skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Noble Metal Nanoparticles for Point-of-Care Testing: Recent Advancements and Social Impacts
Point-of-care (POC) tests for the diagnosis of diseases are critical to the improvement of the standard of living, especially for resource-limited areas or countries. In recent years, nanobiosensors based on noble metal nanoparticles (NM NPs) have emerged as a class of effective and versatile POC testing technology. The unique features of NM NPs ensure great performance of associated POC nanobiosensors. In particular, NM NPs offer various signal transduction principles, such as plasmonics, catalysis, photothermal effect, and so on. Significantly, the detectable signal from NM NPs can be tuned and optimized by controlling the physicochemical parameters (e.g., size, shape, and elemental composition) of NPs. In this article, we introduce the inherent merits of NM NPs that make them attractive for POC testing, discuss recent advancement of NM NPs-based POC tests, highlight their social impacts, and provide perspectives on challenges and opportunities in the field. We hope the review and insights provided in this article can inspire new fundamental and applied research in this emerging field.  more » « less
Award ID(s):
1804525 1834874 2004546
PAR ID:
10387111
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
Bioengineering
Volume:
9
Issue:
11
ISSN:
2306-5354
Page Range / eLocation ID:
666
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Nucleic acid detection plays a crucial role in various applications, including disease diagnostics, research development, food safety, and environmental health monitoring. A rapid, point‐of‐care (POC) nucleic acid test can greatly benefit healthcare system by providing timely diagnosis for effective treatment and patient management, as well as supporting diseases surveillance for emerging pandemic diseases. Recent advancements in nucleic acids technology have led to rapid assays for single‐stranded nucleic acids that can be integrated into simple and miniaturized platforms for ease of use. In this review, the study focuses on the developments in isothermal amplification, nucleic acid hybridization circuits, various enzyme‐based signal reporting mechanisms, and detection platforms that show promise for POC testing. The study also evaluates critical technical breakthroughs to identify the advantages and disadvantages of these methods in various applications. 
    more » « less
  2. Abstract Smartphone is emerging as a portable analytical biosensing platform in many point-of-care (POC) applications such as disease diagnostics, environmental monitoring, and food toxin screening. With the recent advancement of imaging technologies on the smartphone, the manual control of acquisition settings (e.g., exposure time, frame rate, focusing distance, etc.) has already been expanded from the photo to the video capturing mode. In modern smartphone models, high frame rate (above 100 fps) can be achieved to bring in a new temporal dimension to the smartphone-supported POC tests by recording high-definition videos. This opens up a new analytical method defined as smartphone videoscopy. In this review, the recent development of smartphone videoscopy is summarized based on different POC applications. Representative examples of smartphone videoscopy systems and how these time-dependent measurements could open up new opportunities for POC diagnostics are discussed in detail. The advances demonstrated so far illustrate the promising future of smartphone videoscopy in biosensing, POC diagnostics, and time-resolved analysis in general. 
    more » « less
  3. Dai, Tianhong; Wu, Mei X.; Popp, Jürgen (Ed.)
    The SARS-CoV-2 pandemic has revealed the need for rapid and inexpensive diagnostic testing to enable population-based screening for active infection. Neither standard diagnostic testing, the detection and measurement of viral RNA (via polymerase chain reaction), or serological testing (via enzyme-linked immunosorbent assay) has the capability to definitively determine active infection. The former due to a lack of ability to distinguish between replicable and inert viral RNA, and the latter due to varying immune responses (ranging from latent to a complete lack of immune response altogether). Despite many companies producing rapid point-of-care (POC) tests, none will address the global scale of testing needed and few help to combat the ever growing issue of testing resource scarcity. Here we discuss our efforts towards the development of a highly manufacturable, microfluidic device that instantly indicates active viral infection status from ~ 20 μL of nasal mucus or phlegm and requires no external power. The device features a biotin functionalized silicon nanomembrane within an acrylic body containing channels and ports for sample introduction and analysis. Virus capture and target confirmation are done using affinity-based capture and size-based occlusion respectively. Modularity of the device is proven with bead and vaccinia virus capture as we work towards testing with both pure SARS-CoV-2 virus and human samples. With success on all fronts, we could achieve an inexpensive POC diagnostic which can determine an individual’s infection status, aiding containment efforts in the current and future pandemics. In addition to direct viral detection, our method can be used as a rapid POC sample preparation tool that limits the application of PCR reagents to those samples which already display viral size and antigen-based positivity through our device. 
    more » « less
  4. We summarize recent advances in the design of hybrid nanostructures through the combination of synthetic polymers and plasmonic nanoparticles (NPs). We categorize the synthetic methods of those polymer-coated metal NPs into two main strategies: direct encapsulation and chemical grafting, based on how NPs interact with polymers. In direct encapsulation, NPs with hydrophobic ligands are physically encapsulated into polymer micelles, primarily through hydrophobic interactions. We discuss strategies for controlling the loading numbers and locations of NPs within polymer micelles. On the other hand, polymer-grafted NPs (PGNPs) have synthetic polymers as ligands chemically grafted on NPs. We highlight that polymer ligands can asymmetrically coat metal NPs through hydrophobicity-driven phase segregation using homopolymers, BCPs and blocky random copolymers. This review provides insights into the methodologies and mechanisms to design new nanostructures of polymers and NPs, aiming to enhance the understanding of this rapidly evolving field. 
    more » « less
  5. The electrophoretic deposition (EPD) of citrate-stabilized Au nanoparticles (cit-Au NPs) occurs on indium tin oxide (ITO)-coated glass electrodes upon electrochemical oxidation of hydroquinone (HQ) due to the release of hydronium ions. Anodic stripping voltammetry (ASV) for Au oxidation allows the determination of the amount of Au NP deposition under a specific EPD potential and time. The binding of Cr 3+ to the cit-Au NPs inhibits the EPD by inducing aggregation and/or reducing the negative charge, which could lower the effective NP concentration of the cit-Au NPs and/or lower the electrophoretic mobility. This lowers the Au oxidation charge in the ASV, which acts as an indirect signal for Cr 3+ . The binding of melamine to cit-Au NPs similarly leads to aggregation and/or lowers the negative charge, also resulting in reduction of the ASV Au oxidation peak. The decrease in Au oxidation charge measured by ASV increases linearly with increasing Cr 3+ and melamine concentration. The limit of detection (LOD) for Cr 3+ is 21.1 ppb and 16.0 ppb for 15.1 and 4.1 nm diameter cit-Au NPs, respectively. Improving the sensing conditions allows for as low as 1 ppb detection of Cr 3+ . The LOD for melamine is 45.7 ppb for 4.1 nm Au NPs. 
    more » « less