skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Single particle tracking reveals through-membrane diffusion of bacteriophage during process disruption of virus filtration
In the biopharmaceutical industry, virus filters are crucial for ensuring the removal of endogenous and adventitious viruses as part of the viral clearance strategy. Although traditionally described as a size-exclusion mechanism, virus retention has a pro-cess-dependent nature where challenging conditions, such as process disruptions, may compromise membrane retention and significantly increase virus filtrate concentrations. The detailed mechanisms underlying this loss of retention are challenging to determine using traditional breakthrough experiments. In this work, single particle tracking and kinetic simulations were employed to connect individual particle behavior to the observed macroscopic losses in virus retention. Our experiments, using fluorescently labeled ΦX174 bacteriophage as a model parvovirus, replicated conditions representative of process disruptions within the Pegasus SV4, a homogeneous polymeric virus filtration membrane. During flow, phage particles retained were trapped within relatively large cavity spaces that had downstream constrictions aligned with the flow direction; the trapped particles were dynamic and exhibited significant intra-cavity motion. Upon flow stoppage, particles escaped from these retention locations rapidly, with approximately 90% of previously trapped particles being remobilized for process dis-ruption time ranging from 2 to 10 minutes, suggesting that local cavity escape had reached saturation at these timescales. Diffusion experiments within the membrane revealed isotropic and Fickian motion, hindered by more than an order of mag-nitude compared to diffusion in unconfined liquid. Despite the reduced mobility within the membrane, the substantial diffusion coefficient of 4.19 ± 0.06 µm²/s indicated that virus particles could travel tortuous but non-retentive pathways through the membrane on length scales equal to or greater than the membrane thickness during a disruption event. A 1D kinetic Monte-Carlo simulation successfully connected single-particle behavior to macroscopically observed virus release, indicating that significant diffusive release into the filtrate can occur even without the resumption of flow. This work provides crucial insights into the retention behavior of homogeneous membranes during periods of disruption, enabling the design of more robust mitigation strategies and filter designs.  more » « less
Award ID(s):
2310832 1841474 2310937 2053118
PAR ID:
10558212
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Elsevier
Date Published:
Journal Name:
Journal of Membrane Science
Volume:
713
Issue:
C
ISSN:
0376-7388
Page Range / eLocation ID:
123380
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Membrane filtration fouling is a very complex process and is determined by many properties such as the membrane internal morphology, membrane pore structure, flow rate and contaminant properties. In a very slow filtration process or during the late stage of filtration, when the flow rate is naturally low and Péclet number is small, particle diffusion is essential and cannot be neglected, while in typical filtration models, especially in moderate and fast filtration process, the main contribution stems from the particle advection. The objectives of this study is to formulate mathematical models that can (i) investigate how filtration process varies under possible effects of particles diffusion; and (ii) describe how membrane morphology evolves and investigate the filtration performance during the filtration process. We also compare the results with the case that diffusion is less important and make a prediction about what kind of membrane filter pore structure should be employed to achieve a particular optimum filtration performance. According to our results, the filtrate and efficiency of particle separation are found to be under the trade-off relationship, and the selection of the membrane properties depends on the requirement of the filtration. 
    more » « less
  2. The performance of virus filters is often determined by the extent of protein fouling, which can affect both filtrate flux and virus retention. However, the mechanisms governing changes in virus retention in the presence of proteins are still not well understood. The objective of this work was to examine the effect of proteins on virus retention by both asymmetric (Viresolve® NFP and Viresolve® Pro) and relatively homogeneous (Ultipor® DV20 and PegasusTM SV4) virus filtration membranes. Experiments were performed with bacteriophage ϕX174 as a model parvovirus and human serum immunoglobulin G (hIgG) as a model protein. The virus retention in 1 g/L hIgG solutions was consistently less than that in a protein-free buffer solution by between 1 to 3 logs for the different virus filters. The virus retention profiles for the two homogeneous membranes were very similar, with the virus retention being highly correlated with the extent of flux decline. Membranes prefouled with hIgG and then challenged with phages also showed much lower virus retention, demonstrating the importance of membrane fouling; the one exception was the Viresolve® Pro membrane, which showed a similar virus retention for the prefouled and pristine membranes. Experiments in which the protein was filtered after the virus challenge demonstrated that hIgG can displace previously captured viruses from within a filter. The magnitude of these effects significantly varied for the different virus filters, likely due to differences in membrane morphology, pore size distribution, and chemistry, providing important insights into the development/application of virus filtration in bioprocessing. 
