Title: Time series of in situ Uv-Vis absorbance spectra and high-frequency predictions of total and soluble Fe and Mn concentrations measured at multiple depths in Falling Creek Reservoir (Vinton, VA, USA) in 2020 and 2021
High-frequency measurements of light absorbance were collected at multiple depths in Falling Creek Reservoir (FCR; Vinton, VA, USA) using a s::can Spectrolyser UV-Visible spectrophotometer coupled with a multiplexor pumping system. The system pumps water samples from individual depths into a flow-through cuvette where the UV-vis absorbance spectra of the sample are measured by the spectrophotometer. The system used in our study collected measurements of light absorbance every 2.5 nm wavelengths from 200 nm to 732.5 nm (optical path length of 10 mm) approximately at an hourly time step for seven monitoring depths in the reservoir. Data was collected during two periods; the first deployment (16 October to 9 November 2020) was to observe changes in Fe and Mn concentrations before, during, and after reservoir fall turnover and the second deployment (26 May to 21 June 2021) was to observe the effects of engineered hypolimnetic oxygenation on Fe and Mn concentrations. Partial least squares regression models were developed to generate predictions of total and soluble Fe and Mn concentrations based on the correlation between absorbance spectra and sampling data.  more » « less
Award ID(s):
1933016 1753639 1933102
PAR ID:
10478778
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
Environmental Data Initiative
Date Published:
Edition / Version:
1
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Dissolved organic matter (DOM) impacts the structure and function of aquatic ecosystems. DOM absorbs light in the UV and visible (UV–Vis) wavelengths, thus impacting light attenuation. Because absorption by DOM depends on its composition, UV–Vis absorbance is used to constrain DOM composition, source, and amount. Ferric iron, Fe(III), also absorbs in the UV–Vis; when Fe(III) is present, DOM-attributed absorbance is overestimated. Here, we explore how differing behavior of DOM and Fe(III) at the catchment scale impacts UV–Vis absorbance and evaluate how system-specific variability impacts the effectiveness of existing Fe(III) correction factors in a temperate watershed. We sampled five sites in the Connecticut River mainstem bi-weekly for ~ 1.5 years, and seven sites in the Connecticut River watershed once during the summer 2019. We utilized size fractionation to isolate the impact of DOM and Fe(III) on absorbance and show that variable contributions of Fe(III) to absorbance at 254 nm (a 254 ) and 412 nm (a 412 ) by size fraction complicates correction for Fe(III). We demonstrate that the overestimation of DOM-attributed absorbance by Fe(III) is correlated to the Fe(III):dissolved organic carbon concentration ratio; thus, overestimation can be high even when Fe(III) is low. a 254 overestimation is highly variable even within a single system, but can be as high as 53%. Finally, we illustrate that UV-Vis overestimation might impart bias to seasonal, discharge, and land-use trends in DOM quality. Together, these findings argue that Fe(III) should be measured in tandem with UV–Vis absorbance for estimates of CDOM composition or amount. 
    more » « less
  2. Sediment traps were deployed to assess the mass and composition (iron, manganese, total organic carbon, and total nitrogen) of settling particulates in the water column of two drinking water reservoirs—Beaverdam Reservoir and Falling Creek Reservoir, both located in Vinton, Virginia, USA. Sediment traps were deployed at two depths in each reservoir to capture both epilimnetic and hypolimnetic (total) sediment flux. The particulates were collected from the traps approximately fortnightly from April to December from 2018 to 2022, then filtered, dried, and analyzed for either iron and manganese or total organic carbon and total nitrogen. Beaverdam and Falling Creek are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia. The sediment trap dataset consists of logs detailing the sample filtering process, the mass of dried particulates from each filter, and the raw concentration data for iron (Fe) and manganese (Mn), total organic carbon (TOC) and total nitrogen (TN). The final products are the calculated downward fluxes of solid Fe, Mn, TOC and TN during the deployment periods. 
