skip to main content


Title: Ambient-temperature liquid jet targets for high-repetition-rate HED discovery science

High-power lasers can generate energetic particle beams and astrophysically relevant pressure and temperature states in the high-energy-density (HED) regime. Recently-commissioned high-repetition-rate (HRR) laser drivers are capable of producing these conditions at rates exceeding 1 Hz. However, experimental output from these systems is often limited by the difficulty of designing targets that match these repetition rates. To overcome this challenge, we have developed tungsten microfluidic nozzles, which produce a continuously replenishing jet that operates at flow speeds of approximately 10 m/s and can sustain shot frequencies up to 1 kHz. The ambient-temperature planar liquid jets produced by these nozzles can have thicknesses ranging from hundreds of nanometers to tens of micrometers. In this work, we illustrate the operational principle of the microfluidic nozzle and describe its implementation in a vacuum environment. We provide evidence of successful laser-driven ion acceleration using this target and discuss the prospect of optimizing the ion acceleration performance through an in situ jet thickness scan. Future applications for the jet throughout HED science include shock compression and studies of strongly heated nonequilibrium plasmas. When fielded in concert with HRR-compatible laser, diagnostic, and active feedback technology, this target will facilitate advanced automated studies in HRR HED science, including machine learning-based optimization and high-dimensional statistical analysis.

 
more » « less
NSF-PAR ID:
10440034
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
American Institute of Physics
Date Published:
Journal Name:
Physics of Plasmas
Volume:
29
Issue:
12
ISSN:
1070-664X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Material in HED regimes are at very high pressures and temperatures but can often still be modeled in the plasma-fluid approximation. Historically HED regimes were created using large laser/ion- beam drivers heating solid targets. Exciting data was obtained from these single shot experiments. In recent years there has been a shift to obtain HED related data from a large number of shots by using high-repetition-rate drivers. For high-repetition-rate experiments a series of droplet targets are often used to have a fresh target/droplet for each shot. However, one must make sure that target debris from the previous shot does not degrade the target for subsequent shots. This is a challenging CFD problem as one needs to model the initial dynamics of the heated droplet and the subsequent interaction with the following droplets. We use the CFD modeling code PISALE to study this complex problem. We discuss results for liquid hydrogen droplets heated by an x-ray free electron laser (XFEL). We first show 2D results for single heated droplet then 3D results for a heated droplet interacting with two unheated droplets. 
    more » « less
  2. Thermo-optical and nonlinear property characterization of refractive optical components is essential for endoscopic instrumentation that utilizes high-power, high-repetition-rate ultrafast lasers. For example, ytterbium-doped fiber lasers are well suited for ultrafast laser microsurgery applications; however, the thermo-optical responses of many common lens substrates are not well understood at 1035 nm wavelength. Using az-scan technique, we first measured the nonlinear refractive indices ofCaF2,MgF2, andBaF2at 1035 nm and found values that match well with those from the literature at 1064 nm. To elucidate effects of thermal lensing, we performedz-scans at multiple laser repetition rates and multiple average powers. The results showed negligible thermal effects up to an average power of 1 W and at 10 W material-specific thermal lensing significantly alteredz-scan measurements. Using a 2D temperature model, we could determine the source of the observed thermal lensing effects. Linear absorption was determined as the main source of heating in these crystals. On the other hand, inclusion of nonlinear absorption as an additional heat source in the simulations showed that thermal lensing in borosilicate glass was strongly influenced by nonlinear absorption. This method can potentially provide a sensitive method to measure small nonlinear absorption coefficients of transparent optical materials. These results can guide design of miniaturized optical systems for ultrafast laser surgery and deep-tissue imaging probes.

     
    more » « less
  3. The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. Here we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. High-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature. 
    more » « less
  4. Laser-induced refractive index change (LIRIC) is being developed as a non-invasive way to alter optical properties of transparent, ophthalmic materials including corneasex vivoandin vivo. This study examined the optical and biological effects of blue-LIRIC (wavelengths 400–405 nm) ofex-vivorabbit corneas. Following LIRIC treatment at low and high repetition rates (8.3 MHz and 80 MHz, respectively), we interferometrically measured optical phase change, obtained transmission electron microscopy (TEM) micrographs, and stained histological sections with collagen hybridizing peptides (CHP) to assess the structural and organizational changes caused by LIRIC at different repetition rates. Finally, we performed power and scan speed scaling experiments at three different repetition rates (1 MHz, 8.3 MHz, and 80 MHz) to study their impact on LIRIC efficacy. Histologic co-localization of CHP and LIRIC-generated green autofluorescence signals suggested that collagen denaturation had occurred in the laser-irradiated region. TEM imaging showed different ultrastructural modifications for low and high repetition rate writing, with discrete homogenization of collagen fibrils at 80 MHz, as opposed to contiguous homogenization at 8.3 MHz. Overall, this study confirmed that LIRIC efficacy can be dramatically increased, while still avoiding tissue ablation, by lowering the repetition rate from 80 MHz to 8.3 MHz. Modeling suggests that this is due to a higher, single-pulse, energy density deposition at given laser powers during 8.3 MHz LIRIC.

     
    more » « less
  5. Throughout the course of an organism’s life, the chemical signatures of environment, food consumption, and weather are recorded into their carbonate structures; these signatures can be directly linked to a time-resolved lifespan. Here we present trace element data from benthic foraminifera and tropical molluscs determined using an ESI NWR193UC excimer laser coupled with an Agilent 8900 triple quadrupole mass spectrometer in the MicroAnalytical Geochemistry and Isotope Characterization (MAGIC) Laboratory at the University of Maine. Benthic foraminifera are protists that live on the sea floor and produce calcite shells, progressively adding chambers. Changes in Mg/Ca in foraminifera are used as a proxy for ocean temperature. Laser ablation ICP-MS data for 18 trace elements were collected in individual growth chambers in foraminifera of the genus Uvigerina from the Bay of Plenty. Line scans were performed within thin (~10 µm) chamber walls using a spot size of 8 µm, beam energy density of 3 J/cm2, repetition rate of 12 Hz, and scan speeds of 2-3 µm/s. Concentrations were determined relative to the NIST610 glass. Ratios of Mg/Ca and other trace elements record the same range of values as those determined via bulk wet chemistry analysis of ~10 foraminifera for a given population, which suggests that LA-ICP-MS may be a viable alternative to wet chemistry. Trace element data were collected across shells of the warm-tropical mollusc species Chione subrugosa from the Ostra Base Camp area, Peru (78°37’22”W, 8°54’46”S). Previous studies of the area have suggested that a large climate transition occurred, transforming a warm water tropical bay into a desert surrounded by a coastal stand with cool waters. This area was occupied by humans at 6250-5450 radiocarbon years BP. This study examines Chione subrugosa, which were found in the living position at the fossilized Ostra Beach and are thought to have been the final living warm-tropical molluscs in the bay. Studies of modern molluscs have revealed that molluscs record massive climatic changes, such as El Niño, in their chemistry. Laser ablation provides a unique opportunity to examine chemical changes directly related to the changing coastal environment. Line scans transverse growth bands along the length of the shell, providing a high resolution record of daily variation in trace element chemistry over the lifespan of the mollusc. Eleven elements were analysed with a beam energy density of 2.4 J/cm2, repetition rate of 15 Hz, spot size of 5 x 25 µm, and a scan speed of 5 µm/s. Preliminary data suggest the preservation of yearly oscillations in trace elements, with high concentrations of La, Ce, U, and Pb during early shell growth. Continued study will examine catastrophic mollusc life events in an effort to link these with environmental climate changes over daily timescales. 
    more » « less