Soft robotics is an emerging technology that provides robots with the ability to adapt to the environment and safely interact with it. Here, the ability of these robots to identify the surface of interaction is critical for grasping and locomotion tasks. This paper describes the capability of a four-limb soft robot that can identify background materials through the collection of reflection coefficients using an embedded antenna and machine learning techniques. The material of a soft-limb robot was characterized in terms of the relative permittivity and the loss tangent for the design of an antenna to collect reflection coefficients. A slot antenna was designed and embedded into a soft limb in order to extract five features in reflection coefficients including the resonant frequency, −3 dB bandwidth taken from the lowest S11, the value of the lowest S11, −3 dB bandwidth taken from the highest S11, and the number of resonant frequencies. A soft robot with the embedded antenna was tested on nine different background materials in an attempt to identify surrounding terrain information and a better robotic operation. The tested background materials included concrete, fabric, grass, gravel, metal, mulch, soil, water, and wood. The results showed that the robot was capable of distinguishing among the nine different materials with an average accuracy of 93.3% for the nine background materials using a bagged decision-tree-based ensemble method algorithm.
more »
« less
A Tuned Microwave Resonant System for Subcutaneous Imaging
A compact and planar imaging system was developed using a flexible polymer substrate that can distinguish subcutaneous tissue abnormalities, such as breast tumors, based on electromagnetic-wave interactions in materials where permittivity variations affect wave reflection. The sensing element is a tuned loop resonator operating in the industrial, scientific, and medical (ISM) band at 2.423 GHz, providing a localized high-intensity electric field that penetrates into tissues with sufficient spatial and spectral resolutions. The resonant frequency shifts and magnitudes of the reflection coefficients indicate the boundaries of abnormal tissues under the skin due to their high contrasts to normal tissues. The sensor was tuned to the desired resonant frequency with a reflection coefficient of −68.8 dB for a radius of 5.7 mm, with a tuning pad. Quality factors of 173.1 and 34.4 were achieved in simulations and measurements in phantoms. An image-processing method was introduced to fuse raster-scanned 9 × 9 images of resonant frequencies and reflection coefficients for image-contrast enhancement. The results showed a clear indication of the tumor’s location at a depth of 15 mm and the capability to identify two tumors both at the depth of 10 mm. The sensing element can be expanded to a four-element phased array for deeper field penetration. Field analysis showed the depths of −20 dB attenuation were improved from 19 to 42 mm, giving wider coverage in tissues at resonance. Results showed that a quality factor of 152.5 was achieved and a tumor could be identified at a depth of up to 50 mm. In this work, simulations and measurements were conducted to validate the concept, showing great potential for subcutaneous imaging in medical applications in a noninvasive, efficient, and lower-cost way.
more »
« less
- Award ID(s):
- 1929953
- PAR ID:
- 10481679
- Publisher / Repository:
- MDPI
- Date Published:
- Journal Name:
- Sensors
- Volume:
- 23
- Issue:
- 6
- ISSN:
- 1424-8220
- Page Range / eLocation ID:
- 3090
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Flexible array transducer for photoacoustic-guided interventions: phantom and ex vivo demonstrationsPhotoacoustic imaging has demonstrated recent promise for surgical guidance, enabling visualization of tool tips during surgical and non-surgical interventions. To receive photoacoustic signals, most conventional transducers are rigid, while a flexible array is able to deform and provide complete contact on surfaces with different geometries. In this work, we present photoacoustic images acquired with a flexible array transducer in multiple concave shapes in phantom and ex vivo bovine liver experiments targeted toward interventional photoacoustic applications. We validate our image reconstruction equations for known sensor geometries with simulated data, and we provide empirical elevation field-of-view, target position, and image quality measurements. The elevation field-of-view was 6.08 mm at a depth of 4 cm and greater than 13 mm at a depth of 5 cm. The target depth agreement with ground truth ranged 98.35-99.69%. The mean lateral and axial target sizes when imaging 600 μ m-core-diameter optical fibers inserted within the phantoms ranged 0.98-2.14 mm and 1.61-2.24 mm, respectively. The mean ± one standard deviation of lateral and axial target sizes when surrounded by liver tissue were 1.80±0.48 mm and 2.17±0.24 mm, respectively. Contrast, signal-to-noise, and generalized contrast-to-noise ratios ranged 6.92–24.42 dB, 46.50–67.51 dB, and 0.76–1, respectively, within the elevational field-of-view. Results establish the feasibility of implementing photoacoustic-guided surgery with a flexible array transducer.more » « less
