Title: Speckle-illumination spatial frequency domain imaging with a stereo laparoscope for profile-corrected optical property mapping
Significance: Laparoscopic surgery presents challenges in localizing oncological margins due to poor contrast between healthy and malignant tissues. Optical properties can uniquely identify various tissue types and disease states with high sensitivity and specificity, making it a promising tool for surgical guidance. Although spatial frequency domain imaging (SFDI) effectively measures quantitative optical properties, its deployment in laparoscopy is challenging due to the constrained imaging environment. Thus, there is a need for compact structured illumination techniques to enable accurate, quantitative endogenous contrast in minimally invasive surgery. Aim: We introduce a compact, two-camera laparoscope that incorporates both active stereo depth estimation and speckle-illumination SFDI (si-SFDI) to map profile-corrected, pixel-level absorption (μa), and reduced scattering (μ′s) optical properties in images of tissues with complex geometries. Approach: We used a multimode fiber-coupled 639-nm laser illumination to generate high-contrast speckle patterns on the object. These patterns were imaged through a modified commercial stereo laparoscope for optical property estimation via si-SFDI. Compared with the original si-SFDI work, which required ≥10 images of randomized speckle patterns for accurate optical property estimations, our approach approximates the DC response using a laser speckle reducer (LSR) and consequently requires only two images. In addition, we demonstrate 3D profilometry using active stereo from low-coherence RGB laser flood illumination. Sample topography was then used to correct for measured intensity variations caused by object height and surface angle differences with respect to a calibration phantom. The low-contrast RGB speckle pattern was blurred using an LSR to approximate incoherent white light illumination. We validated profile-corrected si-SFDI against conventional SFDI in phantoms with simple and complex geometries, as well as in a human finger in vivo time-series constriction study. Results: Laparoscopic si-SFDI optical property measurements agreed with conventional SFDI measurements when measuring flat tissue phantoms, exhibiting an error of 6.4% for absorption and 5.8% for reduced scattering. Profile-correction improved the accuracy for measurements of phantoms with complex geometries, particularly for absorption, where it reduced the error by 23.7%. An in vivo finger constriction study further validated laparoscopic si-SFDI, demonstrating an error of 8.2% for absorption and 5.8% for reduced scattering compared with conventional SFDI. Moreover, the observed trends in optical properties due to physiological changes were consistent with previous studies. Conclusions: Our stereo-laparoscopic implementation of si-SFDI provides a simple method to obtain accurate optical property maps through a laparoscope for flat and complex geometries. This has the potential to provide quantitative endogenous contrast for minimally invasive surgical guidance.  more » « less
Award ID(s):
2146333
PAR ID:
10569551
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
SPIE
Date Published:
Journal Name:
Journal of Biomedical Optics
Volume:
30
Issue:
S1
ISSN:
1083-3668
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Photoacoustic imaging has demonstrated recent promise for surgical guidance, enabling visualization of tool tips during surgical and non-surgical interventions. To receive photoacoustic signals, most conventional transducers are rigid, while a flexible array is able to deform and provide complete contact on surfaces with different geometries. In this work, we present photoacoustic images acquired with a flexible array transducer in multiple concave shapes in phantom andex vivobovine liver experiments targeted toward interventional photoacoustic applications. We validate our image reconstruction equations for known sensor geometries with simulated data, and we provide empirical elevation field-of-view, target position, and image quality measurements. The elevation field-of-view was 6.08 mm at a depth of 4 cm and greater than 13 mm at a depth of 5 cm. The target depth agreement with ground truth ranged 98.35-99.69%. The mean lateral and axial target sizes when imaging 600μm-core-diameter optical fibers inserted within the phantoms ranged 0.98-2.14 mm and 1.61-2.24 mm, respectively. The mean ± one standard deviation of lateral and axial target sizes when surrounded by liver tissue were 1.80±0.48 mm and 2.17±0.24 mm, respectively. Contrast, signal-to-noise, and generalized contrast-to-noise ratios ranged 6.92–24.42 dB, 46.50–67.51 dB, and 0.76–1, respectively, within the elevational field-of-view. Results establish the feasibility of implementing photoacoustic-guided surgery with a flexible array transducer. 
