skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study
Abstract. Accurate airborne aerosol instrumentation is required to determine thespatial distribution of ambient aerosol particles, particularly when dealingwith the complex vertical profiles and horizontal variations of atmosphericaerosols. A versatile water-based condensation particle counter (vWCPC) hasbeen developed to provide aerosol concentration measurements under variousenvironments with the advantage of reducing the health and safety concernsassociated with using butanol or other chemicals as the working fluid.However, the airborne deployment of vWCPCs is relatively limited due to thelack of characterization of vWCPC performance at reduced pressures. Giventhe complex combinations of operating parameters in vWCPCs, modeling studieshave advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flowvWCPC using COMSOL Multiphysics® simulation coupled withMATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI,Shoreview, MN, USA). Our simulation determined the performance of particleactivation and droplet growth in the vWCPC growth tube, including thesupersaturation, Dp,kel,0 (smallest size of particle that canbe activated), Dp,kel,50 (particle size activated with 50 %efficiency) profile, and final growth particle size Dd underwide operating temperatures, inlet pressures P (30–101 kPa), and growthtube geometry (diameter D and initiator length Lini). Theeffect of inlet pressure and conditioner temperature on vWCPC 3789performance was also examined and compared with laboratory experiments. TheCOMSOL simulation result showed that increasing the temperature difference(ΔT) between conditioner temperature Tcon andinitiator Tini will reduce Dp,kel,0 and thecut-off size Dp,kel,50 of the vWCPC. In addition, loweringthe temperature midpoint(Tmid=Tcon+Tini2) increasesthe supersaturation and slightly decreases the Dp,kel. Thedroplet size at the end of the growth tube is not significantly dependent onraising or lowering the temperature midpoint but significantly decreases atreduced inlet pressure, which indirectly alters the vWCPC empirical cut-offsize. Our study shows that the current simulated growth tube geometry (D=6.3 mm and Lini=30 mm) is an optimized choice forcurrent vWCPC flow and temperature settings. The current simulation can morerealistically represent the Dp,kel for 7 nm vWCPC and alsoachieved good agreement with the 2 nm setting. Using the new simulationapproach, we provide an optimized operation setting for the 7 nm setting.This study will guide further vWCPC performance optimization forapplications requiring precise particle detection and atmospheric aerosolmonitoring.  more » « less
Award ID(s):
2132655
PAR ID:
10492885
Author(s) / Creator(s):
; ; ; ; ; ;
Publisher / Repository:
Copernicus Publications
Date Published:
Journal Name:
Atmospheric Measurement Techniques
Volume:
16
Issue:
17
ISSN:
1867-8548
Page Range / eLocation ID:
3973 to 3986
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract. Particle size measurement in the low nanometer regime is of great importance to the study of cloud condensation nuclei formation and to better understand aerosol–cloud interactions. Here we present the design, modeling, and experimental characterization of the nano-scanning electrical mobility spectrometer (nSEMS), a recently developed instrument that probes particle physical properties in the 1.5–25 nm range. The nSEMS consists of a novel differential mobility analyzer and a two-stage condensation particle counter (CPC). The mobility analyzer, a radial opposed-migration ion and aerosol classifier (ROMIAC), can classify nanometer-sized particles with minimal degradation of its resolution and diffusional losses. The ROMIAC operates on a dual high-voltage supply with fast polarity-switching capability to minimize sensitivity to variations in the chemical nature of the ions used to charge the aerosol. Particles transmitted through the mobility analyzer are measured using a two-stage CPC. They are first activated in a fast-mixing diethylene glycol (DEG) stage before being counted by a second detection stage, an ADI MAGIC™ water-based CPC. The transfer function of the integrated instrument is derived from both finite-element modeling and experimental characterization. The nSEMS performance has been evaluated during measurement of transient nucleation and growth events in the CLOUD atmospheric chamber at CERN. We show that the nSEMS can provide high-time- and size-resolution measurement of nanoparticles and can capture the critical aerosol dynamics of newly formed atmospheric particles. Using a soft x-ray bipolar ion source in a compact housing designed to optimize both nanoparticle charging and transmission efficiency as a charge conditioner, the nSEMS has enabled measurement of the contributions of both neutral and ion-mediated nucleation to new particle formation. 
