Title: In vitro characterization of solute transport in the spinal canal
This paper presents results of an experimental investigation of solute transport in a simplified model of the spinal canal. The work aims to provide increased understanding of the mechanisms responsible for drug dispersion in intrathecal drug delivery (ITDD) procedures. The model consists of an annular channel bounded externally by a rigid transparent tube of circular section, representing the dura mater, and internally by an eccentric cylindrical compliant insert, representing the spinal cord. The tube, closed at one end, is connected to a rigid acrylic reservoir, representing the cranial cavity. The system is filled with water, whose properties are almost identical to those of the cerebrospinal fluid. A programmable peristaltic pump is employed to generate oscillatory motion at frequencies that are representative of those induced by the cardiac and respiratory cycles. Laser induced fluorescence is used to characterize the dispersion of fluorescent dye along the canal and into the cranial cavity for different values of the relevant Womersley number and different eccentricities of the annular section. The present work corroborates experimentally, for the first time, the existence of a steady bulk flow, associated with the mean Lagrangian motion, which plays a key role in the transport of the solute along the spinal canal. The measurements of solute dispersion are found to be in excellent agreement with theoretical predictions obtained using a simplified transport equation derived earlier on the basis of a two-timescale asymptotic analysis. The experimental results underscore the importance of the eccentricity and its variations along the canal and identifies changes in the flow topology associated with differences in the Womersley number, with potential implications in guiding future designs of ITDD protocols.  more » « less
Award ID(s):
1853954
PAR ID:
10589283
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
American Institute of Physics
Date Published:
Journal Name:
Physics of Fluids
Volume:
35
Issue:
5
ISSN:
1070-6631
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This paper investigates flow and transport in a slender wavy-walled vertical channel subject to a prescribed oscillatory pressure difference between its ends. When the ratio of the stroke length of the pulsatile flow to the channel wavelength is small, the resulting flow velocity is known to include a slow steady-streaming component resulting from the effect of the convective acceleration. Our study considers the additional effect of gravitational forces in configurations with a non-uniform density distribution. Specific attention is given to the slowly evolving buoyancy-modulated flow emerging after the deposition of a finite amount of solute whose density is different from that of the fluid contained in the channel, a relevant problem in connection with drug dispersion in intrathecal drug delivery (ITDD) processes, involving the injection of the drug into the cerebrospinal fluid that fills the spinal canal. It is shown that when the Richardson number is of order unity, the relevant limit in ITDD applications, the resulting buoyancy-induced velocities are comparable to those of steady streaming. As a consequence, the slow time-averaged Lagrangian motion of the fluid, involving the sum of the Stokes drift and the time-averaged Eulerian velocity, is intimately coupled with the transport of the solute, resulting in a slowly evolving problem that can be treated with two-time-scale methods. The asymptotic development leads to a time-averaged, nonlinear integro-differential transport equation that describes the slow dispersion of the solute, thereby circumventing the need to describe the small concentration fluctuations associated with the fast oscillatory motion. The ideas presented here can find application in developing reduced models for future quantitative analyses of drug dispersion in the spinal canal. 
    more » « less
  2. This paper addresses the viscous flow developing about an array of equally spaced identical circular cylinders aligned with an incompressible fluid stream whose velocity oscillates periodically in time. The focus of the analysis is on harmonically oscillating flows with stroke lengths that are comparable to or smaller than the cylinder radius, such that the flow remains two-dimensional, time-periodic and symmetric with respect to the centreline. Specific consideration is given to the limit of asymptotically small stroke lengths, in which the flow is harmonic at leading order, with the first-order corrections exhibiting a steady-streaming component, which is computed here along with the accompanying Stokes drift. As in the familiar case of oscillating flow over a single cylinder, for small stroke lengths, the associated time-averaged Lagrangian velocity field, given by the sum of the steady-streaming and Stokes-drift components, displays recirculating vortices, which are quantified for different values of the two relevant controlling parameters, namely, the Womersley number and the ratio of the inter-cylinder distance to the cylinder radius. Comparisons with results of direct numerical simulations indicate that the description of the Lagrangian mean flow for infinitesimally small values of the stroke length remains reasonably accurate even when the stroke length is comparable to the cylinder radius. The numerical integrations are also used to quantify the streamwise flow rate induced by the presence of the cylinder array in cases where the periodic surrounding motion is driven by an anharmonic pressure gradient, a problem of interest in connection with the oscillating flow of cerebrospinal fluid around the nerve roots located along the spinal canal. 
