Though the rabbit is a common animal model in musculoskeletal research, there are very limited data reported on healthy rabbit biomechanics. Our objective was to quantify the normative hindlimb biomechanics (kinematics and kinetics) of six New Zealand White rabbits (three male, three female) during the stance phase of gait. We measured biomechanics by synchronously recording sagittal plane motion and ground contact pressure using a video camera and pressure-sensitive mat, respectively. Both foot angle ( i.e ., angle between foot and ground) and ankle angle curves were unimodal. The maximum ankle dorsiflexion angle was 66.4 ± 13.4° (mean ± standard deviation across rabbits) and occurred at 38% stance, while the maximum ankle plantarflexion angle was 137.2 ± 4.8° at toe-off (neutral ankle angle = 90 degrees). Minimum and maximum foot angles were 17.2 ± 6.3° at 10% stance and 123.3 ± 3.6° at toe-off, respectively. The maximum peak plantar pressure and plantar contact area were 21.7 ± 4.6% BW/cm 2 and 7.4 ± 0.8 cm 2 respectively. The maximum net vertical ground reaction force and vertical impulse, averaged across rabbits, were 44.0 ± 10.6% BW and 10.9 ± 3.7% BW∙s, respectively. Stance duration (0.40 ± 0.15 s) was statistically significantly correlated ( p < 0.05) with vertical impulse (Spearman’s ρ = 0.76), minimum foot angle ( ρ = −0.58), plantar contact length ( ρ = 0.52), maximum foot angle ( ρ = 0.41), and minimum foot angle ( ρ = −0.30). Our study confirmed that rabbits exhibit a digitigrade gait pattern during locomotion. Future studies can reference our data to quantify the extent to which clinical interventions affect rabbit biomechanics.more » « less
-
null (Ed.)Foot drop is the inability to dorsiflex the ankle (raise the toes) due to neuromuscular impairment, and this common condition can cause trips and falls. Current treatments for chronic foot drop provide dorsiflexion support, but they either impede ankle push off or are not suitable for all patients. Powered ankle-foot orthosis (AFO) can counteract foot drop without these drawbacks, but they are heavy and bulky and have short battery life. To counteract foot drop without the drawbacks of current treatments or powered AFO, we designed and built an AFO powered by dielectric elastomer actuators (DEAs), a type of artificial muscle technology. This paper presents our design and the results of benchtop testing. We found that the DEA AFO can provide 49 % of the dorsiflexion support necessary to raise the foot. Further, charging the DEAs reduced the effort that would be required for plantarflexion compared to that with passive DEA behavior, and this operation could be powered for 7000 steps or more in actual operation. DEAs are a promising approach for building an AFO that counteracts foot drop without impeding plantarflexion, and they may prove useful for other powered prosthesis and orthosis designs.more » « less
-
Abstract Background Ankle-foot orthoses (AFOs) are commonly used by children with cerebral palsy (CP), but traditional solutions are unable to address the heterogeneity and evolving needs amongst children with CP. One key limitation lies in the inability of current passive devices to customize the torque–angle relationship, which is essential to adapt the support to the specific individual needs. Powered alternatives can provide customized behavior, but often face challenges with reliability, weight, and cost. Overall, clinicians find certain barriers that hinder their prescription. In recent work, the Variable Stiffness Orthosis (VSO) was developed, enabling stiffness customization without the need for motors or sophisticated control.
Methods This work evaluates a pediatric version of the VSO (inGAIT-VSO) by investigating its impact on the walking performance of children with CP and its potential to be used as a tool for assessing the effect of variable stiffness on pathological gait. Data was collected for three typical developing (TD) children and six pediatric participants with CP over two sessions involving walking/balance tasks and questionnaires.
Results The sensors of the inGAIT-VSO provided useful information to assess the impact of the device. Increasing the stiffness of the inGAIT-VSO significantly reduced participants’ dorsiflexion and plantarflexion. Despite reduced range of motion, the peak restoring torque increased with stiffness. Overall the participants’ gait pattern was altered by reducing crouch gait, preventing drop-foot and supporting body weight. Participants with CP exhibited significantly lower (p < 0.05) physiological cost when walking with the inGAIT-VSO compared to normal condition (own AFO or shoes only). Generally, the device did not impair walking and balance of the participants compared to normal conditions. According to the questionnaire results, the inGAIT-VSO was easy to use and participants reported positive experiences.
Conclusion The inGAIT-VSO stiffnesses significantly affected participants’ plantarflexion and dorsiflexion and yielded objective data regarding walking performance in pathological gait (e.g. ankle angle, exerted torque and restored assistive energy). These effects were captured by the sensors integrated in the device without using external equipment. The inGAIT-VSO shows promise for customizing AFO stiffness and aiding clinicians in selecting a personalized stiffness based on objective metrics.
-
null (Ed.)Transfemoral amputee gait often exhibits compensations due to the lack of ankle push-off power and control over swing foot position using passive prostheses. Powered prostheses can restore this functionality, but their effects on compensatory behaviors, specifically at the residual hip, are not well understood. This paper investigates residual hip compensations through walking experiments with three transfemoral amputees using a low-impedance powered knee-ankle prosthesis compared to their day-to-day passive prosthesis. The powered prosthesis used impedance control during stance for compliant interaction with the ground, a time-based push-off controller to deliver high torque and power, and phase-based trajectory tracking during swing to provide user control over foot placement. Experiments show that when subjects utilized the powered ankle push-off, less mechanical pull-off power was required from the residual hip to progress the limb forward. Overall positive work at the residual hip was reduced for 2 of 3 subjects, and negative work was reduced for all subjects. Moreover, all subjects displayed increased step length, increased propulsive impulses on the prosthetic side, and improved impulse symmetries. Hip circumduction improved for subjects who had previously exhibited this compensation on their passive prosthesis. These improvements in gait, especially reduced residual hip power and work, have the potential to reduce fatigue and overuse injuries in persons with transfemoral amputation.more » « less
-
A novel wearable solution using soft robotic sensors (SRS) has been investigated to model foot-ankle kinematics during gait cycles. The capacitance of SRS related to foot-ankle basic movements was quantified during the gait movements of 20 participants on a flat surface as well as a cross-sloped surface. In order to evaluate the power of SRS in modeling foot-ankle kinematics, three-dimensional (3D) motion capture data was also collected for analyzing gait movement. Three different approaches were employed to quantify the relationship between the SRS and the 3D motion capture system, including multivariable linear regression, an artificial neural network (ANN), and a time-series long short-term memory (LSTM) network. Models were compared based on the root mean squared error (RMSE) of the prediction of the joint angle of the foot in the sagittal and frontal plane, collected from the motion capture system. There was not a significant difference between the error rates of the three different models. The ANN resulted in an average RMSE of 3.63, being slightly more successful in comparison to the average RMSE values of 3.94 and 3.98 resulting from multivariable linear regression and LSTM, respectively. The low error rate of the models revealed the high performance of SRS in capturing foot-ankle kinematics during the human gait cycle.more » « less