skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Design and development of WFOS, the Wide-Field Optical Spectrograph for the Thirty Meter Telescope
We present the current design of WFOS, a wide-field UV/optical (0.31-1.0 µm) imaging spectrograph planned for first-light on the TMT International Observatory 30 m telescope. WFOS is optimized for high sensitivity across the entire optical waveband for low-to-moderate resolution (R ∼ 1500-5000) long-slit and multi-slit spectroscopy of very faint targets over a contiguous field of view of 8′ .3×3 ′ .0 at the f/15 Nasmyth focus of TMT. A key design goal for WFOS is stability and repeatability in all observing modes, made possible by its gravity-invariant opto-mechanical structure, with a vertical rotation axis and all reconfigurable components moving only in planes defined by tiered optical benches parallel to the Nasmyth platform. WFOS’s optics include a linear ADC correcting a 9′ diameter field, including both the science FoV and 4 patrolling acquisition, guiding, and wavefront sensing camera systems; a novel 2-mirror reflective collimator allowing the science FoV to be centered on the telescope optical axis; a dichroic beamsplitter dividing the collimated beam into 2 wavelength-optimized spectrometer channels (blue: 0.31-0.56 µm; red: 0.54-1.04 µm); selectable transmissive dispersers (VPH and/or VBG) with remotely configurable grating tilt (angle of incidence) and camera articulation that enable optimization of diffraction efficiency and wavelength coverage in each channel; all-refractive, wavelength-optimized f/2 spectrograph cameras, and UV/blue and red-optimized detector systems. The predicted instrumental through put of WFOS for spectroscopy averages > 56% over the full 0.31-1 µm range, from the ADC to the detector. When combined with the 30 m TMT aperture, WFOS will realize a factor of ∼20 gain in sensitivity compared to the current state of the art on 8-10 m-class telescopes.  more » « less
Award ID(s):
2009278
PAR ID:
10436823
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;
Editor(s):
Evans, Christopher J.; Bryant, Julia J.; Motohara, Kentaro
Date Published:
Journal Name:
SPIE 12184, Ground-based and Airborne Instrumentation for Astronomy IX, 1218423 (29 August 2022
Volume:
12184
Page Range / eLocation ID:
74
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Ellis, Simon C.; d'Orgeville, Céline (Ed.)
    Many areas of astronomical research rely on deep blue wide-field imaging. Mauna Kea enjoys the very best UV transparency from the ground and the Keck telescopes with 10 meter f/1.75 primaries are well suited to a prime focus camera with a large angular field. Swinburne University leads a proposal to provide a camera (KWFI, for Keck Wide Field Imager) that is optimized in the UV but works well to 1μm wavelength. Keck has interchangeable top end modules, of which one is now unused and easily capable of housing the required corrector lens and detector enclosure. This paper concentrates on details of the KWFI optical design. 
    more » « less
  2. Evans, Christopher J.; Bryant, Julia J.; Motohara, Kentaro (Ed.)
    NIRSPEC is a high-resolution near-infrared echelle spectrograph on the Keck II telescope that was commissioned in 1999 and upgraded in 2018. This recent upgrade was aimed at improving the sensitivity and longevity of the instrument through the replacement of the spectrometer science detector (SPEC) and slit-viewing camera (SCAM). Commissioning began in 2018 December, producing the first on-sky images used in the characterization of the upgraded system. Through the use of photometry and spectroscopy of standard stars and internal calibration lamps, we assess the performance of the upgraded SPEC and SCAM detectors. First, we evaluate the gain, readnoise, dark current, and the charge persistence of the spec detector. We then characterize the newly upgraded spectrometer and the resulting improvements in sensitivity, including spectroscopic zero points, pixel scale, and resolving power across the spectrometer detector field. Finally, for SCAM, we present zero points, pixel scale, and provide a map of the geometric distortion of the camera. 
