skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Implant Design and Cervical Spinal Biomechanics and Neurorehabilitation: A Finite Element Investigation
ABSTRACT IntroductionThe cervical spine, pivotal for mobility and overall body function, can be affected by cervical spondylosis, a major contributor to neural disorders. Prevalent in both general and military populations, especially among pilots, cervical spondylosis induces pain and limits spinal capabilities. Anterior Cervical Discectomy and Fusion (ACDF) surgery, proposed by Cloward in the 1950s, is a promising solution for restoring natural cervical curvature. The study objective was to investigate the impacts of ACDF implant design on postsurgical cervical biomechanics and neurorehabilitation outcomes by utilizing a biofield head-neck finite element (FE) platform that can facilitate scenario-specific perturbations of neck muscle activations. This study addresses the critical need to enhance computational models, specifically FE modeling, for ACDF implant design. Materials and MethodsWe utilized a validated head-neck FE model to investigate spine–implant biomechanical interactions. An S-shaped dynamic cage incorporating titanium (Ti) and polyetheretherketone (PEEK) materials was modeled at the C4/C5 level. The loading conditions were carefully designed to mimic helmet-to-helmet impact in American football, providing a realistic and challenging scenario. The analysis included intervertebral joint motion, disk pressure, and implant von Mises stress. ResultsThe PEEK implant demonstrated an increased motion in flexion and lateral bending at the contiguous spinal (C4/C5) level. In flexion, the Ti implant showed a modest 5% difference under 0% activation conditions, while PEEK exhibited a more substantial 14% difference. In bending, PEEK showed a 24% difference under 0% activation conditions, contrasting with Ti’s 17%. The inclusion of the head resulted in an average increase of 18% in neck angle and 14% in C4/C5 angle. Disk pressure was influenced by implant material, muscle activation level, and the presence of the head. Polyetheretherketone exhibited lower stress values at all intervertebral disc levels, with a significant effect at the C6/C7 levels. Muscle activation level significantly influenced disk stress at all levels, with higher activation yielding higher stress. Titanium implant consistently showed higher disk stress values than PEEK, with an orders-of-magnitude difference in von Mises stress. Excluding the head significantly affected disk and implant stress, emphasizing its importance in accurate implant performance simulation. ConclusionsThis study emphasized the use of a biofidelic head-neck model to assess ACDF implant designs. Our results indicated that including neck muscles and head structures improves biomechanical outcome measures. Furthermore, unlike Ti implants, our findings showed that PEEK implants maintain neck motion at the affected level and reduce disk stresses. Practitioners can use this information to enhance postsurgery outcomes and reduce the likelihood of secondary surgeries. Therefore, this study makes an important contribution to computational biomechanics and implant design domains by advancing computational modeling and theoretical knowledge on ACDF–spine interaction dynamics.  more » « less
Award ID(s):
2239110
PAR ID:
10534156
Author(s) / Creator(s):
;
Publisher / Repository:
Oxford University Press
Date Published:
Journal Name:
Military Medicine
Volume:
189
Issue:
Supplement_3
ISSN:
0026-4075
Format(s):
Medium: X Size: p. 791-799
Size(s):
p. 791-799
Sponsoring Org:
National Science Foundation
More Like this
  1. Cervical laminoplasty is a valuable procedure for myelopathy but it is associated with complications such as increased kyphosis. The effect of ligament damage during cervical laminoplasty on biomechanics is not well understood. We developed the C2–C7 cervical spine finite element model and simulated C3–C6 double-door laminoplasty. Three models were created (a) intact, (b) laminoplasty-pre (model assuming that the ligamentum flavum (LF) between C3–C6 was preserved during surgery), and (c) laminoplasty-res (model assuming that the LF between C3–C6 was resected during surgery). The models were subjected to physiological loading, and the range of motion (ROM), intervertebral nucleus stress, and facet contact forces were analyzed under flexion/extension, lateral bending, and axial rotation. The maximum change in ROM was observed under flexion motion. Under flexion, ROM in the laminoplasty-pre model increased by 100.2%, 111.8%, and 98.6% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The ROM in laminoplasty-res further increased by 105.2%, 116.8%, and 101.8% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The maximum stress in the annulus/nucleus was observed under left bending at the C4–C5 segment where an increase of 139.5% and 229.6% compared to the intact model was observed for laminoplasty-pre and laminoplasty-res model, respectively. The highest facet contact forces were observed at C4–C5 under axial rotation, where an increase of 500.7% and 500.7% was observed compared to the intact model for laminoplasty-pre and laminoplasty-res, respectively. The posterior ligaments of the cervical spine play a vital role in restoring/stabilizing the cervical spine. When laminoplasty is performed, the surgeon needs to be careful not to injure the posterior soft tissue, including ligaments such as LF. 
