skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Evaluation of Robotic-Assisted Carotid Artery Stenting in a Virtual Model Using Motion-Based Performance Metrics
Purpose: Robotic-assisted carotid artery stenting (CAS) cases have been demonstrated with promising results. However, no quantitative measurements have been made to compare manual with robotic-assisted CAS. This study aims to quantify surgical performance using tool tip kinematic data and metrics of precision during CAS with manual and robotic control in an ex vivo model. Materials and Methods: Transfemoral CAS cases were performed in a high-fidelity endovascular simulator. Participants completed cases with manual and robotic techniques in 2 different carotid anatomies in random order. C-arm angulations, table position, and endovascular devices were standardized. Endovascular tool tip kinematic data were extracted. We calculated the spectral arc length (SPARC), average velocity, and idle time during navigation in the common carotid artery and lesion crossing. Procedural time, fluoroscopy time, movements of the deployed filter wire, precision of stent, and balloon positioning were recorded. Data were analyzed and compared between the 2 modalities. Results: Ten participants performed 40 CAS cases with a procedural success of 100% and 0% residual stenosis. The median procedural time was significantly higher during the robotic-assisted cases (seconds, median [interquartile range, IQR]: 128 [49.5] and 161.5 [62.5], p=0.02). Fluoroscopy time differed significantly between manual and robotic-assisted procedures (seconds, median [IQR]: 81.5 [32] and 98.5 [39.5], p=0.1). Movement of the deployed filter wire did not show significant difference between manual and robotic interventions (mm, median [IQR]: 13 [10.5] and 12.5 [11], p=0.5). The postdilation balloon exceeded the margin of the stent with a median of 2 [1] mm in both groups. Navigation with robotic assistance showed significantly lower SPARC values (–5.78±3.14 and –8.63±3.98, p=0.04) and higher idle time values (8.92±8.71 and 3.47±3.9, p=0.02) than those performed manually. Conclusions: Robotic-assisted and manual CAS cases are comparable in the precision of stent and balloon positioning. Navigation in the carotid artery is associated with smoother motion and higher idle time values. These findings highlight the accuracy and the motion stabilizing capability of the endovascular robotic system. Clinical Impact Robotic assistance in the treatment of peripheral vascular disease is an emerging field and may be a tool for radiation protection and the geographic distribution of endovascular interventions in the future. This preclinical study compares the characteristics of manual and robotic-assisted carotid stenting (CAS). Our results highlight, that robotic-assisted CAS is associated with precise navigation and device positioning, and smoother navigation compared to manual CAS.  more » « less
Award ID(s):
2049063
PAR ID:
10414659
Author(s) / Creator(s):
; ; ; ; ; ; ; ;
Date Published:
Journal Name:
Journal of Endovascular Therapy
ISSN:
1526-6028
Page Range / eLocation ID:
152660282211255
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract Endovascular navigation proficiency requires a significant amount of manual dexterity from surgeons. Objective performance measures derived from endovascular tool tip kinematics have been shown to correlate with expertise; however, such metrics have not yet been used during training as a basis for real-time performance feedback. This paper evaluates a set of velocity-based performance measures derived from guidewire motion to determine their suitability for online performance evaluation and feedback. We evaluated the endovascular navigation skill of 75 participants using three metrics (spectral arc length, average velocity, and idle time) as they steered tools to anatomical targets using a virtual reality simulator. First, we examined the effect of navigation task and experience level on performance and found that novice performance was significantly different from intermediate and expert performance. Then we computed correlations between measures calculated online and spectral arc length, our "gold standard" metric, calculated offline (at the end of the trial, using data from the entire trial). Our results suggest that average velocity and idle time calculated online are strongly and consistently correlated with spectral arc length computed offline, which was not the case when comparing spectral arc length computed online and offline. Average velocity and idle time, both time-domain based performance measures, are therefore more suitable measures than spectral arc length, a frequency-domain based metric, to use as the basis of online performance feedback. Future work is needed to determine how to best provide real-time performance feedback to endovascular surgery trainees based on these metrics. 
    more » « less
  2. Atherosclerosis is a prominent cause of coronary artery disease and broader cardiovascular diseases, the leading cause of death worldwide. Angioplasty and stenting is a common treatment, but in-stent restenosis, where the artery re-narrows, is a frequent complication. Restenosis is detected through invasive procedures and is not currently monitored frequently for patients. Here, we report an implantable vascular bioelectronic device using a newly developed miniaturized strain sensor via microneedle printing methods. A capillary-based printing system achieves high-resolution patterning of a soft, capacitive strain sensor. Ink and printing parameters are evaluated to create a fully printed sensor, while sensor design and sensing mechanism are studied to enhance sensitivity and minimize sensor size. The sensor is integrated with a wireless vascular stent, offering a biocompatible, battery-free, wireless monitoring system compatible with conventional catheterization procedures. The vascular sensing system is demonstrated in an artery model for monitoring restenosis progression. Collectively, the artery implantable bioelectronic system shows the potential for wireless, real-time monitoring of various cardiovascular diseases and stent-integrated sensing/treatments. 
