spatial resolution and displacement sensitivity. Using transmission-mode microwave impedance microscopy, we have visualized mode profiles of individual overtones and analyzed higher-order transverse spurious modes and anchor loss. The integrated TMIM signals are in good agreement with the stored mechanical energy in the resonator. Quantitative analysis with finite-element modeling shows that the noise floor is equivalent to an in-plane displacement of 10 fm/√Hz at room temperatures, which can be further improved under cryogenic environments. Our work contributes to the design and characterization of MEMS resonators with better performance for telecommunication, sensing, and quantum information science applications. 
    more » « less
  4. Abstract The nature of nonlinear magnetoelectric (NLME) effect has been investigated at room-temperature in a single-crystal Zn substituted nickel ferrite. Tuning of the frequency of magnetostatic surface wave (MSSW) modes under an applied pulsed DC electric field/current has been utilized to probe the effect. The frequencies of the modes at 8–20 GHz were found to decrease by ~ 400 MHz for an applied DC powerPof ~ 100 mW and the frequency shift was the same for all of the MSSW modes and linearly proportional toP. A model is proposed for the effect and the NLME phenomenon was interpreted in terms of a reduction in the saturation magnetization due to the DC current. The decrease of magnetization with applied electric power, estimated from data on mode frequency versusP, was − 2.50 G/mW. The frequency tuning efficiency of the MSSW modes due to NLME effects in the ferrite resonator was found to be 4.1 MHz/mW which is an order of magnitude higher than the shift reported for M-type strontium and barium hexaferrite resonators investigated earlier. The spinel ferrite resonator discussed here has the potential for miniature, electric field tunable, planar microwave devices for the 8–20 GHz frequency range. 
    more » « less
  5. A compact and planar imaging system was developed using a flexible polymer substrate that can distinguish subcutaneous tissue abnormalities, such as breast tumors, based on electromagnetic-wave interactions in materials where permittivity variations affect wave reflection. The sensing element is a tuned loop resonator operating in the industrial, scientific, and medical (ISM) band at 2.423 GHz, providing a localized high-intensity electric field that penetrates into tissues with sufficient spatial and spectral resolutions. The resonant frequency shifts and magnitudes of the reflection coefficients indicate the boundaries of abnormal tissues under the skin due to their high contrasts to normal tissues. The sensor was tuned to the desired resonant frequency with a reflection coefficient of −68.8 dB for a radius of 5.7 mm, with a tuning pad. Quality factors of 173.1 and 34.4 were achieved in simulations and measurements in phantoms. An image-processing method was introduced to fuse raster-scanned 9 × 9 images of resonant frequencies and reflection coefficients for image-contrast enhancement. The results showed a clear indication of the tumor’s location at a depth of 15 mm and the capability to identify two tumors both at the depth of 10 mm. The sensing element can be expanded to a four-element phased array for deeper field penetration. Field analysis showed the depths of −20 dB attenuation were improved from 19 to 42 mm, giving wider coverage in tissues at resonance. Results showed that a quality factor of 152.5 was achieved and a tumor could be identified at a depth of up to 50 mm. In this work, simulations and measurements were conducted to validate the concept, showing great potential for subcutaneous imaging in medical applications in a noninvasive, efficient, and lower-cost way. 