    more » « less
  3. Haasch, Richard; Graham, Dan; Podraza, Nikolas; Shard, Alexander (Ed.)
    Spectroscopic ellipsometry and ultraviolet-visible (UV-VIS) spectrometry were utilized to study the optical properties of ferroelectric lead lanthanum zirconate titanate (PLZT) films. These films were deposited on platinized silicon [Si(100)/ SiO2/TiO2/Pt(111)] substrates using the chemical solution deposition method. Films were annealed at two different temperatures (650 and 750 °C) using rapid thermal annealing. Shimadzu UV-1800 UV-VIS spectrophotometer with a resolution of 1 nm was used to measure the reflectance data in the spectral range of 300–1000 nm with a step size of 1 nm. The bandgap values were determined from the reflectance spectra using appropriate equations. A J.A. Woollam RC2 small spot spectroscopic ellipsometer was used to obtain the change in amplitude (Ψ) and phase (Δ) of polarized light upon reflection from the film surface. The spectra were recorded in the wavelength range of 210–1500 nm at an incident angle of 65°. Refractive index (n) and extinction coefficient (k) were obtained by fitting the spectra (Ψ, Δ) with the appropriate models. No significant changes were observed in the optical constants of PLZT films annealed at 650 and 750 °C. The optical transparency and the strong absorption in the ultraviolet (UV) region of PLZT films make them an attractive material for optoelectronic and UV sensing applications. 
    more » « less
  4. Sediment traps were deployed to assess the mass and composition (lithium, sodium, magnesium, aluminum, potassium, calcium, iron, manganese, copper, strontium, barium, total organic carbon, and total nitrogen) of settling particulates in the water column of two drinking water reservoirs—Beaverdam Reservoir and Falling Creek Reservoir, both located in Vinton, Virginia, USA. Sediment traps were deployed at two depths in each reservoir to capture both epilimnetic and hypolimnetic (total) sediment flux. The particulates were collected from the traps approximately fortnightly from April to December from 2018 to 2023, then filtered, dried, and analyzed for lithium, sodium, magnesium, aluminum, potassium, calcium, iron, manganese, copper, strontium, and barium (2018 to 2023) and total organic carbon and total nitrogen (2018 to 2022, due to instrument repairs). Beaverdam and Falling Creek are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia. The sediment trap dataset consists of logs detailing the sample filtering process, the mass of dried particulates from each filter, and the raw concentration data for lithium (Li), sodium (Na), magnesium (Mg), aluminum (Al), potassium (K), calcium (Ca), iron (Fe), manganese (Mn), copper (Cu), strontium (Sr), barium (Ba), total organic carbon (TOC) and total nitrogen (TN). The final products are the calculated downward fluxes of solid Li, Na, Mg, Al, K, Ca, Fe, Mn, Cu, Sr, Ba, TOC, and TN during the aforementioned deployment periods. 
    more » « less
  5. This manuscript describes the first application of ultrafast-laser-absorption spectroscopy (ULAS) to characterizing high-pressure (up to 40 bar), multi-phase combustion gases. Single-shot measurements of temperature and CO were acquired at 5 kHz in AP-HTPB propellant flames with and without aluminum. An ultrafast light source was used to produce broadband pulses of light near 4.96 𝜇m at a repetition rate of 5 kHz and a high-speed mid-infrared imaging spectrometer was used to image the pulses across an 86 nm bandwidth with a spectral resolution of 0.7 nm. Measurements of temperature and CO concentration were obtained by least-squares fitting simulated absorbance spectra of CO to measured spectra. A system of corrective optics was used to diminish the e˙ect of beam steering during high-pressure experiments, greatly increasing the pressure capabilities of the diagnostic. The diagnostic was used to characterize AP-HTPB propellant flames in an argon bath gas at pressures of 1, 10, 20, and 40 bar. An aluminized AP-HTPB propellant was also characterized at 10 and 20 bar to demonstrate that ULAS can provide high-fidelity measurements in particulate-laden flames. The results demonstrate that ULAS is capable of providing single-shot temperature and species measurements at high pressures with 1-𝜎 precisions less than 1.1% and 3% for temperature and species respectively, despite non-absorbing transmission losses in excess of 90%. 