    more » « less
  3. Protein fouling can significantly reduce the filtrate flux, capacity, and virus retention during processing of plasma- or mammalian cell-derived biopharmaceuticals through virus removal filters. We use focused ion beam (FIB) milling and scanning electron microscopy (SEM) to directly evaluate changes in 3D pore structure in a Viresolve® Pro membrane due to fouling by human serum immunoglobulin G. Protein fouling causes a significant reduction in the membrane porosity, which decreases by approximately 40% in the size-selective region near the exit of the highly asymmetric Viresolve® Pro membrane after the filter is fouled to 90% flux decline. There is a corresponding reduction in the number of small pores by more than a factor of two. Model simulations of flow and particle transport in the protein-fouled membrane are in good agreement with independent experimental measurements of the permeability and location of particle capture. Simulations show an upstream shift in the location of nanoparticle capture (away from the filter exit) by about 0.4 µm for the membrane fouled to 90% flux decline. This is due to pore constriction from protein deposition, highlighting how fouling redistributes flow paths within the membrane. These results demonstrate the capability of using FIB-SEM to directly evaluate the effects of protein fouling on the 3D pore structure in virus removal filters, providing important insights into how protein fouling alters the performance of these highly selective membranes. 
    more » « less
  4. null (Ed.)
    Particle size and settling speed determine the rate of particulate mass transfer from the ocean surface to the sea bed. Turbulent shear in the ocean can act on large, faster-settling flocculated particles to break them into slower-settling primary particles or sub-aggregates. However, it is difficult to understand the disruption behavior of aggregates and their response to varying shear forces due to the complex ocean environment. A study was conducted to simulate the disruption behavior of marine aggregates in the mixed layer of the ocean. The breakup process was investigated by aggregating and disrupting flocs of bentonite clay particles in a rotating and oscillating cylindrical tank 10 cm in diameter filled with salt water. This laboratory tank, which operated based on an extension of Stokes’ second problem inside a cylinder, created laminar oscillating flow superimposed on a constant rotation. This motion allowed the bentonite particles to aggregate near the center of the tank but also exposed large aggregates to high shear forces near the wall. A high-speed camera system was used, along with particle tracking measurements and image processing techniques, to capture the breakup of the large particle aggregates and locate their radial position. The breakup response of large aggregates and the sizes of their daughter particles after breakup were quantified using the facility. The disruption strength of the aggregated particles is presented and discussed relative to their exposure to varying amounts of laminar shear. 
    more » « less
  5. Abstract Virus filtration is a crucial step in ensuring the high levels of viral clearance required in the production of biotherapeutics produced in mammalian cells or derived from human plasma. Previous studies have reported that virus retention is often reduced in the presence of therapeutic proteins due to membrane fouling; however, the underlying mechanisms controlling this behavior are still not well understood. Experimental studies were performed with a single layer of the commercially available dual‐layer PegasusTMSV4 virus removal filter to more easily interpret the experimental results. Bacteriophage ФX174 was used as a model parvovirus, and human immunoglobulin (hIgG) and Bovine Serum Albumin (BSA) were used as model proteins. Data obtained with 5 g/L solutions of hIgG showed more than a 100‐fold reduction in virus retention compared to that in the protein‐free solution. Similar effects were seen with membranes that were pre‐fouled with hIgG and then challenged with ФX174. The experimental data were well‐described using an internal polarization model that accounts for virus capture and accumulation within the virus filter, with the hIgG nearly eliminating the irreversible virus capture while also facilitating the release of previously captured virus. These results provide important insights into the performance and validation of virus removal filters in bioprocessing. 
    more » « less