Hip-worn accelerometers are commonly used, but data processed using the 100 counts per minute cut point do not accurately measure sitting patterns. We developed and validated a model to accurately classify sitting and sitting patterns using hip-worn accelerometer data from a wide age range of older adults. Methods: Deep learning models were trained with 30-Hz triaxial hip-worn accelerometer data as inputs and activPAL sitting/nonsitting events as ground truth. Data from 981 adults aged 35–99 years from cohorts in two continents were used to train the model, which we call CHAP-Adult (Convolutional Neural Network Hip Accelerometer Posture-Adult). Validation was conducted among 419 randomly selected adults not included in model training. Results: Mean errors (activPAL − CHAP-Adult) and 95% limits of agreement were: sedentary time −10.5 (−63.0, 42.0) min/day, breaks in sedentary time 1.9 (−9.2, 12.9) breaks/day, mean bout duration −0.6 (−4.0, 2.7) min, usual bout duration −1.4 (−8.3, 5.4) min, alpha .00 (−.04, .04), and time in ≥30-min bouts −15.1 (−84.3, 54.1) min/day. Respective mean (and absolute) percent errors were: −2.0% (4.0%), −4.7% (12.2%), 4.1% (11.6%), −4.4% (9.6%), 0.0% (1.4%), and 5.4% (9.6%). Pearson’s correlations were: .96, .92, .86, .92, .78, and .96. Error was generally consistent across age, gender, and body mass index groups with the largest deviations observed for those with body mass index ≥30 kg/m2. Conclusions: Overall, these strong validation results indicate CHAP-Adult represents a significant advancement in the ambulatory measurement of sitting and sitting patterns using hip-worn accelerometers. Pending external validation, it could be widely applied to data from around the world to extend understanding of the epidemiology and health consequences of sitting.
more »
« less
CHAP-Adult: A Reliable and Valid Algorithm to Classify Sitting and Measure Sitting Patterns Using Data From Hip-Worn Accelerometers in Adults Aged 35+
Background : Hip-worn accelerometers are commonly used, but data processed using the 100 counts per minute cut point do not accurately measure sitting patterns. We developed and validated a model to accurately classify sitting and sitting patterns using hip-worn accelerometer data from a wide age range of older adults. Methods : Deep learning models were trained with 30-Hz triaxial hip-worn accelerometer data as inputs and activPAL sitting/nonsitting events as ground truth. Data from 981 adults aged 35–99 years from cohorts in two continents were used to train the model, which we call CHAP-Adult (Convolutional Neural Network Hip Accelerometer Posture-Adult). Validation was conducted among 419 randomly selected adults not included in model training. Results : Mean errors (activPAL − CHAP-Adult) and 95% limits of agreement were: sedentary time −10.5 (−63.0, 42.0) min/day, breaks in sedentary time 1.9 (−9.2, 12.9) breaks/day, mean bout duration −0.6 (−4.0, 2.7) min, usual bout duration −1.4 (−8.3, 5.4) min, alpha .00 (−.04, .04), and time in ≥30-min bouts −15.1 (−84.3, 54.1) min/day. Respective mean (and absolute) percent errors were: −2.0% (4.0%), −4.7% (12.2%), 4.1% (11.6%), −4.4% (9.6%), 0.0% (1.4%), and 5.4% (9.6%). Pearson’s correlations were: .96, .92, .86, .92, .78, and .96. Error was generally consistent across age, gender, and body mass index groups with the largest deviations observed for those with body mass index ≥30 kg/m 2 . Conclusions : Overall, these strong validation results indicate CHAP-Adult represents a significant advancement in the ambulatory measurement of sitting and sitting patterns using hip-worn accelerometers. Pending external validation, it could be widely applied to data from around the world to extend understanding of the epidemiology and health consequences of sitting.
