Title: Renewable Convective Heating by the Metallic Strips Heated via a Solar Vacuum Tube
Abstract

The majority of power consumption nowadays goes to heating. Global warming, air and water pollution caused by burning fossil fuel for heating encourage researchers and engineers to focus more on renewable energy. The solar system is one of Earth’s primary sources of clean power. Apart from photovoltaic panels and their effectiveness of power generation contribution, solar heaters are primarily used in different applications to recover heating needs in residential and commercial buildings. This paper focuses on an experimental study to generate heat by a solar system using metallic strips immersed in cement inside a solar vacuum tube. Heat can be transferred from inside the tube to the outside using metallic strips with high conductivity. Then, the metallic strips can be used as a heater to heat water or air in an isolated tank by direct contact between the hot strips and the fluid. In order to keep the system providing heat after the absence of sun’s rays, cement is used in this experiment as a heat repository.

 
more » « less
Award ID(s):
1914751
NSF-PAR ID:
10529374
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
American Society of Mechanical Engineers
Date Published:
ISBN:
978-0-7918-8764-6
Format(s):
Medium: X
Location:
New Orleans, Louisiana, USA
Sponsoring Org:
National Science Foundation
More Like this
  1. Solar thermoelectric generators (STEGs) often require long thermoelectric (TE) legs and efficient cooling at the cold side to increase the temperature difference across TE legs and, thus, the power output. We investigate the effects of direct side-wall air cooling of TE legs on the power output of STEGs fabricated with high aspect-ratio as well as V-shaped p-type and n-type TE couples without additional heat sinks. Wire-type metallic TE materials are welded together to create V-shape TE leg arrays without additional electrodes and attached to a ceramic plate with a solar absorber on top to complete the STEG. The power generation performance of the STEG is investigated with varying wind speed under concentrated solar irradiation. Finite element simulation is performed to further analyze the heat transfer and thermoelectric performance. We find that although sidewall air cooling helps to keep the cold-side temperature cooler in both natural and forced convection regimes, it can also lower the hot-side temperature to reduce the net temperature difference and, thus, the power output and efficiency. Partial thermal insulation of TE couples can further enhance the power output under forced air convection by keeping the hot side temperature higher. The developed STEG achieves a maximum power density of 230 μW/cm2 and a system efficiency of 0.023% under 10 suns with natural convection. The low efficiency was mainly due to the low ZT of the metallic TE materials used and the unoptimized leg length. Our simulation shows that the system efficiency can be improved to 2.8% with state-of-the-art Bi2Te3 alloys at an optimal leg length. 
    more » « less
  2. Abstract

    A thermosyphon-based modular cooling approach offers an energy efficient cooling solution with an increased potential for waste heat recovery. Central to the cooling system is an air-refrigerant finned tube heat exchanger (HX), where air is cooled by evaporating refrigerant. This work builds on a previously published two-dimensional (2D) model for the finned-tube HX by updating and validating the model using in-house experimental data collected from the proposed system using R1233zd(E) as the working fluid. The results show that key system variables such as refrigerant outlet quality, air and refrigerant outlet temperatures, and exchanger duty agree within 20% of their experimental counterparts. The validated model is then used to predict the mean heat transfer coefficient on the refrigerant side for each tube in the direction of airflow, indicating a maximum heat transfer coefficient of nearly 1200 W/(m2 K) for a HX duty of 5.3 kW among the tested cases. The validated model therefore enables accurate predictions of HX performance and provides insights into improving the heat exchange efficiency and the corresponding system performance.

     
    more » « less
  3. Abstract

    An in-rack cooling system connected to an external vapor recompression loop can be an economical solution to harness waste heat recovery in data centers. Validated subsystem-level models of the thermosyphon cooling and recompression loops (evaporator, heat exchangers, compressor, etc.) are needed to predict overall system performance and to perform design optimization based on the operating conditions. This paper specifically focuses on the model of the evaporator, which is a finned-tube heat exchanger incorporated in a thermosyphon cooling loop. The fin-pack is divided into individual segments to analyze the refrigerant and air side heat transfer characteristics. Refrigerant flow in the tubes is modeled as 1-D flow scheme with transport equations solved on a staggered grid. The air side is modeled using differential equations to represent the air temperature and humidity ratio and to predict if moisture removal will occur, in which case the airside heat transfer coefficient is suitably reduced. The louver fins are modeled as individual hexagons and are treated in conjunction with the tube walls. A segment-by-segment approach is utilized for each tube and the heat exchanger geometry is subsequently evaluated from one end to the other, with air property changes considered for each subsequent row of tubes. Model predictions of stream outlet temperature and pressure, refrigerant outlet vapor quality and heat exchanger duty show good agreement when compared against a commercial software.

     
    more » « less
  4. null (Ed.)
    Thermoelectric (TE) cement composite is a new type of TE material. Unlike ordinary cement, TE cement can mutually convert thermal energy to electrical energy due to the addition of carbon fibers, metal oxide nanoparticles, etc. In hot summer or cold winter, the significant temperature difference between indoor and outdoor can be used by TE cement to generate electricity. On the other hand, given power input, the same material can provide cooling/ heating to adjust room temperature. Therefore, TE cement has certain energy-saving potential in the application of building enclosures and energy systems. Its ability to convert different forms of energy and use low-grade energy is conducive to the operation of net-zero buildings. In this study, a novel TE cement composite, MnO2 and graphite enhanced cement, was firstly fabricated. The surface morphology of the composites was analyzed by using the images taken by scanning electron microscopy. The performance indicators of TE materials include the power factor and dimensionless figure of merit ZT The values of five TE properties were measured and calculated by a Physical Property Measurement System at different temperatures. Compared with the cement reinforced by graphite alone, it is confirmed that MnO2 nanoparticles have a positive effect on the enhancement of the TE performance for cement composites. The 5wt.% graphite and 10wt.% MnO2 enhanced cement composite achieves the highest Z.T. of 6.2 × 10-6 at 350 K. 
    more » « less
  5. Abstract

    This work presents the experimental characterization of pool boiling heat transfer enhancement on cylindrical tubes with circumferential micro-channels using saturated water at atmospheric pressure as the working fluid. Three engineered copper tubes with 300 μm, 600 μm and 900 μm fin width and a fixed 400 μm channel width with 410 μm channel depth were machined using CNC. To compare the boiling enhancement on engineered tubes, one plain copper tube was used as the reference heater. The active heating area on the cylindrical tubes had a dimension of 9.5 mm outer diameter and 10.5 mm length. A custom-built cylindrical heater was designed using a nichrome wire coil of 30 AWG with a resistance of 19.57 Ω/inch of coil to provide joule heating to the cylindrical tubes. The electrical wire was insulated from the copper heater using a thin layer of alumina paste. The saturated pool boiling tests up to critical heat flux (CHF) were conducted at atmospheric pressure. While an approximate CHF of ∼70 W/cm2 was achieved for the plain copper tube, the cylindrical tube with microchannel geometry showed a CHF range of 131–144 W/cm2 that corresponds to 87%–100% enhancement as compared to plain cylindrical tube.

     
    more » « less