Title: A Tuned Microwave Resonant System for Subcutaneous Imaging
A compact and planar imaging system was developed using a flexible polymer substrate that can distinguish subcutaneous tissue abnormalities, such as breast tumors, based on electromagnetic-wave interactions in materials where permittivity variations affect wave reflection. The sensing element is a tuned loop resonator operating in the industrial, scientific, and medical (ISM) band at 2.423 GHz, providing a localized high-intensity electric field that penetrates into tissues with sufficient spatial and spectral resolutions. The resonant frequency shifts and magnitudes of the reflection coefficients indicate the boundaries of abnormal tissues under the skin due to their high contrasts to normal tissues. The sensor was tuned to the desired resonant frequency with a reflection coefficient of −68.8 dB for a radius of 5.7 mm, with a tuning pad. Quality factors of 173.1 and 34.4 were achieved in simulations and measurements in phantoms. An image-processing method was introduced to fuse raster-scanned 9 × 9 images of resonant frequencies and reflection coefficients for image-contrast enhancement. The results showed a clear indication of the tumor’s location at a depth of 15 mm and the capability to identify two tumors both at the depth of 10 mm. The sensing element can be expanded to a four-element phased array for deeper field penetration. Field analysis showed the depths of −20 dB attenuation were improved from 19 to 42 mm, giving wider coverage in tissues at resonance. Results showed that a quality factor of 152.5 was achieved and a tumor could be identified at a depth of up to 50 mm. In this work, simulations and measurements were conducted to validate the concept, showing great potential for subcutaneous imaging in medical applications in a noninvasive, efficient, and lower-cost way.  more » « less
Award ID(s):
1929953
PAR ID:
10481679
Author(s) / Creator(s):
; ;
Publisher / Repository:
MDPI
Date Published:
Journal Name:
Sensors
Volume:
23
Issue:
6
ISSN:
1424-8220
Page Range / eLocation ID:
3090
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Soft robotics is an emerging technology that provides robots with the ability to adapt to the environment and safely interact with it. Here, the ability of these robots to identify the surface of interaction is critical for grasping and locomotion tasks. This paper describes the capability of a four-limb soft robot that can identify background materials through the collection of reflection coefficients using an embedded antenna and machine learning techniques. The material of a soft-limb robot was characterized in terms of the relative permittivity and the loss tangent for the design of an antenna to collect reflection coefficients. A slot antenna was designed and embedded into a soft limb in order to extract five features in reflection coefficients including the resonant frequency, −3 dB bandwidth taken from the lowest S11, the value of the lowest S11, −3 dB bandwidth taken from the highest S11, and the number of resonant frequencies. A soft robot with the embedded antenna was tested on nine different background materials in an attempt to identify surrounding terrain information and a better robotic operation. The tested background materials included concrete, fabric, grass, gravel, metal, mulch, soil, water, and wood. The results showed that the robot was capable of distinguishing among the nine different materials with an average accuracy of 93.3% for the nine background materials using a bagged decision-tree-based ensemble method algorithm. 
    more » « less
  2. Photoacoustic imaging has demonstrated recent promise for surgical guidance, enabling visualization of tool tips during surgical and non-surgical interventions. To receive photoacoustic signals, most conventional transducers are rigid, while a flexible array is able to deform and provide complete contact on surfaces with different geometries. In this work, we present photoacoustic images acquired with a flexible array transducer in multiple concave shapes in phantom andex vivobovine liver experiments targeted toward interventional photoacoustic applications. We validate our image reconstruction equations for known sensor geometries with simulated data, and we provide empirical elevation field-of-view, target position, and image quality measurements. The elevation field-of-view was 6.08 mm at a depth of 4 cm and greater than 13 mm at a depth of 5 cm. The target depth agreement with ground truth ranged 98.35-99.69%. The mean lateral and axial target sizes when imaging 600μm-core-diameter optical fibers inserted within the phantoms ranged 0.98-2.14 mm and 1.61-2.24 mm, respectively. The mean ± one standard deviation of lateral and axial target sizes when surrounded by liver tissue were 1.80±0.48 mm and 2.17±0.24 mm, respectively. Contrast, signal-to-noise, and generalized contrast-to-noise ratios ranged 6.92–24.42 dB, 46.50–67.51 dB, and 0.76–1, respectively, within the elevational field-of-view. Results establish the feasibility of implementing photoacoustic-guided surgery with a flexible array transducer. 
