Title: A 20 A bipolar current source with 140 μ A noise over 100 kHz bandwidth
The precise control of direct current (dc) magnetic fields is crucial in a wide range of experimental platforms, from ultracold quantum gases and nuclear magnetic resonance to precision measurements. In each of these cases, the Zeeman effect causes quantum states to shift in energy as a function of the magnetic field. The development of low-noise current sources is essential because electromagnets are the preferred tool to dynamically control the magnetic field. Here, we describe an ultra-low noise bipolar current source using pairs of complementary n- and p-channel metal–oxide–semiconductor field-effect transistors controlled by zero-drift operational amplifiers. Our source has a 90 kHz inherent bandwidth and provides current from −20 to 20 A with noise (0.1 Hz to 100 kHz) of 140 µA at ±20 A.  more » « less
Award ID(s):
2120757
PAR ID:
10424695
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
AIP Advances
Volume:
13
Issue:
6
ISSN:
2158-3226
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract AB-stacked bilayer graphene has emerged as a fascinating yet simple platform for exploring macroscopic quantum phenomena of correlated electrons. Under large electric displacement fields and near low-density van-Hove singularities, it exhibits a phase with features consistent with Wigner crystallization, including negative dR/dT and nonlinear bias behavior. However, direct evidence for the emergence of an electron crystal at zero magnetic field remains elusive. Here, we explore low-frequency noise consistent with depinning and sliding of a Wigner crystal or solid. At large magnetic fields, we observe enhanced noise at low bias current and a frequency-dependent response characteristic of depinning and sliding, consistent with earlier scanning tunnelling microscopy studies confirming Wigner crystallization in the fractional quantum Hall regime. At zero magnetic field, we detect pronounced AC noise whose peak frequency increases linearly with applied DC current—indicative of collective electron motion. These transport signatures pave the way toward confirming an anomalous Hall crystal. 
    more » « less
  2. Using spin-echo nuclear magnetic resonance in the model transverse field Ising system TmVO4, we show that low frequency quantum fluctuations at the quantum critical point have a very different effect on 51V nuclear spins than classical low-frequency noise or fluctuations that arise at a finite temperature critical point. Spin echoes filter out the low-frequency classical noise but not the quantum fluctuations. This allows us to directly visualize the quantum critical fan and demonstrate the persistence of quantum fluctuations at the critical coupling strength in TmVO4 to high temperatures in an experiment that remains transparent to finite temperature classical phase transitions. These results show that while dynamical decoupling schemes can be quite effective in eliminating classical noise in a qubit, a quantum critical environment may lead to rapid entanglement and decoherence. 
    more » « less
  3. Abstract Quantum sensors based on solid-state defects, in particular nitrogen-vacancy (NV) centers in diamond, enable precise measurement of magnetic fields, temperature, rotation, and electric fields. Cavity quantum electrodynamic (cQED) readout, in which an NV ensemble is hybridized with a microwave mode, can overcome limitations in optical spin detection and has resulted in leading magnetic sensitivities at the pT-level. This approach, however, remains far from the intrinsic spin-projection noise limit due to thermal Johnson-Nyquist noise and spin saturation effects. Here we tackle these challenges by combining recently demonstrated spin refrigeration techniques with comprehensive nonlinear modeling of the cQED sensor operation. We demonstrate that the optically-polarized NV ensemble simultaneously provides magnetic sensitivity and acts as a heat sink for the deleterious thermal microwave noise background, even when actively probed by a microwave field. Optimizing the NV-cQED system, we demonstrate a broadband sensitivity of 576 ± 6 fT/$$\sqrt{{{{\rm{Hz}}}}}$$ Hz around 15 kHz in ambient conditions. We then discuss the implications of this approach for the design of future magnetometers, including near-projection-limited devices approaching 3 fT/$$\sqrt{{{{\rm{Hz}}}}}$$ Hz sensitivity enabled by spin refrigeration. 
    more » « less
  4. The counterpropagating all-normal dispersion (CANDi) fiber laser is an emerging high-energy single-cavity dual-comb laser source. Its relative timing jitter (RTJ), a critical parameter for dual-comb timing precision and spectral resolution, has not been comprehensively investigated. In this paper, we enhance the state-of-the-art CANDi fiber laser pulse energy from 1 nJ to 8 nJ. We then introduce a reference-free RTJ characterization technique that provides shot-to-shot measurement capability at femtosecond precision. The measurement noise floor reaches 1.6 × 10 − 7 f s 2 / H z , and the corresponding integrated measurement precision is only 1.8 fs (1 kHz, 20 MHz). With this characterization tool, we are able to study the physical origin of the CANDi laser’s RTJ in detail. We first verify that the cavity length fluctuation does not contribute to the RTJ. Then we measure the integrated RTJ to be 39 fs (1 kHz, 20 MHz) and identify the pump relative intensity noise (RIN) to be the dominant factor responsible for it. In particular, pump RIN is coupled to the RTJ through the Gordon–Haus effect. Finally, solutions to reduce the free-running CANDi laser’s RTJ are discussed. This work provides a general guideline to improve the performance of compact single-cavity dual-comb systems such as the CANDi laser, benefitting various dual-comb applications. 
    more » « less
  5. We demonstrate indirect electric-field control of ferromagnetic resonance (FMR) in devices that integrate the low-loss, molecule-based, room-temperature ferrimagnet vanadium tetracyanoethylene (V[TCNE]x∼2) mechanically coupled to PMN-PT piezoelectric transducers. Upon straining the V[TCNE]x films, the FMR frequency is tuned by more than 6 times the resonant linewidth with no change in Gilbert damping for samples with α = 6.5 × 10−5. We show this tuning effect is due to a strain-dependent magnetic anisotropy in the films and find the magnetoelastic coefficient |λs| ∼ (1–4.4) ppm, backed by theoretical predictions from density-functional theory calculations and magnetoelastic theory. Noting the rapidly expanding application space for strain-tuned FMR, we define a new metric for magnetostrictive materials, magnetostrictive agility, given by the ratio of the magnetoelastic coefficient to the FMR linewidth. This agility allows for a direct comparison between magnetostrictive materials in terms of their comparative efficacy for magnetoelectric applications requiring ultra-low loss magnetic resonance modulated by strain. With this metric, we show V[TCNE]x is competitive with other magnetostrictive materials, including YIG and Terfenol-D. This combination of ultra-narrow linewidth and magnetostriction, in a system that can be directly integrated into functional devices without requiring heterogeneous integration in a thin film geometry, promises unprecedented functionality for electric-field tuned microwave devices ranging from low-power, compact filters and circulators to emerging applications in quantum information science and technology. 
    more » « less