more »
« less
- Award ID(s):
- 2100237
- PAR ID:
- 10431829
- Date Published:
- Journal Name:
- Journal for the Measurement of Physical Behaviour
- Volume:
- 5
- Issue:
- 4
- ISSN:
- 2575-6605
- Page Range / eLocation ID:
- 215 to 223
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
null (Ed.)Little is known about how sedentary behavior (SB) metrics derived from hip- and thigh-worn accelerometers agree for older adults. Thigh-worn activPAL (AP) micro monitors were concurrently worn with hip-worn ActiGraph (AG) GT3X+ accelerometers (with SB measured using the 100 counts per minute [cpm] cut point; AG 100cpm ) by 953 older adults (age 77 ± 6.6, 54% women) for 4–7 days. Device agreement for sedentary time and five SB pattern metrics was assessed using mean error and correlations. Logistic regression tested associations with four health outcomes using standardized (i.e., z scores) and unstandardized SB metrics. Mean errors (AP − AG 100cpm ) and 95% limits of agreement were: sedentary time −54.7 [−223.4, 113.9] min/day; time in 30+ min bouts 77.6 [−74.8, 230.1] min/day; mean bout duration 5.9 [0.5, 11.4] min; usual bout duration 15.2 [0.4, 30] min; breaks in sedentary time −35.4 [−63.1, −7.6] breaks/day; and alpha −.5 [−.6, −.4]. Respective Pearson correlations were: .66, .78, .73, .79, .51, and .40. Concordance correlations were: .57, .67, .40, .50, .14, and .02. The statistical significance and direction of associations were identical for AG 100cpm and AP metrics in 46 of 48 tests, though significant differences in the magnitude of odds ratios were observed among 13 of 24 tests for unstandardized and five of 24 for standardized SB metrics. Caution is needed when interpreting SB metrics and associations with health from AG 100cpm due to the tendency for it to overestimate breaks in sedentary time relative to AP. However, high correlations between AP and AG 100cpm measures and similar standardized associations with health outcomes suggest that studies using AG 100cpm are useful, though not ideal, for studying SB in older adults.more » « less
-
Abstract Background Hip-worn accelerometer cut-points have poor validity for assessing children’s sedentary time, which may partly explain the equivocal health associations shown in prior research. Improved processing/classification methods for these monitors would enrich the evidence base and inform the development of more effective public health guidelines. The present study aimed to develop and evaluate a novel computational method (CHAP-child) for classifying sedentary time from hip-worn accelerometer data. Methods Participants were 278, 8–11-year-olds recruited from nine primary schools in Melbourne, Australia with differing socioeconomic status. Participants concurrently wore a thigh-worn activPAL (ground truth) and hip-worn ActiGraph (test measure) during up to 4 seasonal assessment periods, each lasting up to 8 days. activPAL data were used to train and evaluate the CHAP-child deep learning model to classify each 10-s epoch of raw ActiGraph acceleration data as sitting or non-sitting, creating comparable information from the two monitors. CHAP-child was evaluated alongside the current practice 100 counts per minute (cpm) method for hip-worn ActiGraph monitors. Performance was tested for each 10-s epoch and for participant-season level sedentary time and bout variables (e.g., mean bout duration). Results Across participant-seasons, CHAP-child correctly classified each epoch as sitting or non-sitting relative to activPAL, with mean balanced accuracy of 87.6% (SD = 5.3%). Sit-to-stand transitions were correctly classified with mean sensitivity of 76.3% (SD = 8.3). For most participant-season level variables, CHAP-child estimates were within ± 11% (mean absolute percent error [MAPE]) of activPAL, and correlations between CHAP-child and activPAL were generally very large (> 0.80). For the current practice 100 cpm method, most MAPEs were greater than ± 30% and most correlations were small or moderate (≤ 0.60) relative to activPAL. Conclusions There was strong support for the concurrent validity of the CHAP-child classification method, which allows researchers to derive activPAL-equivalent measures of sedentary time, sit-to-stand transitions, and sedentary bout patterns from hip-worn triaxial ActiGraph data. Applying CHAP-child to existing datasets may provide greater insights into the potential impacts and influences of sedentary time in children.more » « less