-
The lack of tactile feedback in robot‐assisted minimally invasive surgery (RMIS) limits surgeons’ ability to palpate tissues, a critical technique for locating abnormalities such as tumors. To address this challenge, we introduceTacScope, a novel, vision‐based tactile sensor leveraging the magnification properties of a spherical‐surface elastomer to provide tactile feedback for advanced clinical applications.TacScopefeatures a robust, low‐cost, and easyly fabricate design, enabling seamless integration into surgical robotic setups. It reconstructs high‐resolution 3D geometry from variations in particle‐density distribution across its elastomer surface, requiring only a single image for calibration. The curved elastomer membrane alters particle‐density distribution under contact pressures, enabling detection of both surface‐level and subsurface tissue abnormalities. Unlike conventional vision‐based tactile sensors,TacScopeis compact and tailored for surgical devices. We validated our prototype first on rigid tissue phantoms for tumor detection and shape classification, and extended evaluation to soft‐tissue phantoms under a simulated operative conditions.TacScopeachieved 100% accuracy detecting artificial rigid tumors at depths up to 5 mm and over 90% accuracy classifying four tumor shapes up to 6 mm. It further achieved over 96% accuracy detecting artificial soft tumors 2 mm beneath the surface, confirming its potential for safer, more precise minimally invasive surgery.more » « less
-
This paper presents the novel design of a printed, low-cost, dual-port, and dual-polarized slot antenna for microwave biomedical radars. The butterfly shape of the radiating element, with orthogonally positioned arms, enables simultaneous radiation of both vertically and horizontally polarized waves. The antenna is intended for full-duplex in-band applications using two mutually isolated antenna ports, with the CPW port on the same side of the substrate as the slot antenna and the microstrip port positioned orthogonally on the other side of the substrate. Those two ports can be used as transmit and receive ports in a radar transceiver, with a port isolation of 25 dB. Thanks to the bow-tie shape of the slots and an additional coupling region between the butterfly arms, there is more flexibility in simultaneous optimization of the resonant frequency and input impedance at both ports, avoiding the need for a complicated matching network that introduces the attenuation and increases antenna dimensions. The advantage of this design is demonstrated through the modeling of an eight-element dual-port linear array with an extremely simple feed network for high-gain biosensing applications. To validate the simulation results, prototypes of the proposed antenna were fabricated and tested. The measured operating band of the antennas spans from 2.35 GHz to 2.55 GHz, with reflection coefficients of less than—10 dB, a maximum gain of 8.5 dBi, and a front-to-back gain ratio that is greater than 15 dB, which is comparable with other published single dual-port slot antennas. This is the simplest proposed dual-port, dual-polarization antenna that enables straightforward scaling to other frequency bands.more » « less
-
This paper presents a novel nondestructive testing system, magneto-eddy-current sensor (MECS), to enable surface profiling of dissimilar materials by combining magnetic sensing for ferromagnetic materials and eddy-current sensing for nonferromagnetic materials. The interactions between an electromagnetic field and nonferromagnetic surface and between a magnetic field and ferromagnetic surface were measured by the MECS. The MECS consists of a conic neodymium magnet and a copper coil wound around the magnet. Aluminum and steel surfaces bonded together were prepared to test nondestructive surface profiling of dissimilar materials by the MECS. The interactions between an electromagnetic field and aluminum surface were characterized by monitoring the impedance of the coil, and the interactions between a magnetic field and steel surface were characterized by using a force sensor attached to the neodymium magnet. The magnetic and electromagnetic effects were numerically analyzed by the finite element model. The developed MECS showed the following performance: measurement spot size 5 mm and 10 mm, dynamic measurement bandwidth (eddy-current sensing 1 kHz and magnetic sensing 200 Hz), measuring range 25 mm and 17 mm, polynomial fitting error 0.51% and 0.50%, and resolution 0.655 µm and 0.782 µm for nonferromagnetic and ferromagnetic surface profiling, respectively. This technique was also applied to surface profiling and inspection of the rivet joining sheet materials. The results showed that the MECS is capable of nondestructively monitoring and determining the riveting quality in a fast, large-area, low-cost, convenient manner.more » « less
An official website of the United States government