    more » « less
  2. Abstract Laparoscopic surgery has a notably high learning curve, hindering typical approaches to training. Due to unique challenges that are not present in open surgery (the hinge effect, small field of view (FoV), lack of depth perception, and small workspace), a surgical resident may be delayed in participating in laparoscopic surgery until later in residency. Having a narrow window to complete highly specialized training can lead to graduates feeling under-prepared for solo practice. Additionally, delayed introduction may expose trainees to fewer than 200 laparoscopic cases. Therefore, there is a need for surgical residents to increase both their caseload and training window without compromising patient safety. This project aims to develop and test a proof-of-concept prototype that uses granular jamming technology to controllably vary the force required to move a laparoscopic tool. By increasing tool resistance, the device helps prevents accidental injury to important nearby anatomical structures such as urinary tract, vasculature, and/or bowel. Increasing the safety of laparoscopic surgery would allow residents to begin their training earlier, gaining exposure and confidence. A device to adjust tool resistance has benefits to the experienced surgeon as well – surgeries require continuous tool adjustment and tension, resulting in fatigue. Increasing tool resistance can assist surgeons in situations requiring continuous tension and can also provide safety against sudden movements. This investigational device was prototyped using SolidWorks CAD software, then 3D printed and assessed with a laparoscopic box trainer. 
    more » « less
  3. Laser speckle contrast imaging is widely used in clinical studies to monitor blood flow distribution. Speckle contrast tomography, similar to diffuse optical tomography, extends speckle contrast imaging to provide deep tissue blood flow information. However, the current speckle contrast tomography techniques suffer from poor spatial resolution and involve both computation and memory intensive reconstruction algorithms. In this work, we present SpeckleCam, a camera-based system to reconstruct high resolution 3D blood flow distribution deep inside the skin. Our approach replaces the traditional forward model using diffuse approximations with Monte-Carlo simulations-based convolutional forward model, which enables us to develop an improved deep tissue blood flow reconstruction algorithm. We show that our proposed approach can recover complex structures up to 6 mm deep inside a tissue-like scattering medium in the reflection geometry. We also conduct human experiments to demonstrate that our approach can detect reduced flow in major blood vessels during vascular occlusion. 
    more » « less
  4. Multiple scattering is a major barrier that limits the optical imaging depth in scattering media. In order to alleviate this effect, we demonstrate aberration-diverse optical coherence tomography (AD-OCT), which exploits the phase correlation between the deterministic signals from single-scattered photons to suppress the random background caused by multiple scattering and speckle. AD-OCT illuminates the sample volume with diverse aberrated point spread functions, and computationally removes these intentionally applied aberrations. After accumulating 12 astigmatism-diverse OCT volumes, we show a 10 dB enhancement in signal-to-background ratio via a coherent average of reconstructed signals from a USAF target located 7.2 scattering mean free paths below a thick scattering layer, and a 3× speckle contrast reduction from an incoherent average of reconstructed signals inside the scattering layer. This AD-OCT method, when implemented using astigmatic illumination, is a promising approach for ultra-deep volumetric optical coherence microscopy. 
    more » « less
  5. Combining laser technology with robotic precision and accuracy promises to introduce significant advances in minimally invasive surgical interventions. Lasers have already become a widespread tool in numerous surgical applications. They are proposed as a replacement for traditional tools (i.e., scalpels and electrocautery devices) to minimize surgical trauma, decrease healing times, and reduce the risk of postoperative complications. Compared to other energy sources, laser energy is wavelength‐dependent, allowing for preferential energy absorption in specific tissue types. This potentially leads to minimizing damage to healthy tissue and increasing surgical outcomes control and quality. Merging robotic control with laser techniques can help physicians achieve more accurate laser aiming and pave the way to automatic control of laser–tissue interactions in closed loop. Herein, a review of the state‐of‐the‐art robotic systems for laser surgery is presented. The goals of this paper are to present recent contributions in advanced intelligent systems for robot‐assisted laser surgery, provide readers with a better understanding of laser optics and the physics of laser–tissue interactions, discuss clinical applications of lasers in surgery, and provide guidance for future systems design. 
    more » « less