Tomography is widely used in medical imaging or industrial non-destructive testing applications. One costly and time consuming operation in any form of tomography is the process of data acquisition where a large number of measurements are made and collected data is used for image reconstruction. Data acquisition can slow down tomography to the point that the scanner cannot catch up with the speed of changes in the medium under test. By optimizing the information content of each measurement, we can reduce the number of measurements needed to achieve the target precision. Development of algorithms to optimize the information content of tomography measurements is the main goal of this article. Here, the dynamics of the medium and tomography measurements are formulated in the form of a Kalman estimation filter. A mathematical algorithm is developed to compute the optimal measurement matrix which minimizes the uncertainty left in the estimation of the distribution the tomography scanner is reconstructing. Results, as presented in the paper, show noticeable improvement is the quality of generated images when the medium is scanned by optimal measurements instead of traditional raster or random scanning protocols. 
                        more » 
                        « less   
                    
                            
                            Optimal data acquisition in tomography
                        
                    
    
            In tomography, three-dimensional images of a medium are reconstructed from a set of two-dimensional projections. Each projection is the result of a measurement made by the scanner via radiating some form of energy and collecting the scattered field after interacting with the medium. The information content of these measurements is not equal, and one projection can be more informative than others. By choosing the most informative measurement at every step of scanning, an optimal tomography system can maximize the speed of data acquisition and temporal resolution of acquired images, reducing the operation cost and exposure to possible harmful radiations. The aim of this paper is to introduce mathematical algorithms that can be used to design measurements with optimal information content when imaging static or dynamically evolving objects. 
        more » 
        « less   
        
    
                            - Award ID(s):
- 2154267
- PAR ID:
- 10477319
- Publisher / Repository:
- Optical Society of America
- Date Published:
- Journal Name:
- Journal of the Optical Society of America A
- Volume:
- 40
- Issue:
- 12
- ISSN:
- 1084-7529; JOAOD6
- Format(s):
- Medium: X Size: Article No. 2259
- Size(s):
- Article No. 2259
- Sponsoring Org:
- National Science Foundation
More Like this
- 
            
- 
            Stimulated Raman projection tomography is a label-free volumetric chemical imaging technology allowing three-dimensional (3D) reconstruction of chemical distribution in a biological sample from the angle-dependent stimulated Raman scattering projection images. However, the projection image acquisition process requires rotating the sample contained in a capillary glass held by a complicated sample rotation stage, limiting the volumetric imaging speed, and inhibiting the study of living samples. Here, we report a tilt-angle stimulated Raman projection tomography (TSPRT) system which acquires angle-dependent projection images by utilizing tilt-angle beams to image the sample from different azimuth angles sequentially. The TSRPT system, which is free of sample rotation, enables rapid scanning of different views by a tailor-designed four-galvo-mirror scanning system. We present the design of the optical system, the theory, and calibration procedure for chemical tomographic reconstruction. 3D vibrational images of polystyrene beads and C. elegans are demonstrated in the C-H vibrational region.more » « less
- 
            null (Ed.)Hyperspectral three-dimensional (3D) imaging can provide both 3D structural and functional information of a specimen. The imaging throughput is typically very low due to the requirement of scanning mechanisms for different depths and wavelengths. Here we demonstrate hyperspectral 3D imaging using Snapshot projection optical tomography (SPOT) and Fourier-transform spectroscopy (FTS). SPOT allows us to instantaneously acquire the projection images corresponding to different viewing angles, while FTS allows us to perform hyperspectral imaging at high spectral resolution. Using fluorescent beads and sunflower pollens, we demonstrate the imaging performance of the developed system.more » « less
- 
            Coded aperture X-ray computed tomography is a computational imaging technique capable of reconstructing inner structures of an object from a reduced set of X-ray projection measurements. Coded apertures are placed in front of the X-ray sources from different views and thus significantly reduce the radiation dose. This paper introduces coded aperture X-ray computed tomography for robotic X-ray systems which offer positioning flexibility. While single coded-aperture 3D tomography was recently introduced for standard trajectory CT scanning, it is shown that significant gains in imaging performance can be attained by simple modifications in the CT scanning trajectories enabled by emerging dual robotic CT systems. In particular, the subject is fixed on a plane and the CT system uniformly rotates around ther −axis which is misaligned with the coordinate axes. A single stationary coded aperture is placed on front of the robotic X-ray source above the plane and the corresponding X-ray projections are measured by a two-dimensional detector on the second arm of the robotic system. The compressive measurements with misalignment enable the reconstruction of high-resolution three-dimensional volumetric images from the low-resolution coded projections on the detector at a sub-sampling rate. An efficient algorithm is proposed to generate the rotation matrix with two basic sub-matrices and thus the forward model is formulated. The stationary coded aperture is designed based on the Pearson product-moment correlation coefficient analysis and the direct binary search algorithm is used to obtain the optimized coded aperture. Simulations using simulated datasets show significant gains in reconstruction performance compared to conventional coded aperture CT systems.more » « less
- 
            Optical projection tomography (OPT) is a three-dimensional (3D) fluorescence imaging technique, in which projection images are acquired for varying orientations of a sample using a large depth of field. OPT is typically applied to a millimeter-sized specimen, because the rotation of a microscopic specimen is challenging and not compatible with live cell imaging. In this Letter, we demonstrate fluorescence optical tomography of a microscopic specimen by laterally translating the tube lens of a wide-field optical microscope, which allows for high-resolution OPT without rotating the sample. The cost is the reduction of the field of view to about halfway along the direction of the tube lens translation. Using bovine pulmonary artery endothelial cells and 0.1 µm beads, we compare the 3D imaging performance of the proposed method with that of the conventional objective-focus scan method.more » « less
 An official website of the United States government
An official website of the United States government 
				
			 
					 
					
