Title: Expanding the Surgical Robotics Community: An Intuitive Sim-to-Real Control Framework for Raven-II with a Budget-Friendly Gamepad Controller
This paper proposes a low-cost interface and refined digital twin for the Raven-II surgical robot. Previous simulations of the Raven-II, e.g. via the Asynchronous Multibody Framework (AMBF), presented salient drawbacks, including control inputs inconsistent with Raven-II software, and lack of stable, high-fidelity physical contact simulations. This work bridges both of these gaps, both (1) enabling robust, simulated contact mechanics for dynamic physical interactions with the Raven-II, and (2) developing a universal input format for both simulated and physical platforms. The method furthermore proposes a low cost, commodity game-controller interface for controlling both virtual and real realizations of Raven-II, thus greatly reducing the barrier to access for Raven-II research and collaboration. Overall, this work aims to eliminate the inconsistencies between simulated and real representations of the Raven-II. Such a development can expand the reach of surgical robotics research. Namely, providing end-to-end transparency between the simulated AMBF and physical Raven-II platforms enables a software testbed previously unavailable, e.g. for training real surgeons, for creating digital synthetic datasets, or for prototyping novel architectures like shared control strategies. Experiments validate this transparency by comparing joint trajectories between digital twin and physical testbed given identical inputs. This work may be extended and incorporated into recent efforts in developing modular or common software infrastructures for both simulation and control of real robotic devices, such as the Collaborative Robotics Toolkit (CRTK).  more » « less
Award ID(s):
2101107
PAR ID:
10552161
Author(s) / Creator(s):
; ; ; ; ; ;
Publisher / Repository:
IEEE 2024 International Symposium on Medical Robotics (ISMR)
Date Published:
ISSN:
2771-9049
ISBN:
979-8-3503-7711-8
Page Range / eLocation ID:
1 to 7
Format(s):
Medium: X
Location:
Atlanta, GA, USA
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Robot-assisted minimally invasive surgery has made a substantial impact in operating rooms over the past few decades with their high dexterity, small tool size, and impact on adoption of minimally invasive techniques. In recent years, intelligence and different levels of surgical robot autonomy have emerged thanks to the medical robotics endeavors at numerous academic institutions and leading surgical robot companies. To accelerate interaction within the research community and prevent repeated development, we propose the Collaborative Robotics Toolkit (CRTK), a common API for the RAVEN-II and da Vinci Research Kit (dVRK) - two open surgical robot platforms installed at more than 40 institutions worldwide. CRTK has broadened to include other robots and devices, including simulated robotic systems and industrial robots. This common API is a community software infrastructure for research and education in cutting edge human-robot collaborative areas such as semi-autonomous teleoperation and medical robotics. This paper presents the concepts, design details and the integration of CRTK with physical robot systems and simulation platforms. 
    more » « less
  2. null (Ed.)
    Robot-assisted minimally invasive surgery has made a substantial impact in operating rooms over the past few decades with their high dexterity, small tool size, and impact on adoption of minimally invasive techniques. In recent years, intelligence and different levels of surgical robot autonomy have emerged thanks to the medical robotics endeavors at numerous academic institutions and leading surgical robot companies. To accelerate interaction within the research community and prevent repeated development, we propose the Collaborative Robotics Toolkit (CRTK), a common API for the RAVEN-II and da Vinci Research Kit (dVRK) - two open surgical robot platforms installed at more than 40 institutions worldwide. CRTK has broadened to include other robots and devices, including simulated robotic systems and industrial robots. This common API is a community software infrastructure for research and education in cutting edge human-robot collaborative areas such as semi-autonomous teleoperation and medical robotics. This paper presents the concepts, design details and the integration of CRTK with physical robot systems and simulation platforms. 
    more » « less
  3. A digital twin (DT) is an interactive, real-time digital representation of a system or a service utilizing onboard sensor data and Internet of Things (IoT) technology to gain a better insight into the physical world. With the increasing complexity of systems and products across many sectors, there is an increasing demand for complex systems optimization. Digital twins vary in complexity and are used for managing the performance, health, and status of a physical system by virtualizing it. The creation of digital twins enabled by Modelbased Systems Engineering (MBSE) has aided in increasing system interconnectivity and simplifying the system optimization process. More specifically, the combination of MBSE languages, tools, and methods has served as a starting point in developing digital twins. This article discusses how MBSE has previously facilitated the development of digital twins across various domains, emphasizing both the benefits and disadvantages of adopting an MBSE enabled digital twin creation. Further, the article expands on how various levels of digital twins were generated via the use of MBSE. An MBSE enabled conceptual framework for developing digital twins is identified that can be used as a research testbed for developing digital twins and optimizing systems and system of systems. Keywords—MBSE, Digital Twin, Digital Shadow, Digital Model, SysML 
    more » « less
  4. The Raven I and the Raven II surgical robots, as open research platforms, have been serving the robotic surgery research community for ten years. The paper 1) briefly presents the Raven I and the Raven II robots, 2) reviews the recent publications that are built upon the Raven robots, aim to be applied to the Raven robots, or are directly compared with the Raven robots, and 3) uses the Raven robots as a case study to discuss the popular research problems in the research community and the trend of robotic surgery study. Instead of being a thorough literature review, this work only reviews the works formally published in the past three years and uses these recent publications to analyze the research interests, the popular open research problems, and opportunities in the topic of robotic surgery. 
    more » « less
  5. null (Ed.)
    Surgical robots have been introduced to operating rooms over the past few decades due to their high sensitivity, small size, and remote controllability. The cable-driven nature of many surgical robots allows the systems to be dexterous and lightweight, with diameters as low as 5mm. However, due to the slack and stretch of the cables and the backlash of the gears, inevitable uncertainties are brought into the kinematics calcu- lation [1]. Since the reported end effector position of surgical robots like RAVEN-II [2] is directly calculated using the motor encoder measurements and forward kinematics, it may contain relatively large error up to 10mm, whereas semi-autonomous functions being introduced into abdominal surgeries require position inaccuracy of at most 1mm. To resolve the problem, a cost-effective, real-time and data-driven pipeline for robot end effector position precision estimation is proposed and tested on RAVEN-II. Analysis shows an improved end effector position error of around 1mm RMS traversing through the entire robot workspace without high-resolution motion tracker. The open source code, data sets, videos, and user guide can be found at //github.com/HaonanPeng/RAVEN Neural Network Estimator. 
    more » « less