skip to main content


Title: A Model of High-Speed Endovascular Sonothrombolysis with Vortex Ultrasound-Induced Shear Stress to Treat Cerebral Venous Sinus Thrombosis
This research aims to demonstrate a novel vortex ultrasound enabled endovascular thrombolysis method designed for treating cerebral venous sinus thrombosis (CVST). This is a topic of substantial importance since current treatment modalities for CVST still fail in as many as 20% to 40% of the cases, and the incidence of CVST has increased since the outbreak of the coronavirus disease 2019 pandemic. Compared with conventional anticoagulant or thrombolytic drugs, sonothrombolysis has the potential to remarkably shorten the required treatment time owing to the direct clot targeting with acoustic waves. However, previously reported strategies for sonothrombolysis have not demonstrated clinically meaningful outcomes (e.g., recanalization within 30 min) in treating large, completely occluded veins or arteries. Here, we demonstrated a new vortex ultrasound technique for endovascular sonothrombolysis utilizing wave-matter interaction-induced shear stress to enhance the lytic rate substantially. Our in vitro experiment showed that the lytic rate was increased by at least 64.3% compared with the nonvortex endovascular ultrasound treatment. A 3.1-g, 7.5-cm-long, completely occluded in vitro 3-dimensional model of acute CVST was fully recanalized within 8 min with a record-high lytic rate of 237.5 mg/min for acute bovine clot in vitro. Furthermore, we confirmed that the vortex ultrasound causes no vessel wall damage over ex vivo canine veins. This vortex ultrasound thrombolysis technique potentially presents a new life-saving tool for severe CVST cases that cannot be efficaciously treated using existing therapies.  more » « less
Award ID(s):
2142555
PAR ID:
10410830
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ;
Date Published:
Journal Name:
Research
Volume:
6
ISSN:
2639-5274
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Endovascular sonothrombolysis has gained significant attention due to its benefits, including direct targeting of the thrombus with sonication and reduced side effects. However, the small aperture of endovascular transducers restricts the improvement of their potential clinical efficiency due to inefficient acoustic radiation. Hence, in an earlier study, we used vortex ultrasound with an endovascular ultrasound transducer to induce shear stress and enhance the clot lysis. In this study, the vortex acoustic transduction mechanism was investigated using numerical simulations and hydrophone tests. Following this characterization, we demonstrated the performance of the vortex ultrasound transducer in thrombolysis of retracted clots in in vitro tests. The test results indicated that the maximum lysis rates were 79.0% and 32.2% with the vortex ultrasound for unretracted and retracted clots, respectively. The vortex ultrasound enhanced the efficiency of the thrombolysis by approximately 49%, both for retracted and unretracted clots, compared with the typical non-vortex ultrasound technique. Therefore, the use of endovascular vortex ultrasound holds promise as a potential clinical option for the thrombolysis of retracted clots.

     
    more » « less
  2. Hagemeyer, Christoph E (Ed.)
    The search persists for a safe and effective agent to lyse arterial thrombi in the event of acute heart attacks or strokes due to thrombotic occlusion. The culpable thrombi are composed either primarily of platelets and von Willebrand Factor (VWF), or polymerized fibrin, depending on the mechanism of formation. Current thrombolytics were designed to target red fibrin-rich clots, but may be not be efficacious on white VWF-platelet-rich arterial thrombi. We have developed an in vitro system to study the efficacy of known and proposed thrombolytic agents on white clots formed from whole blood in a stenosis with arterial conditions. The agents and adjuncts tested were tPA, ADAMTS-13, abciximab, N-acetyl cysteine, and N,N’-Diacetyl-L-cystine (DiNAC). Most of the agents, including tPA, had little thrombolytic effect on the white clots. In contrast, perfusion of DiNAC lysed thrombi as quickly as 1.5 min, which ranged up to 30 min at lower concentrations, and resulted in an average reduction in surface area of 71 ± 20%. The clot burden was significantly reduced compared to both tPA and a saline control ( p <0.0001). We also tested the efficacy of all agents on red fibrinous clots formed in stagnant conditions. DiNAC did not lyse red clots, whereas tPA significantly lysed red clot over 48 h ( p <0.01). These results lead to a novel use for DiNAC as a possible thrombolytic agent against acute arterial occlusions that could mitigate the risk of hyper-fibrinolytic bleeding. 
    more » « less
  3. Purpose: Robotic-assisted carotid artery stenting (CAS) cases have been demonstrated with promising results. However, no quantitative measurements have been made to compare manual with robotic-assisted CAS. This study aims to quantify surgical performance using tool tip kinematic data and metrics of precision during CAS with manual and robotic control in an ex vivo model. Materials and Methods: Transfemoral CAS cases were performed in a high-fidelity endovascular simulator. Participants completed cases with manual and robotic techniques in 2 different carotid anatomies in random order. C-arm angulations, table position, and endovascular devices were standardized. Endovascular tool tip kinematic data were extracted. We calculated the spectral arc length (SPARC), average velocity, and idle time during navigation in the common carotid artery and lesion crossing. Procedural time, fluoroscopy time, movements of the deployed filter wire, precision of stent, and balloon positioning were recorded. Data were analyzed and compared between the 2 modalities. Results: Ten participants performed 40 CAS cases with a procedural success of 100% and 0% residual stenosis. The median procedural time was significantly higher during the robotic-assisted cases (seconds, median [interquartile range, IQR]: 128 [49.5] and 161.5 [62.5], p=0.02). Fluoroscopy time differed significantly between manual and robotic-assisted procedures (seconds, median [IQR]: 81.5 [32] and 98.5 [39.5], p=0.1). Movement of the deployed filter wire did not show significant difference between manual and robotic interventions (mm, median [IQR]: 13 [10.5] and 12.5 [11], p=0.5). The postdilation balloon exceeded the margin of the stent with a median of 2 [1] mm in both groups. Navigation with robotic assistance showed significantly lower SPARC values (–5.78±3.14 and –8.63±3.98, p=0.04) and higher idle time values (8.92±8.71 and 3.47±3.9, p=0.02) than those performed manually. Conclusions: Robotic-assisted and manual CAS cases are comparable in the precision of stent and balloon positioning. Navigation in the carotid artery is associated with smoother motion and higher idle time values. These findings highlight the accuracy and the motion stabilizing capability of the endovascular robotic system. Clinical Impact Robotic assistance in the treatment of peripheral vascular disease is an emerging field and may be a tool for radiation protection and the geographic distribution of endovascular interventions in the future. This preclinical study compares the characteristics of manual and robotic-assisted carotid stenting (CAS). Our results highlight, that robotic-assisted CAS is associated with precise navigation and device positioning, and smoother navigation compared to manual CAS. 
    more » « less
  4. Abstract

