Pulsatile pressure at an artery is a collection of harmonics of the heartbeat. This study examines harmonics of pulsatile pressure at different ages and its effect on other pulsatile parameters and waveform-based clinical indices. Based on a vibrating-string model of the arterial tree, wave velocity and characteristic impedance are related to arterial stiffness and radius. Blood velocity, wall shear stress (WSS), and driving force on the left ventricle (LV) are related to pulsatile pressure. Reflection magnitude and return time are related to input impedance. These relations are applied to pulsatile pressure and blood velocity at the ascending aorta (AA) and the carotid artery (CA) at different ages in a database to calculate harmonics of all the pulsatile parameters and reflection magnitude and return time at each harmonic. Harmonics of pulsatile pressure varies with aging and between the two arteries. Reflection magnitude and return time vary between harmonics. While wave reflection manifests the arterial tree (i.e., arterial stiffness and radius) and termination, harmonics of pulsatile pressure is a combination of the LV, the arterial tree, and termination. Harmonics of pulsatile pressure dictates harmonics of WSS and affects endothelial function. Harmonics of pulsatile pressure needs to serve as an independent clinical index indicative of the LV function and endothelial function. Reflection magnitude and return time of the 1st harmonic of pulsatile pressure serve as clinical indices indicative of arterial stiffness and radius.
- Award ID(s):
- 1936005
- PAR ID:
- 10415164
- Date Published:
- Journal Name:
- Journal of Engineering and Science in Medical Diagnostics and Therapy
- Volume:
- 6
- Issue:
- 4
- ISSN:
- 2572-7958
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract -
Abstract Based on a one-dimensional (1D) uniform model of the arterial tree, various machine-learning techniques have been explored to reconstruct aortic pressure waveform (APW) from peripheral pressure waveform (PPW). This study aims to examine the feasibility of such reconstruction. Based on a 1D uniform vibrating-string model, transfer function (TF) of PPW to APW contains four harmonics-dependent parameters: value and phase of reflection coefficient (i.e., load impedance) at periphery and transmission parameter and transmission loss in the aorta-periphery section. Pressure waveforms and blood velocity waveforms at the ascending aorta (AA), the carotid artery (CA), and the radial artery (RA) of virtual health subjects at different ages in a prevalidated database are analyzed to calculate (1) reflection coefficient at the CA and the RA as two peripheries, (2) TF for the AA-CA and AA-RA sections, and (3) transmission parameter and transmission loss in the two sections. Harmonics-dependence of the four parameters varies with aging in both sections, and arterial nonuniformity makes it unpractical to configure any mathematical model for their harmonics-dependence. Instead of fluid-loading, arterial nonuniformity greatly affects transmission loss. Compared with higher harmonics, transmission loss dramatically alters reconstructed APW. A 1D uniform model allows accurate reconstruction of APW from PPW, with a caveat that baseline values of the four parameters at different harmonics under different cardiovascular (CV) conditions need to be established a priori. Alternatively, based on the baseline values, PPW can be directly utilized for inferring CV conditions.
-
Abstract This study examines radial and axial displacement of the arterial wall under the influence of harmonics and wave reflection for the role of axial wall displacement in pulsatile wave propagation. The arterial wall is modeled as an initially-tensioned thin-walled orthotropic tube. In conjunction with three pulsatile parameters in blood flow, a free wave propagation analysis is conducted on the governing equations of the arterial wall and no-slip conditions at the blood-wall interface to obtain the frequency equation and pulsatile parameter expressions under different harmonics. The influence of wave reflection is then added to pulsatile parameter expressions. With the harmonic values of measured pulsatile pressure and blood flow rate at the ascending aorta in the literature, the waveforms of radial wall displacement, axial wall displacement, and wall shear stress are calculated under different orthotropicity and axial initial tension. The developed theory and calculated results indicate that (1) difference in waveform between blood flow rate, wall shear stress, and axial wall displacement is caused by harmonics, rather than wave reflection; (2) Axial wall displacement does not affect blood flow rate, radial wall displacement, and wall shear stress; (3) Besides wall shear stress, radial wall displacement gradient also contributes to axial wall displacement and its contribution is adjusted by axial initial tension; (4) different wave reflections only noticeably affect the maximum and minimum values of wall shear stress; and (5) The amplitude and waveform of axial wall displacement are predominantly dictated by axial elasticity and axial initial tension, respectively.more » « less
-
Abstract Given the wide utility of radial vibration of the arterial wall for clinical values, this paper presents a theoretical study on the relations of radial vibration of the arterial wall to pulsatile parameters in blood flow. Pulse wave propagation in an artery is formulated as a combination of the governing equations of blood flow and the arterial wall and no-slip conditions at the blood-wall interface and is analyzed to obtain the wave velocity and the theoretical expressions for blood flow rate and radial wall displacement in terms of pulsatile pressure. With the harmonics of a pulse signal, theoretical relations of radial vibration of the arterial wall to pulsatile parameters in blood flow are derived under two conditions: without and with wave reflection. These theoretical relations identify the assumptions for the simplified relations employed in the utility of radial vibration of the arterial wall for clinical values. With the arterial wall treated as a unit-mass vibration system, these simplified relations are utilized for extraction of arterial indices from radial vibration of the arterial wall. Other applications of such relations for clinical values are discussed, and the interaction between the arterial wall and blood flow is further revealed from the perspective of energy and one-dimensional wave equations. With harmonics and wave reflection considered, the derived theoretical expressions for radial wall vibration, pulsatile parameters in blood flow, and the relations between them provide theoretical guidance for improving their interpretation of clinical values with clearly defined physiological implications and assumptions.more » « less
-
Estimating central aortic blood pressure is important for cardiovascular health and risk prediction purposes. Cardiovascular system is a multi-channel dynamical system that yields multiple blood pressures at various body sites in response to central aortic blood pressure. This paper concerns the development and analysis of an observer-based approach to de-convolution of unknown input in a class of coprime multi-channel systems applicable to non-invasive estimation of central aortic blood pressure. A multi-channel system yields multiple outputs in response to a common input. Hence, the relationship between any pair of two outputs constitutes a hypothetical input-output system with unknown input embedded as a state. The central idea underlying our approach is to derive the unknown input by designing an observer for the hypothetical input-output system. In this paper, we developed an unknown input observer (UIO) for input de-convolution in coprime multi-channel systems. We provide a universal design algorithm as well as meaningful physical insights and inherent performance limitations associated with the algorithm. The validity and potential of our approach was illustrated using a case study of estimating central aortic blood pressure waveform from two non-invasively acquired peripheral arterial pulse waveforms. The UIO could reduce the root-mean-squared error associated with the central aortic blood pressure by up to 27.5% and 28.8% against conventional inverse filtering and peripheral arterial pulse scaling techniques.more » « less