skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Lensfree time-gated photoluminescent imaging
Fluorescence and, more generally, photoluminescence enable high contrast imaging of targeted regions of interest through the use of photoluminescent probes with high specificity for different targets. Fluorescence can be used for rare cell imaging; however, this often requires a high space-bandwidth product: simultaneous high resolution and large field of view. With bulky traditional microscopes, high space-bandwidth product images require time-consuming mechanical scanning and stitching. Lensfree imaging can compactly and cost-effectively achieve a high space-bandwidth product in a single image through computational reconstruction of images from diffraction patterns recorded over the full field of view of standard image sensors. Many methods of lensfree photoluminescent imaging exist, where the excitation light is filtered before the image sensor, often by placing spectral filters between the sample and sensor. However, the sample-to-sensor distance is one of the limiting factors on resolution in lensfree systems and so more competitive performance can be obtained if this distance is reduced. Here, we show a time-gated lensfree photoluminescent imaging system that can achieve a resolution of 8.77 µm. We use europium chelate fluorophores because of their long lifetime (642 µs) and trigger camera exposure ∼50 µs after excitation. Because the excitation light is filtered temporally, there is no need for physical filters, enabling reduced sample-to-sensor distances and higher resolutions.  more » « less
Award ID(s):
2114275
PAR ID:
10594408
Author(s) / Creator(s):
;
Publisher / Repository:
American Institute of Physics
Date Published:
Journal Name:
APL Photonics
Volume:
8
Issue:
6
ISSN:
2378-0967
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Fluorescence microscopes are indispensable to biology and neuroscience. The need for recording in freely behaving animals has further driven the development in miniaturized microscopes (miniscopes). However, conventional microscopes/miniscopes are inherently constrained by their limited space-bandwidth product, shallow depth of field (DOF), and inability to resolve three-dimensional (3D) distributed emitters. Here, we present a Computational Miniature Mesoscope (CM 2 ) that overcomes these bottlenecks and enables single-shot 3D imaging across an 8 mm by 7 mm field of view and 2.5-mm DOF, achieving 7-μm lateral resolution and better than 200-μm axial resolution. The CM 2 features a compact lightweight design that integrates a microlens array for imaging and a light-emitting diode array for excitation. Its expanded imaging capability is enabled by computational imaging that augments the optics by algorithms. We experimentally validate the mesoscopic imaging capability on 3D fluorescent samples. We further quantify the effects of scattering and background fluorescence on phantom experiments. 
    more » « less
  2. In the past two decades, spectral imaging technologies have expanded the capacity of fluorescence microscopy for accurate detection of multiple labels, separation of labels from cellular and tissue autofluorescence, and analysis of autofluorescence signatures. These technologies have been implemented using a range of optical techniques, such as tunable filters, diffraction gratings, prisms, interferometry, and custom Bayer filters. Each of these techniques has associated strengths and weaknesses with regard to spectral resolution, spatial resolution, temporal resolution, and signal-to-noise characteristics. We have previously shown that spectral scanning of the fluorescence excitation spectrum can provide greatly increased signal strength compared to traditional emission-scanning approaches. Here, we present results from utilizing a Hyperspectral Imaging Fluorescence Excitation Scanning (HIFEX) microscope system for live cell imaging. Live cell signaling studies were performed using HEK 293 and rat pulmonary microvascular endothelial cells (PMVECs), transfected with either a cAMP FRET reporter or a Ca2+ reporter. Cells were further labeled to visualize subcellular structures (nuclei, membrane, mitochondria, etc.). Spectral images were acquired using a custom inverted microscope (TE2000, Nikon Instruments) equipped with a 300W Xe arc lamp and tunable excitation filter (VF- 5, Sutter Instrument Co., equipped with VersaChrome filters, Semrock), and run through MicroManager. Timelapse spectral images were acquired from 350-550 nm, in 5 nm increments. Spectral image data were linearly unmixed using custom MATLAB scripts. Results indicate that the HIFEX microscope system can acquire live cell image data at acquisition speeds of 8 ms/wavelength band with minimal photobleaching, sufficient for studying moderate speed cAMP and Ca2+ events. 
    more » « less
  3. Image resolution and field of view in far-field optical microscopy are often inversely proportional to one another due to digital sampling limitations imposed by the magnification of the system and the pixel size of the sensor. We present a method including a spatial shifting mechanism and a reconstruction algorithm that bypasses this trade-off by shifting the sample to be imaged by subpixel increments, before registering the images via phase correlation and combining the resulting registered images using the shift-and-add approach. Importantly, this method requires no specific optical components that are uncommon to commercially available or custom-built microscope systems. The findings of the presented study demonstrate an improvement to spatial resolution of ∼42% while maintaining the system’s field of view (FOV), leading to a more than twofold improvement to the system’s space–bandwidth product (SBP). 
    more » « less
  4. Abstract We present a feature-selective segmentation and merging technique to achieve spatially resolved surface profiles of the parts by 3D stereoscopy and strobo-stereoscopy. A pair of vision cameras capture images of the parts at different angles, and 3D stereoscopic images can be reconstructed. Conventional filtering processes of the 3D images involve data loss and lower the spatial resolution of the image. In this study, the 3D reconstructed image was spatially resolved by automatically recognizing and segmenting the features on the raw images, locally and adaptively applying super-resolution algorithm to the segmented images based on the classified features, and then merging those filtered segments. Here, the features are transformed into masks that selectively separate the features and background images for segmentation. The experimental results were compared with those of conventional filtering methods by using Gaussian filters and bandpass filters in terms of spatial frequency and profile accuracy. As a result, the selective feature segmentation technique was capable of spatially resolved 3D stereoscopic imaging while preserving imaging features. 
    more » « less
  5. Background Structured illumination microscopy (SIM) is a family of methods in optical fluorescence microscopy that can achieve both optical sectioning and super-resolution effects. SIM is a valuable method for high-resolution imaging of fixed cells or tissues labeled with conventional fluorophores, as well as for imaging the dynamics of live cells expressing fluorescent protein constructs. In SIM, one acquires a set of images with shifting illumination patterns. This set of images is subsequently treated with image analysis algorithms to produce an image with reduced out-of-focus light (optical sectioning) and/or with improved resolution (super-resolution). Findings Five complete, freely available SIM datasets are presented including raw and analyzed data. We report methods for image acquisition and analysis using open-source software along with examples of the resulting images when processed with different methods. We processed the data using established optical sectioning SIM and super-resolution SIM methods and with newer Bayesian restoration approaches that we are developing. Conclusions Various methods for SIM data acquisition and processing are actively being developed, but complete raw data from SIM experiments are not typically published. Publically available, high-quality raw data with examples of processed results will aid researchers when developing new methods in SIM. Biologists will also find interest in the high-resolution images of animal tissues and cells we acquired. All of the data were processed with SIMToolbox, an open-source and freely available software solution for SIM. 
    more » « less