    more » « less
  2. Abstract PurposeThis study aimed to investigate the role of neck muscle activity and neck damping characteristics in traumatic brain injury (TBI) mechanisms. MethodsWe used a previously validated head-neck finite element (FE) model that incorporates various components such as scalp, skull, cerebrospinal fluid, brain, muscles, ligaments, cervical vertebrae, and intervertebral discs. Impact scenarios included a Golf ball impact, NBDL linear acceleration, and Zhang’s linear and rotational accelerations. Three muscle activation strategies (no-activation, low-to-medium, and high activation levels) and two neck damping levels by perturbing intervertebral disc properties (high: hyper-viscoelastic and low: hyper-elastic) strategies were examined. We employed Head Injury Criterion (HIC), Brain Injury Criterion (BrIC), and maximum principal strain (MPS) as TBI measures. ResultsIncreased neck muscle activation consistently reduced the values of all TBI measures in Golf ball impact (HIC: 4%-7%, BrIC: 11%-25%, and MPS (occipital): 27%-50%) and NBDL study (HIC: 64%-69%, BrIC: 3%-9%, and MPS (occipital): 6%-19%) simulations. In Zhang’s study, TBI metric values decreased with the increased muscle activation from no-activation to low-to-medium (HIC: 74%-83%, BrIC: 27%-27%, and MPS (occipital): 60%-90%) and then drastically increased with further increases to the high activation level (HIC: 288%-507%, BrIC: 1%-25%, and MPS (occipital): 23%-305%). Neck damping changes from low to high decreased all values of TBI metrics, particularly in Zhang’s study (up to 40% reductions). ConclusionOur results underscore the pivotal role of neck muscle activation and neck damping in TBI mitigation and holds promise to advance effective TBI prevention and protection strategies for diverse applications. 
    more » « less
  3. null (Ed.)
    A popular posture for using wireless technology is reclined sitting, with the trunk rotated posteriorly to the hips. This position decreases the head’s gravitational moment; however, the head angle relative to the trunk is similar to that of upright sitting when using a tablet in the lap. This study compared cervical extensor musculotendon length changes from neutral among 3 common sitting postures and maximum neck flexion while using a tablet. Twenty-one participants had radiographs taken in neutral, full-flexion, and upright, semireclined, and reclined postures with a tablet in their lap. A biomechanical model was used to calculate subject-specific normalized musculotendon lengths for 27 cervical musculotendon segments. The lower cervical spine was more flexed during reclined sitting, but the skull was more flexed during upright sitting. Normalized musculotendon length increased in the reclined compared with an upright sitting position for the C4-C6/7 (deep) and C2-C6/7 (superficial) multifidi, semispinalis cervicis (C2-C7), and splenius capitis (Skull-C7). The suboccipital ( R 2  = .19–.71) and semispinalis capitis segment length changes were significantly correlated with the Skull-C1 angle (0.24–0.51). A semireclined reading position may be an ideal sitting posture to reduce the head’s gravitational moment arm without overstretching the assessed muscles. 
    more » « less
  4. IntroductionThe correlation between cervical alignment and clinical outcome of total disc replacement (TDR) surgery is arguable. We believe that this conflict exists because the parameters that influence the biomechanics of the cervical spine are not well understood, specifically the effect of TDR on different cervical alignments. Methods:A validated osseo-ligamentous model from C2-C7 was used in this study. The C2-C7 Cobb angle of the base model was modified to represent: lordotic (−10°), straight (0°), and kyphotic (+10°) cervical alignment. The TDR surgery was simulated at the C5-C6 segment. The range of motion (ROM), intradiscal pressure, annular stresses, and facet loads were computed for all the models. Results:The ROM results demonstrated kyphotic alignment after TDR surgery to be the most mobile when compared to intact base model (41% higher in flexion–extension, 51% higher in lateral bending, and 27% higher in axial rotation) followed by straight and lordotic alignment, respectively. The annular stresses for the kyphotic alignment when compared to intact base model were higher at the index level (33% higher in flexion–extension and 48% higher in lateral bending) compared to other alignments. The lordotic model demonstrated higher facet contact forces at the index level (75% higher in extension than kyphotic alignment, 51% higher in lateral bending than kyphotic alignment, and 78% higher in axial rotation than kyphotic alignment) when compared among the three alignment models. Conclusion:Preoperative cervical alignment should be an integral part of surgical planning for TDR surgery as different cervical alignments may significantly alter the postsurgical outcomes. 
    more » « less
  5. Cervical disc implants are conventional surgical treatments for patients with degenerative disc disease, such as cervical myelopathy and radiculopathy. However, the surgeon still must determine the candidacy of cervical disc implants mainly from the findings of diagnostic imaging studies, which can sometimes lead to complications and implant failure. To help address these problems, a new approach was developed to enable surgeons to preview the post-operative effects of an artificial disc implant in a patient-specific fashion prior to surgery. To that end, a robotic replica of a person’s spine was 3D printed, modified to include an artificial disc implant, and outfitted with a soft magnetic sensor array. The aims of this study are threefold: first, to evaluate the potential of a soft magnetic sensor array to detect the location and amplitude of applied loads; second, to use the soft magnetic sensor array in a 3D printed human spine replica to distinguish between five different robotically actuated postures; and third, to compare the efficacy of four different machine learning algorithms to classify the loads, amplitudes, and postures obtained from the first and second aims. Benchtop experiments showed that the soft magnetic sensor array was capable of precisely detecting the location and amplitude of forces, which were successfully classified by four different machine learning algorithms that were compared for their capabilities: Support Vector Machine (SVM), K-Nearest Neighbor (KNN), Random Forest (RF), and Artificial Neural Network (ANN). In particular, the RF and ANN algorithms were able to classify locations of loads applied 3.25 mm apart with 98.39% ± 1.50% and 98.05% ± 1.56% accuracies, respectively. Furthermore, the ANN had an accuracy of 94.46% ± 2.84% to classify the location that a 10 g load was applied. The artificial disc-implanted spine replica was subjected to flexion and extension by a robotic arm. Five different postures of the spine were successfully classified with 100% ± 0.0% accuracy with the ANN using the soft magnetic sensor array. All results indicated that the magnetic sensor array has promising potential to generate data prior to invasive surgeries that could be utilized to preoperatively assess the suitability of a particular intervention for specific patients and to potentially assist the postoperative care of people with cervical disc implants. 
    more » « less