Secondary ion mass spectrometry techniques are used to study trace elements in organic samples where matrix compositions vary spatially. This study was conducted to develop calibrations for lithium content and lithium isotope measurements in kerogen. Known concentrations of Li ions (6Li and 7Li) were implanted into organic polymers, with a range of H/C and O/C ratios similar to kerogen, along with glassy carbon (SPI Glas‐22) and silicate glass (NIST SRM 612). Results show that Li content calibration factors (K*) are similar for carbonaceous samples when analysed using a 5kV secondary ion accelerating voltage. Using a 9 kV secondary ion accelerating voltage, K* factors are negatively correlated with the sample O content, changing ~ 30% between 0 and 15 oxygen atomic %. Thus, to avoid the matrix effect related to O content, using a 5 kV secondary ion accelerating voltage is best for quantification of Li contents based on 7Li+/12C+ ratios. Under these analytical conditions, Li ppm (atomic) = (132 ( 8) × 7Li+/12C+) × 12C atom fraction of the sample measured. Lithium isotope ratio measurements of SPI Glas‐22 and NIST SRM 612 are within uncertainty; however, the organic polymer samples as a group show a 10‰ higher δ7Li than NIST SRM 612.
more »
« less
Secondary ion mass spectrometer analyses for trace elements in glass standards using variably charged silicon ions for normalization
Abstract Trace element analyses of silicate materials by secondary ion mass spectrometry (SIMS) typically normalize the secondary ion count rate for the isotopes of interest to the count rate for one of the silicon isotopes. While the great majority of SIMS analyses use the signal from Si+, some laboratories have used a multiply charged ion (Si2+ or Si3+). We collected data and constructed calibration curves for lithium, beryllium, and boron using these different normalizing species on synthetic basaltic glass and soda-lime silicate glass standards. The calibrations showed little effect of changing matrix when Si+ was used, but larger effects (up to a factor of ~2) when using Si2+ or Si3+ are a warning that care must be taken to avoid inaccurate analyses. The smallest matrix effects were observed at maximum transmission compared to detecting ions with a few tens of eV of initial kinetic energy (“conventional energy filtering”). Normalizing the light element ion intensities to Al3+ showed a smaller matrix effect than multiply-charged Si ions. When normalized to 16O+ (which includes oxygen from the sample and from the primary beam), the two matrices showed distinct calibration curves, suggesting that changing sputter yields (atoms ejected per primary atom impact) may play a role in the probability of producing multiply charged silicon ions.
more »
« less
- Award ID(s):
- 1819550
- PAR ID:
- 10445694
- Date Published:
- Journal Name:
- American Mineralogist
- Volume:
- 108
- Issue:
- 3
- ISSN:
- 0003-004X
- Page Range / eLocation ID:
- 447 to 454
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Secondary ion mass spectrometry techniques are used to study trace elements in organic samples where matrix compositions vary spatially. This study was conducted to develop calibrations for lithium content and lithium isotope measurements in kerogen. Known concentrations of Li ions (6Li and7Li) were implanted into organic polymers, with a range of H/C and O/C ratios similar to kerogen, along with glassy carbon (SPI Glas‐22) and silicate glass (NIST SRM 612). Results show that Li content calibration factors (K*) are similar for carbonaceous samples when analysed using a 5 kV secondary ion accelerating voltage. Using a 9 kV secondary ion accelerating voltage,K* factors are negatively correlated with the sample O content, changing ~ 30% between 0 and 15 oxygen atomic %. Thus, to avoid the matrix effect related to O content, using a 5 kV secondary ion accelerating voltage is best for quantification of Li contents based on7Li+/12C+ratios. Under these analytical conditions, Li ppm (atomic) = (132 (± 8) × 7Li+/12C+) × 12C atom fraction of the sample measured. Lithium isotope ratio measurements of SPI Glas‐22 and NIST SRM 612 are within uncertainty; however, the organic polymer samples as a group show a 10‰ higher δ7Li than NIST SRM 612.more » « less
-
Aldo R. Boccaccini (Ed.)We report doping of thin (~60 nm) amorphous silicon (a-Si) on glass substrate to form n + polycrystalline silicon on glass in selective regions using Monolayer doping (MLD) via Flash Lamp Annealing (FLA). The phosphorus monolayer was formed on the exposed regions of SiO2 patterned a-Si, through functionalization with chemically bound Diethyl vinylphosphonate (DVP) dopant molecules. The samples were capped with SiO2 and annealed using a single xenon flash pulse (5.0 J/cm2, 250 μs) to simultaneously crystallize a-Si, incorporate and activate phosphorus dopants. SIMS results show an average concentration of 8x1019 cm−3 in the 60 nm of thin silicon on glass. Electrical results show a resistivity of ~6.60x10−2 Ω.cm in doped regions. N-channel field effect transistor devices are successfully demonstrated using this MLD-FLA technique.more » « less
-
Abstract Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a versatile surface-sensitive technique for characterizing both hard and soft matter. Its chemical and molecular specificity, high spatial resolution, and superior sensitivity make it an ideal method for depth profiling polymeric systems, including those comprised of both inorganic and organic constituents (i.e., polymer nanocomposites, PNCs). To best utilize ToF-SIMS for characterizing PNCs, experimental conditions must be optimized to minimize challenges such as the matrix effect and charge accumulation. Toward that end, we have successfully used ToF-SIMS with a Xe+ focused ion beam to depth profile silica nanoparticles grafted with poly(methyl methacrylate) (PMMA-NP) in a poly(styrene-ran-acrylonitrile) matrix film by selecting conditions that address charge compensation and the primary incident beam angles. By tracking the sputtered Si+ species and fitting the resultant concentration profile, the diffusion coefficient of PMMA-NP was determined to be D = 2.4 × 10−14 cm2/s. This value of D lies between that measured using Rutherford backscattering spectrometry (6.4 × 10−14 cm2/s) and the value predicted by the Stokes–Einstein model (2.5 × 10−15 cm2/s). With carefully tuned experimental parameters, ToF-SIMS holds great potential for quantitatively characterizing the nanoparticles at the surfaces and interfaces within PNC materials as well as soft matter in general.more » « less
-
Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07<0.83) and Ge1-zSnz (0.066<0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011<0.113, 0.863<0.935 and 0.023<0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. The proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.more » « less