skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: EFFECTS OF OSMOLARITY ON ULTRASOUND-INDUCED MEMBRANE DEPOLARIZATION IN ISOLATED CRAYFISH MOTOR AXON
Abstract—We have previously identified a novel non-selective membrane conductance (gUS) opened by focused ultrasound (FUS) in crayfish motor axons. In the work described here, we studied gUS properties further by comparing FUS-evoked depolarization (FUSD) in control and hypotonic saline with 75% of control osmolarity. The FUS was a train of 20 FUS bursts (2.1 MHz and 50 ms per burst) delivered at 1 kHz. The amplitude, onset latency, frequency of occurrence and duration of FUSD were compared in a 15-min time window before and after switching to hypotonic saline. Significant increases were observed for amplitude (p < 0.001) and frequency of occurrence (p < 0.01) while the onset latency exhibited a significant decrease (p < 0.001). FUSD duration did not significantly differ. These results support predictions based on our hypothesis that gUS is mediated by opening of nanopores in the lipid bilayer and that stretching of axonal membrane caused by swelling at low osmolarity should increase the probability of nanopore formation under FUS. The FUSD parameters, in addition, exhibited time-dependent trends when the window of observation was expanded to 45 min in each saline. The statistical significance of amplitude and duration differed between 15- and 45-min time windows, indicating the presence of adaptive responses of axonal membrane to osmotic manipulation. (E-mail: jenweilin@bu.edu) © 2022 Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.  more » « less
Award ID(s):
1707865
PAR ID:
10475332
Author(s) / Creator(s):
Publisher / Repository:
Elsevier
Date Published:
Journal Name:
Ultrasound in medicine biology
ISSN:
0301-5629
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract The long‐term statistical characteristics of high‐frequency quasi‐monochromatic gravity waves are presented using multi‐year airglow images observed at Andes Lidar Observatory (ALO, 30.3°S, 70.7°W) in northern Chile. The distribution of primary gravity wave parameters including horizontal wavelength, vertical wavelength, intrinsic wave speed, and intrinsic wave period are obtained and are in the ranges of 20–30 km, 15–25 km, 50–100 m s−1, and 5–10 min, respectively. The duration of persistent gravity wave events captured by the imager approximately follows an exponential distribution with an average duration of 7–9 min. The waves tend to propagate against the local background winds and show evidence of seasonal variations. In austral winter (May–August), the observed wave occurrence frequency is higher, and preferential wave propagation is equator‐ward. In austral summer (November–February), the wave occurrence frequency is lower, and the waves mostly propagate pole‐ward. Critical‐layer filtering plays a moderate role in determining the preferential propagation direction in certain months, especially for waves with a smaller observed phase speed (less than typical background winds). The observed wave occurrence and preferential propagation direction are related to the locations of convection activities nearby and their relative distance to ALO. However, direct wave generations are less likely due to the large distance between the ALO and convective sources. Other mechanisms such as secondary wave generation and possible ducted propagation should be considered. The estimated mean momentum fluxes have typical values of a few m2 s−2
    more » « less
  2. Perfluorocarbon nanodroplets (PFCnDs) are ultrasound contrast agents that phase-transition from liquid nanodroplets to gas microbubbles when activated by laser irradiation or insonated with an ultrasound pulse. The dynamics of PFCnDs can vary drastically depending on the nanodroplet composition, including the lipid shell properties. In this paper, we investigate the effect of varying the ratio of PEGylated to non-PEGylated phospholipids in the outer shell of PFCnDs on the acoustic nanodroplet vaporization (liquid to gas phase transition) and inertial cavitation (rapid collapse of the vaporized nanodroplets) dynamics in vitro when insonated with focused ultrasound. Nanodroplets with a high concentration of PEGylated lipids had larger diameters and exhibited greater variance in size distribution compared to nanodroplets with lower proportions of PEGylated lipids in the lipid shell. PFCnDs with a lipid shell composed of 50:50 PEGylated to non-PEGylated lipids yielded the highest B-mode image intensity and duration, as well as the greatest pressure difference between acoustic droplet vaporization onset and inertial cavitation onset. We demonstrate that slight changes in lipid shell composition of PFCnDs can significantly impact droplet phase transitioning and inertial cavitation dynamics. These findings can help guide researchers to fabricate PFCnDs with optimized compositions for their specific applications. 