    more » « less
  3. This paper addresses peristaltic flow induced in a non-axisymmetric annular tube by a periodic small-amplitude wave of arbitrary shape propagating axially along its inner surface, assumed to be a circular cylinder. The study is motivated by recent in vivo experimental observations pertaining to the flow of cerebrospinal fluid along the perivascular spaces of cerebral arteries. The analysis employs the lubrication approximation, describing low-Reynolds-number peristaltic flow in the long-wavelength approximation. Closed-form analytic expressions are derived for the average pumping rate in infinitely long tubes and also in tubes of finite length. Consideration is also given to the transverse motion arising in non-axisymmetric tubes. For small-amplitude waves, the solution is reduced to the integration of a parameter-free Stokes-flow problem, which is solved for relevant cross-sectional shapes, with closed-form analytical results derived for thin canals. 
    more » « less
  4. We develop a theory of fluid--structure interaction (FSI) between an oscillatory Newtonian fluid flow and a compliant conduit. We consider the canonical geometries of a 2D channel with a deformable top wall and an axisymmetric deformable tube. Focusing on the hydrodynamics, we employ a linear relationship between wall displacement and hydrodynamic pressure, which has been shown to be suitable for a leading-order-in-slenderness theory. The slenderness assumption also allows the use of lubrication theory, and the flow rate is related to the pressure gradient (and the tube/wall deformation) via the classical solutions for oscillatory flow in a channel and in a tube (attributed to Womersley). Then, by two-way coupling the oscillatory flow and the wall deformation via the continuity equation, a one-dimensional nonlinear partial differential equation (PDE) governing the instantaneous pressure distribution along the conduit is obtained, without \textit{a priori} assumptions on the magnitude of the oscillation frequency (\textit{i.e.}, at arbitrary Womersley number). We find that the cycle-averaged pressure (for harmonic pressure-controlled conditions) deviates from the expected steady pressure distribution, suggesting the presence of a streaming flow. An analytical perturbative solution for a weakly deformable conduit is obtained to rationalize how FSI induces such streaming. In the case of a compliant tube, the results obtained from the proposed reduced-order PDE and its perturbative solutions are validated against three-dimensional, two-way-coupled direct numerical simulations. We find good agreement between theory and simulations for a range of dimensionless parameters characterizing the oscillatory flow and the FSI, demonstrating the validity of the proposed theory of oscillatory flows in compliant conduits at arbitrary Womersley number. 
    more » « less
  5. null (Ed.)
    The blood–brain barrier (BBB) is a major obstacle for drug delivery to the central nervous system (CNS) such that most therapeutics lack efficacy against brain tumors or neurological disorders due to their inability to cross the BBB. Therefore, developing new drug delivery platforms to facilitate drug transport to the CNS and understanding their mechanism of transport are crucial for the efficacy of therapeutics. Here, we report (i) carbon dots prepared from glucose and conjugated to fluorescein (GluCD-F) cross the BBB in zebrafish and rats without the need of an additional targeting ligand and (ii) uptake mechanism of GluCDs is glucose transporter-dependent in budding yeast. Glucose transporter-negative strain of yeast showed undetectable GluCD accumulation unlike the glucose transporter-positive yeast, suggesting glucose-transporter-dependent GluCD uptake. We tested GluCDs' ability to cross the BBB using both zebrafish and rat models. Following the injection to the heart, wild-type zebrafish showed GluCD-F accumulation in the central canal consistent with the transport of GluCD-F across the BBB. In rats, following intravenous administration, GluCD-F was observed in the CNS. GluCD-F was localized in the gray matter ( e.g. ventral horn, dorsal horn, and middle grey) of the cervical spinal cord consistent with neuronal accumulation. Therefore, neuron targeting GluCDs hold tremendous potential as a drug delivery platform in neurodegenerative disease, traumatic injury, and malignancies of the CNS. 
    more » « less