To fulfill the increasing demands of data storage and data processing within modern data centers, a corresponding increase in server performance is necessary. This leads to a subsequent increase in power consumption and heat generation in the servers due to high performance processing units. Currently, air cooling is the most widely used thermal management technique in data centers, but it has started to reach its limitations in cooling of high-power density packaging. Therefore, industries utilizing data centers are looking to singlephase immersion cooling using various dielectric fluids to reduce the operational and cooling costs by enhancing the thermal management of servers. In this study, heat sinks with TPMS lattice structures were designed for application in singlephase immersion cooling of data center servers. These designs are made possible by Electrochemical Additive Manufacturing (ECAM) technology due to their complex topologies. The ECAM process allows for generation of complex heat sink geometries never before possible using traditional manufacturing processes. Geometric complexities including amorphous and porous structures with high surface area to volume ratio enable ECAM heat sinks to have superior heat transfer properties. Our objective is to compare various heat sink geometries by minimizing chip junction temperature in a single-phase immersion cooling setup for natural convection flow regimes. Computational fluid dynamics in ANSYS Fluent is utilized to compare the ECAM heat sink designs. The additively manufactured heat sink designs are evaluated by comparing their thermal performance under natural convection conditions. This study presents a novel approach to heat sink design and bolsters the capability of ECAM-produced heat sinks.
- Award ID(s):
- 2209776
- PAR ID:
- 10435665
- Date Published:
- Journal Name:
- 22nd IEEE ITHERM Conference
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abstract -
Abstract This paper proposes a computational fluid dynamics (CFD) simulation methodology for the multi-design variable optimization of heat sinks for natural convection single-phase immersion cooling of high power-density Data Center server electronics. Immersion cooling provides the capability to cool higher power-densities than air cooling. Due to this, retrofitting Data Center servers initially designed for air-cooling for immersion cooling is of interest. A common area of improvement is in optimizing the air-cooled component heat sinks for the fluid and thermal properties of liquid cooling dielectric fluids. Current heat sink optimization methodologies for immersion cooling demonstrated within the literature rely on a server-level optimization approach. This paper proposes a server-agnostic approach to immersion cooling heat sink optimization by developing a heat sink-level CFD to generate a dataset of optimized heat sinks for a range of variable input parameters: inlet fluid temperature, power dissipation, fin thickness, and number of fins. The objective function of optimization is minimizing heat sink thermal resistance. This research demonstrates an effective modeling and optimization approach for heat sinks. The optimized heat sink designs exhibit improved cooling performance and reduced pressure drop compared to traditional heat sink designs. This study also shows the importance of considering multiple design variables in the heat sink optimization process and extends immersion heat sink optimization beyond server-dependent solutions. The proposed approach can also be extended to other cooling techniques and applications, where optimizing the design variables of heat sinks can improve cooling performance and reduce energy consumption.
-
Abstract Thermal metamaterials exhibit thermal properties that do not exist in nature but can be rationally designed to offer unique capabilities of controlling heat transfer. Recent advances have demonstrated successful manipulation of conductive heat transfer and led to novel heat guiding structures such as thermal cloaks, concentrators, etc. These advances imply new opportunities to guide heat transfer in complex systems and new packaging approaches as related to thermal management of electronics. Such aspects are important, as trends of electronics packaging toward higher power, higher density, and 2.5D/3D integration are making thermal management even more challenging. While conventional cooling solutions based on large thermal-conductivity materials as well as heat pipes and heat exchangers may dissipate the heat from a source to a sink in a uniform manner, thermal metamaterials could help dissipate the heat in a deterministic manner and avoid thermal crosstalk and local hot spots. This paper reviews recent advances of thermal metamaterials that are potentially relevant to electronics packaging. While providing an overview of the state-of-the-art and critical 2.5D/3D-integrated packaging challenges, this paper also discusses the implications of thermal metamaterials for the future of electronic packaging thermal management. Thermal metamaterials could provide a solution to nontrivial thermal management challenges. Future research will need to take on the new challenges in implementing the thermal metamaterial designs in high-performance heterogeneous packages to continue to advance the state-of-the-art in electronics packaging.more » « less
-
Electronic system layouts have increasingly become smaller and more compact. To address the growing demand for performance, dynamic thermal management with thermal energy storage has emerged as an attractive solution. Phase change materials (PCM) can store and release large amounts of heat through melting or solidification. However, they are limited by their thermal conductivity, which is several orders of magnitude lower than traditional heat sinks. To address this design weakness, we have developed a novel composite consisting of vertically aligned carbon nanotube arrays infiltrated with PCM to deliver a high thermal conductivity storage medium that also maintains the high latent heat capacity of the native PCM. This study numerically and experimentally investigates the design of an encapsulated CNT-PCM composite and its impact on the temperature rise and peak temperature of an electronic device. Different form factors have been experimentally tested. The composite's impact on a heating element is measured experimentally, and a numerical model is developed and verified using the experimental results. Additional models are designed to evaluate the effect of composite thickness on thermal response.more » « less
-
Miniaturization of microelectronic components comes at a price of high heat flux density. By adopting liquid cooling, the rising demand of high heat flux devices can be met while the reliability of the microelectronic devices can also be improved to a greater extent. Liquid cooled cold plates are largely replacing air based heat sinks for electronics in data center applications, thanks to its large heat carrying capacity. A bench level study was carried out to characterize the thermohydraulic performance of two microchannel cold plates which uses warm DI water for cooling Multi Chip Server Modules (MCM). A laboratory built mock package housing mock dies and a heat spreader was employed while assessing the thermal performance of two different cold plate designs at varying coolant flow rate and temperature. The case temperature measured at the heat spreader for varying flow rates and input power were essential in identifying the convective resistance. The flow performance was evaluated by measuring the pressure drop across cold plate module at varying flow rates. Cold plate with the enhanced microchannel design yielded better results compared to a traditional parallel microchannel design. The study conducted at higher coolant temperatures yielded lower pressure drop values with no apparent change in the thermal behavior using different cold plates. The tests conducted after reversing the flow direction in microchannels provide an insight at the effect of neighboring dies on each other and reveal the importance of package specific cold plate designs for top performance. The experimental results were validated using a numerical model which are further optimized for improved geometric designs.more » « less