    more » « less
  3. We propose a novel photonic circuit element configuration that emulates the through-port response of a bus coupled traveling-wave resonator using two standing-wave resonant cavities. In this “reflectionless resonator unit”, the two constituent cavities, here photonic crystal (PhC) nanobeams, exhibit opposite mode symmetries and may otherwise belong to a single design family. They are coupled evanescently to the bus waveguide without mutual coupling. We show theoretically, and verify using FDTD simulations, that reflection is eliminated when the two cavities are wavelength aligned. This occurs due to symmetry-induced destructive interference at the bus coupling region in the proposed photonic circuit topology. The transmission is equivalent to that of a bus-coupled traveling-wave (e.g. microring) resonator for all coupling conditions. We experimentally demonstrate an implementation fabricated in a new 45 nm silicon-on-insulator complementary metal-oxide semiconductor (SOI CMOS) electronic-photonic process. Both PhC nanobeam cavities have a full-width half-maximum (FWHM) mode length of 4.28μm and measured intrinsic Q’s in excess of 200,000. When the resonances are tuned to degeneracy and coalesce, transmission dips of the over-coupled PhC nanobeam cavities of −16 dB and −17 dB nearly disappear showing a remaining single dip of −4.2 dB, while reflection peaks are simultaneously reduced by 10 dB, demonstrating the quasi-traveling-wave behavior. This photonic circuit topology paves the way for realizing low-energy active devices such as modulators and detectors that can be cascaded to form wavelength-division multiplexed links with smaller power consumption and footprint than traveling wave, ring resonator based implementations. 
    more » « less
  4. Pancreatic ductal adenocarcinoma (PDAC) presents a critical global health challenge, and early detection is crucial for improving the 5-year survival rate. Recent medical imaging and computational algorithm advances offer potential solutions for early diagnosis. Deep learning, particularly in the form of convolutional neural networks (CNNs), has demonstrated success in medical image analysis tasks, including classification and segmentation. However, the limited availability of clinical data for training purposes continues to represent a significant obstacle. Data augmentation, generative adversarial networks (GANs), and cross-validation are potential techniques to address this limitation and improve model performance, but effective solutions are still rare for 3D PDAC, where the contrast is especially poor, owing to the high heterogeneity in both tumor and background tissues. In this study, we developed a new GAN-based model, named 3DGAUnet, for generating realistic 3D CT images of PDAC tumors and pancreatic tissue, which can generate the inter-slice connection data that the existing 2D CT image synthesis models lack. The transition to 3D models allowed the preservation of contextual information from adjacent slices, improving efficiency and accuracy, especially for the poor-contrast challenging case of PDAC. PDAC’s challenging characteristics, such as an iso-attenuating or hypodense appearance and lack of well-defined margins, make tumor shape and texture learning challenging. To overcome these challenges and improve the performance of 3D GAN models, our innovation was to develop a 3D U-Net architecture for the generator, to improve shape and texture learning for PDAC tumors and pancreatic tissue. Thorough examination and validation across many datasets were conducted on the developed 3D GAN model, to ascertain the efficacy and applicability of the model in clinical contexts. Our approach offers a promising path for tackling the urgent requirement for creative and synergistic methods to combat PDAC. The development of this GAN-based model has the potential to alleviate data scarcity issues, elevate the quality of synthesized data, and thereby facilitate the progression of deep learning models, to enhance the accuracy and early detection of PDAC tumors, which could profoundly impact patient outcomes. Furthermore, the model has the potential to be adapted to other types of solid tumors, hence making significant contributions to the field of medical imaging in terms of image processing models. 
    more » « less
  5. This paper presents the novel design of a printed, low-cost, dual-port, and dual-polarized slot antenna for microwave biomedical radars. The butterfly shape of the radiating element, with orthogonally positioned arms, enables simultaneous radiation of both vertically and horizontally polarized waves. The antenna is intended for full-duplex in-band applications using two mutually isolated antenna ports, with the CPW port on the same side of the substrate as the slot antenna and the microstrip port positioned orthogonally on the other side of the substrate. Those two ports can be used as transmit and receive ports in a radar transceiver, with a port isolation of 25 dB. Thanks to the bow-tie shape of the slots and an additional coupling region between the butterfly arms, there is more flexibility in simultaneous optimization of the resonant frequency and input impedance at both ports, avoiding the need for a complicated matching network that introduces the attenuation and increases antenna dimensions. The advantage of this design is demonstrated through the modeling of an eight-element dual-port linear array with an extremely simple feed network for high-gain biosensing applications. To validate the simulation results, prototypes of the proposed antenna were fabricated and tested. The measured operating band of the antennas spans from 2.35 GHz to 2.55 GHz, with reflection coefficients of less than—10 dB, a maximum gain of 8.5 dBi, and a front-to-back gain ratio that is greater than 15 dB, which is comparable with other published single dual-port slot antennas. This is the simplest proposed dual-port, dual-polarization antenna that enables straightforward scaling to other frequency bands. 
    more » « less