    more » « less
  3. Background and objective: Wall shear stress (WSS) has been known to play a critical role in the development of several complications following coronary artery stenting, including in-stent restenosis and thrombosis. Computational fluid dynamics is often used to quantify the post-stenting WSS, which may potentially be used as a predictive metric. However, large-scale studies for WSS-based risk stratification often neglect the footprint of the stent due to reconstruction challenges. The primary objective of this study is to statistically evaluate the impact of the stent footprints (Xience and Resolute stents) on the computed endothelial WSS and quantitatively identify the relationship between these local hemodynamic alterations and the global properties of the vessel, such as curvature, on WSS. The ultimate goal is to evaluate whether and when it is worth including the footprint of the stent in an in-silico study to compute the WSS reliably. Methods: A previously developed semi-automated reconstruction approach for patient-specific coronaries was employed as a part of the SHEAR-STENT trial. A subset of patients was analyzed (N=30), and CFD simulations were performed with and without the stent to evaluate the impact of the stent footprint on WSS. Due to the computationally expensive nature of transient analyses, a sub-cohort of ten patients were used to assess the reliability of WSS obtained from steady computations as a surrogate for the time-averaged results. Global and local vessel curvature data were extracted for all cases and evaluated against stent-induced alterations in the WSS. The differences between the Xience and Resolute stent platforms were also examined to quantify each stent's unique WSS footprint. Results: Results from the surrogate analysis indicate that steady WSS serves as an excellent approximation of the time-averaged computations. The presence of either stent footprint causes a statistically significant decrease in the space-averaged WSS, and a significant increase in the endothelial regions exposed to very low WSS as well (<0.5 Pa). Negative correlations were observed between vessel curvature and WSS differences, indicating that macroscopic vessel characteristics play a more prominent role in determining endothelial WSS at higher curvature values. In our pool of cases, comparison of Xience and Resolute stents revealed that the Resolute platform seems to lead to lower space-averaged WSS and an increase in areas of very low WSS. Conclusion: These results outline (1) the necessity of including the stent footprint for accurate in-silico WSS analysis; (2) the global features of stented arteries serving as the dominant determinant of WSS past a certain curvature threshold; and (3) the Xience stent resulting in a milder presence of hemodynamically unfavorable WSS regions compared to the Resolute stent. Keywords: Computational fluid dynamics; Drug-eluting stents; In-silico clinical trials; Percutaneous coronary intervention; Wall shear stress. 
    more » « less
  4. Vascular stenting is a common intervention for the treatment for atherosclerotic plaques. However, stenting still has a significant rate of restenosis caused by intimal hyperplasia formation. In this study, we evaluate whether stent overexpansion leads to Vasa Vasorum (VV) compression, which may contribute to vascular wall hypoxia and restenosis. An idealized multilayered fibroatheroma model including Vasa Vasorum was expanded by three coronary stent designs up to a 1.3:1 stent/artery luminal diameter ratio (exp1.1, exp1.2, exp1.3) using a finite element analysis approach. Following Poiseuille’s law for elliptical sections, the fold increase in flow resistance was calculated based on VV compression in the Intima (Int), Media (Med) and Adventitia (Adv). The VV beneath the plaque experiences the smallest degree of compression, while the opposite wall regions are highly affected by stent overexpansion. The highest compressions for Adv, Med and Int at exp1.1 are 60.7, 65.9, 72.3%, at exp1.2 are 62.1, 67.3, 73.5% and at expp1.3 are 63.2, 68.7, 74.8%. The consequent fold increase in resistance to flow for Adv, Med and Int at exp1.1 is 3.3, 4.4, 6.6, at exp1.2 is 3.5, 4.7, 7.2 and at exp1.3 is 3.8, 5.1, 7.9. Stent overexpansion induces significant VV compression, especially in the Intima and Media layers, in agreement with previously observed Media necrosis and loss in elasticity after stenting. The observed steep increase in flow resistance suggests the blood flow and associated oxygen delivery would drop up to five times in the Media and almost eight in the Intima, which may lead to intimal hyperplasia and restenosis 
    more » « less
  5. Continuous post-endovascular aneurysm repair (EVAR) surveillance is critical for patients who have undergone a stenting procedure. Despite its life-saving importance, studies have reported that patients gradually discontinue post-EVAR surveillance due to the significant burden associated with CT scans, X-rays, etc. Considering the importance and necessity of post-EVAR surveillance, we introduce a self-resonating flexible tube implanted in a standard clinically approved stent that enables wireless sensing of blood pressure inside an aneurysm through inductive coupling. To enable blood pressure monitoring outside the body, we designed and fabricated a spiral-type antenna, specifically crafted to capture the inherent resonance frequency of the self-resonating stent tube. To showcase the wireless pressure monitoring capability, a 3D-printed elastic model of an abdominal aortic aneurysm (AAA) was prepared. Our quantitative study validated the pressure-sensing capability with adequate sensitivity (up to 687.5 Hz/mmHg) when tissue was located between the stent and the external antenna. The wireless sensing also presents a consistent linear shift in resonance frequency across all tested measuring distances as the applied pressure ranges from 60 to 140 mmHg. The proposed self-resonating stent offers promising insights for improving post-EVAR surveillance. 
    more » « less