    Platelets mediate hemostasis by aggregating and binding to fibrin to promote clotting. Over time, platelets contract the fibrin network to induce clot retraction, which contributes to wound healing outcomes by increasing clot stability and improving blood flow to ischemic tissue. In this study, the development of hollow platelet‐like particles (PLPs) that mimic the native platelet function of clot retraction in a controlled manner is described and it is demonstrated that clot retraction‐inducing PLPs promote healing in vivo. PLPs are created by coupling fibrin‐binding antibodies to CoreShell (CS) or hollowN‐isopropylacrylamide (NIPAm) microgels with varying degrees of shell crosslinking. It is demonstrated that hollow microgels with loosely crosslinked shells display a high degree of deformability and mimic activated platelet morphology, while intact CS microgels and hollow microgels with increased crosslinking in the shell do not. When coupled to a fibrin‐binding antibody to create PLPs, hollow particles with low degrees of shell crosslinking cause fibrin clot collapse in vitro, recapitulating the clot retraction function of platelets, while other particle types do not. Furthermore, hollow PLPs with low degrees of shell crosslinking improve some wound healing outcomes in vivo.

     
    more » « less
  5. Thrombus formation in blood-contacting medical devices is a major concern in the medical device industry, limiting the clinical efficacy of these devices. Further, a locally formed clot within the device has the potential to detach from the surface, posing a risk of embolization. Clot embolization from blood-contacting cardiovascular devices can result in serious complications like acute ischemic stroke and myocardial infarction. Therefore, clot embolization associated with device-induced thrombosis can be life-threatening and requires an enhanced fundamental understanding of embolization characteristics to come up with advanced intervention strategies. Therefore, this work aims to investigate the adhesive characteristics of blood clots on common biocompatible materials used in various cardiovascular devices. This study focuses on characterizing the adhesion strength of blood clots on materials such as polytetrafluoroethylene (PTFE), polyurethane (PU), polyether ether ketone (PEEK), nitinol, and titanium, frequently used in medical devices. In addition, the effect of incubation time on clot adhesion is explored. Results from this work demonstrated strongest clot adhesion to titanium with 3 h of incubation resulting in 1.06 ± 0.20 kPa detachment stresses. The clot adhesion strength on titanium was 51.5% higher than PEEK, 35.9% higher than PTFE, 63.1% higher than PU, and 35.4% higher than nitinol. Further, adhesion strength increases with incubation time for all materials. The percentage increase in detachment stress over incubation time (ranging from 30 min to 3 h) for polymers ranged from at least 108.75% (PEEK), 140.74% (PU), to 151.61% (PTFE). Whereas, for metallic surfaces, the percentage rise ranged from 70.21% (nitinol) to 89.28% (titanium). Confocal fluorescence imaging of clot remnants on the material surfaces revealed a well-bounded platelet-fibrin network at the residual region, representing a comparatively higher adhesive region than the non-residual zone of the surface.

     
    more » « less