    more » « less
  3. Diffuse midline gliomas (DMGs), including diffuse intrinsic pontine glioma, have among the highest mortality rates of all childhood cancers, despite recent advancements in cancer therapeutics. This is partly because, unlike some CNS tumors, the blood-brain barrier (BBB) of DMG tumor vessels remains intact. The BBB prevents the permeation of many molecular therapies into the brain parenchyma, where the cancer cells reside. Focused ultrasound (FUS) with microbubbles has recently emerged as an innovative and exciting technology that non-invasively permeabilizes the BBB in a small focal region with millimeter precision. In this review, current treatment methods and biological barriers to treating DMGs are discussed. State-of-the-art FUS-mediated BBB opening is then examined, with a focus on the effects of various ultrasound parameters and the treatment of DMGs. 
    more » « less
  4. Abstract This paper describes a new method for estimating anisotropic mechanical properties of fibrous soft tissue by imaging shear waves induced by focused ultrasound (FUS) and analyzing their direction-dependent speeds. Fibrous materials with a single, dominant fiber direction may exhibit anisotropy in both shear and tensile moduli, reflecting differences in the response of the material when loads are applied in different directions. The speeds of shear waves in such materials depend on the propagation and polarization directions of the waves relative to the dominant fiber direction. In this study, shear waves were induced in muscle tissue (chicken breast) ex vivo by harmonically oscillating the amplitude of an ultrasound beam focused in a cylindrical tissue sample. The orientation of the fiber direction relative to the excitation direction was varied by rotating the sample. Magnetic resonance elastography (MRE) was used to visualize and measure the full 3D displacement field due to the ultrasound-induced shear waves. The phase gradient (PG) of radially propagating “slow” and “fast” shear waves provided local estimates of their respective wave speeds and directions. The equations for the speeds of these waves in an incompressible, transversely isotropic (TI), linear elastic material were fitted to measurements to estimate the shear and tensile moduli of the material. The combination of focused ultrasound and MR imaging allows noninvasive, but comprehensive, characterization of anisotropic soft tissue. 
    more » « less
  5. Objective: Focused ultrasound(FUS)canmodulateneuronalactivitybydepolarizationorhyperpolarization. Although FUS-evokeddepolarizationhasbeenstudiedextensively,themechanismsunderlyingFUS-evoked hyperpolarization (FUSH)havereceivedlittleattention.Inthestudydescribedhere,wedevelopedaprocedure using FUStoselectivelyhyperpolarizemotoraxonsincrayfish. Asapreviousstudyhadreportedthattheseaxons express mechano-andthermosensitivetwo-poredomainpotassium(K2P)channels,wetestedthehypothesisthat K2P channelsunderlieFUSH. Methods: Intracellular recordingsfromamotoraxonandamuscle fiber wereobtainedsimultaneouslyfromthe crayfish openerneuromuscularpreparation.FUSHwasexaminedwhileK2Pchannelactivitiesweremodulated by varyingtemperatureorbyK2Pchannelblockers. Results: FUSH intheaxonsdidnotexhibitacoherenttemperaturedependence,consistentwithpredictedK2P channel behavior,althoughchangesintherestingmembranepotentialofthesameaxonsindicatedwell-behaved K2P channeltemperaturedependence.Thesameconclusionwassupportedbypharmacologicaldata;namely, FUSH wasnotsuppressedbyK2Pchannelblockers.ComparisonbetweentheFUS-evokedresponsesrecordedin motor axonsandmuscle fibers revealedthatthelatterexhibitedverylittleFUSH,indicatingthattheFUSHwas specific totheaxons. Conclusion: It isnotlikelythatK2PchannelsaretheunderlyingmechanismforFUSHinmotoraxons.Alternative mechanisms suchassonophoreandaxon-specific potassiumchannelswereconsidered.Althoughthesonophore hypothesis couldaccountforelectrophysiologicalfeaturesofaxonalrecordings,itisnotconsistentwiththelack of FUSHinmuscle fibers. Anaxon-specific andmechanosensitivepotassiumchannelisalsoapossible explanation. 
    more » « less