    more » « less
  3. Marshall, Heather K; Spyromilio, Jason; Usuda, Tomonori (Ed.)
    We present the optical design for Cryoscope, a 0.26 m aperture telescope that is a f/2 objective operating over the photometric K band (1.99 to 2.55 μm) with diffraction limited imaging. It has a 16 deg2 FoV with a 7.1′′/pix plate scale on a 2048×2048 18 μm/pixel Teledyne H2RG detector array. The objective is a catadioptric design incorporating two thin fused silica meniscus lenses near the entrance aperture, a spherical primary mirror, and a doublet immediately in front of the detector to flatten the image surface. The design solution is capable of delivering diffraction limited images over a 10° field diameter at f/1.25 in the NIR. The use of fused silica for the first two lens elements allows the design to be used for a broad range of applications from the vacuum ultraviolet to thermal IR with only re-optimization of the field flattening doublet. In the VUV (185 to 300 nm) the design is no longer diffraction limited, but can still be made to be pixel limited with detector arrays having pixels as small as 10 μm. The design provides a compact, wide field, and fast objective that can scale to a 1 m-class telescope and offers several benefits over a classical Schmidt telescope. The convex fused silica meniscus lens is strong enough to serve as a vacuum window allowing the entire optical path to be cryogenically cooled to maintain low thermal emission while delivering two orders of magnitude larger field of view than previous ground-based designs for the thermal infrared. 
    more » « less
  4. Abstract We present a sample of 305 QSO candidates having ∣b∣ < 30°, the majority with GALEX magnitudes near-UV < 18.75. To generate this sample, we apply UV–IR color selection criteria to photometric data from the Ultraviolet Galactic Plane Survey as part of GALEX-CAUSE, the Million Quasars Catalog, Gaia DR2, and Pan-STARRS DR1. 165 of these 305 candidate UV-bright active galactic nuclei (AGN; 54%) have published spectroscopic redshifts from 45 different surveys, confirming them as AGN. We further obtained low-dispersion, optical, long-slit spectra with the Apache Point Observatory 3.5 m, MDM 2.4 m, and MDM 1.3 m telescopes for 84 of the candidates, and confirm 86% (N= 72) as AGN, generally withz< 0.6. Of these 72 confirmed AGN, 25 are newly discovered low-latitude QSOs without any previous spectroscopy. These sources fill a gap in the Galactic latitude coverage of the available samples of known UV-bright QSO background probes. Along with a description of the confirmed QSO properties, we provide the fully reduced, flux- and wavelength-calibrated spectra of 72 low-latitude QSOs through the Mikulski Archive for Space Telescopes. Future Hubble Space Telescope/Cosmic Origins Spectrograph spectroscopy of these low-Galactic-latitude QSOs has the potential to transform our view of the Milky Way and Local Group circumgalactic medium. 
    more » « less
  5. Abstract We report the detection of an ionized gas outflow from an X-ray active galactic nucleus hosted in a massive quiescent galaxy in a protocluster at z = 3.09 (J221737.29+001823.4). It is a type-2 QSO with broad ( W 80 > 1000 km s −1 ) and strong ( log ( L [ OIII ] /erg s −1 ) ≈ 43.4) [O iii ] λ λ 4959,5007 emission lines detected by slit spectroscopy in three-position angles using Multi-Object Infra-Red Camera and Spectrograph (MOIRCS) on the Subaru telescope and the Multi-Object Spectrometer For Infra-Red Exploration (MOSFIRE) on the Keck-I telescope. In the all slit directions, [O iii ] emission is extended to ∼15 physical kpc and indicates a powerful outflow spreading over the host galaxy. The inferred ionized gas mass outflow rate is 22 ± 3 M ⊙ yr −1 . Although it is a radio source, according to the line diagnostics using H β , [O ii ], and [O iii ], photoionization by the central QSO is likely the dominant ionization mechanism rather than shocks caused by radio jets. On the other hand, the spectral energy distribution of the host galaxy is well characterized as a quiescent galaxy that has shut down star formation several hundred Myr ago. Our results suggest a scenario that QSOs are powered after the shutdown of the star formation and help complete the quenching of massive quiescent galaxies at high redshift. 
    more » « less