    more » « less
  2. Abstract. Flow tube reactors are often used to study aerosolkinetics. The goal of this study is to investigate how to best representcomplex growth kinetics of ultrafine particles within a flow tube reactorwhen the chemical processes causing particle growth are unknown. In atypical flow tube experiment, one measures the inlet and outlet particlesize distributions to give a time-averaged measure of growth, which maybe difficult to interpret if the growth kinetics change as particles transitthrough the flow tube. In this work, we simulate particle growth forsecondary organic aerosol (SOA) formation that incorporates both surface-and volume-limited chemical processes to illustrate how complex growthkinetics inside a flow tube can arise. We then develop and assess a methodto account for complex growth kinetics when the chemical processes drivingthe kinetics are not known. Diameter growth of particles is represented by agrowth factor (GF), defined as the fraction of products from oxidation ofthe volatile organic compound (VOC) precursors that grow particles during aspecific time period. Defined in this way, GF is the sum of all non-volatileproducts that condensationally grow particles plus a portion of semi-volatilemolecules that react on or in the particle to give non-volatile products thatremain in the particle over the investigated time frame. With respect toflow tube measurements, GF is independent of wall loss and condensationsink, which influence particle growth kinetics and can vary from experimentto experiment. GF is shown to change as a function of time within the flowtube and is sensitive to factors that affect growth such as gas-phase mixingratios of the precursors and the presence of aerosol liquid water (ALW) onthe surface or in the volume of the particle. A method to calculate GF from theoutlet-minus-inlet particle diameter change in a flow tube experiment ispresented and shown to accurately match GFs from simulations of SOAformation. 
    more » « less
  3. RationaleIn droplet‐assisted ionization (DAI), intact molecular ions are generated from molecules in aerosol droplets by passing the droplets through a temperature‐controlled capillary inlet. Ion formation is explored through the effects of analyte mass flow, droplet solvent composition, and capillary temperature on ion signal intensity. MethodsA Waters SYNAPT G2‐S is adapted for DAI by reconfiguring the inlet with a temperature‐controlled capillary. Droplets are generated by atomization of a solution containing analyte and then sampled through the inlet. If desired, solvent can be removed from the droplets prior to analysis by sending the aerosol through a series of diffusion dryers. Size distributions of the dried aerosols allow the mass flow of analyte into the inlet to be determined. ResultsAnalyte signal intensities are orders of magnitude higher from droplets containing a protic solvent (water) than an aprotic solvent (acetonitrile). The highest signal intensities for DAI are obtained with inlet temperatures above 500°C, though the optimum temperature is analyte dependent. At elevated temperatures, droplets are thought to undergo rapid solvent evaporation and bursting to produce ions. The lowest signal intensities are generally obtained in the 100–350°C range, where slow solvent evaporation is thought to inhibit ion formation. As the temperature decreases from 100°C down to 25°C, the signal intensity increases significantly. When 3‐nitrobenzonitrile, a common matrix for solid‐state matrix‐assisted ionization (MAI), is added to droplets consisting of 50/50 v/v water and acetonitrile, the matrix enhances ion formation to produce a signal intensity comparable to DAI in 100% water. ConclusionsThe results are consistent with other inlet ionization techniques, suggesting that similar ion formation mechanisms are operative. Optimized ion yields (the combined effects of ionization probability and ion transmission) for DAI are currently in the 10−5to 10−6range, which is sufficient for many aerosol applications. 
    more » « less
  4. These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate. 
    more » « less
  5. This dataset includes aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diametr size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate. 
    more » « less