-
Purpose : Our study evaluated the agreement of mean daily step counts, peak 1-min cadence, and peak 30-min cadence between the hip-worn ActiGraph GT3X+ accelerometer, using the normal filter (AG N ) and the low frequency extension (AG LFE ), and the thigh-worn activPAL3 micro (AP) accelerometer among older adults. Methods : Nine-hundred and fifty-three older adults (≥65 years) were recruited to wear the ActiGraph device concurrently with the AP for 4–7 days beginning in 2016. Using the AP as the reference measure, device agreement for each step-based metric was assessed using mean differences (AG N − AP and AG LFE − AP), mean absolute percentage error (MAPE), and Pearson and concordance correlation coefficients. Results : For AG N − AP, the mean differences and MAPE were: daily steps −1,851 steps/day and 27.2%, peak 1-min cadence −16.2 steps/min and 16.3%, and peak 30-min cadence −17.7 steps/min and 24.0%. Pearson coefficients were .94, .85, and .91 and concordance coefficients were .81, .65, and .73, respectively. For AG LFE − AP, the mean differences and MAPE were: daily steps 4,968 steps/day and 72.7%, peak 1-min cadence −1.4 steps/min and 4.7%, and peak 30-min cadence 1.4 steps/min and 7.0%. Pearson coefficients were .91, .91, and .95 and concordance coefficients were .49, .91, and .94, respectively. Conclusions : Compared with estimates from the AP, the AG N underestimated daily step counts by approximately 1,800 steps/day, while the AG LFE overestimated by approximately 5,000 steps/day. However, peak step cadence estimates generated from the AG LFE and AP had high agreement (MAPE ≤ 7.0%). Additional convergent validation studies of step-based metrics from concurrently worn accelerometers are needed for improved understanding of between-device agreement.more » « less
-
Abstract BackgroundSedentary behavior (SB) is a recognized risk factor for many chronic diseases. ActiGraph and activPAL are two commonly used wearable accelerometers in SB research. The former measures body movement and the latter measures body posture. The goal of the current study is to quantify the pattern and variation of movement (by ActiGraph activity counts) during activPAL-identified sitting events, and examine associations between patterns and health-related outcomes, such as systolic and diastolic blood pressure (SBP and DBP). MethodsThe current study included 314 overweight postmenopausal women, who were instructed to wear an activPAL (at thigh) and ActiGraph (at waist) simultaneously for 24 hours a day for a week under free-living conditions. ActiGraph and activPAL data were processed to obtain minute-level time-series outputs. Multilevel functional principal component analysis (MFPCA) was applied to minute-level ActiGraph activity counts within activPAL-identified sitting bouts to investigate variation in movement while sitting across subjects and days. The multilevel approach accounted for the nesting of days within subjects. ResultsAt least 90% of the overall variation of activity counts was explained by two subject-level principal components (PC) and six day-level PCs, hence dramatically reducing the dimensions from the original minute-level scale. The first subject-level PC captured patterns of fluctuation in movement during sitting, whereas the second subject-level PC delineated variation in movement during different lengths of sitting bouts: shorter (< 30 minutes), medium (30 -39 minutes) or longer (> 39 minute). The first subject-level PC scores showed positive association with DBP (standardized$$\hat{\beta }$$ : 2.041, standard error: 0.607, adjustedp= 0.007), which implied that lower activity counts (during sitting) were associated with higher DBP. ConclusionIn this work we implemented MFPCA to identify variation in movement patterns during sitting bouts, and showed that these patterns were associated with cardiovascular health. Unlike existing methods, MFPCA does not require pre-specified cut-points to define activity intensity, and thus offers a novel powerful statistical tool to elucidate variation in SB patterns and health. Trial registrationClinicalTrials.gov NCT03473145; Registered 22 March 2018;https://clinicaltrials.gov/ct2/show/NCT03473145; International Registered Report Identifier (IRRID): DERR1-10.2196/28684more » « less
An official website of the United States government

