Title: Performance of a large area photon detector for rare event search applications
We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature Tc=41.5 mK to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated 55Fe x-ray source incident on the center of the detector. The noise equivalent power is measured to be 1×10−17 W/Hz in a bandwidth of 2.7 kHz. The baseline energy resolution is measured to be σE=3.86±0.04 (stat.)−0.00+0.19 (syst.) eV. The detector also has an expected timing resolution of σt=2.3 μs for 5 σE events.  more » « less
Award ID(s):
1809480
PAR ID:
10594674
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
American Institute of Physics
Date Published:
Journal Name:
Applied Physics Letters
Volume:
118
Issue:
2
ISSN:
0003-6951
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Entangled two-photon absorption (ETPA) is known to create photoinduced transitions with extremely low light intensity, reducing the risk of phototoxicity compared to classical two-photon absorption. Previous works have predicted the ETPA cross-section, σe, to vary inversely with the product of entanglement time (Te) and entanglement area (Ae), i.e., σe ∼ 1/AeTe. The decreasing σe with increasing Te has limited ETPA to fs-scale Te, while ETPA applications for ps-scale spectroscopy have been unexplored. However, we show that spectral−spatial coupling, which reduces Ae as the SPDC bandwidth (σf ) decreases, plays a significant role in determining σe when Te > ∼100 fs. We experimentally measured σe for zinc tetraphenylporphyrin at several σf values. For type-I ETPA, σe increases as σf decreases down to 0.1 ps−1 . For type-II SPDC, σe is constant for a wide range of σf . With a theoretical analysis of the data, the maximum type-I σe would occur at σf = 0.1 ps−1 (Te = 10 ps). At this maximum, σe is 1 order of magnitude larger than fs-scale σe and 3 orders of magnitude larger than previous predictions of ps-scale σe. By utilizing this spectral−spatial coupling, narrowband type-I ETPA provides a new opportunity to increase the efficiency of measuring nonlinear optical signals and to control photochemical reactions requiring ps temporal precision. 
    more » « less
  2. ABSTRACT Early-type galaxies – slow and fast rotating ellipticals (E-SRs and E-FRs) and S0s/lenticulars – define a Fundamental Plane (FP) in the space of half-light radius Re, enclosed surface brightness Ie, and velocity dispersion σe. Since Ie and σe are distance-independent measurements, the thickness of the FP is often expressed in terms of the accuracy with which Ie and σe can be used to estimate sizes Re. We show that: (1) The thickness of the FP depends strongly on morphology. If the sample only includes E-SRs, then the observed scatter in Re is $$\sim 16{{\ \rm per\ cent}}$$, of which only $$\sim 9{{\ \rm per\ cent}}$$ is intrinsic. Removing galaxies with M* < 1011 M⊙ further reduces the observed scatter to $$\sim 13{{\ \rm per\ cent}}$$ ($$\sim 4{{\ \rm per\ cent}}$$ intrinsic). The observed scatter increases to $$\sim 25{{\ \rm per\ cent}}$$ usually quoted in the literature if E-FRs and S0s are added. If the FP is defined using the eigenvectors of the covariance matrix of the observables, then the E-SRs again define an exceptionally thin FP, with intrinsic scatter of only 5 per cent orthogonal to the plane. (2) The structure within the FP is most easily understood as arising from the fact that Ie and σe are nearly independent, whereas the Re−Ie and Re−σe correlations are nearly equal and opposite. (3) If the coefficients of the FP differ from those associated with the virial theorem the plane is said to be ‘tilted’. If we multiply Ie by the global stellar mass-to-light ratio M*/L and we account for non-homology across the population by using Sérsic photometry, then the resulting stellar mass FP is less tilted. Accounting self-consistently for M*/L gradients will change the tilt. The tilt we currently see suggests that the efficiency of turning baryons into stars increases and/or the dark matter fraction decreases as stellar surface brightness increases. 
    more » « less
  3. FASER, or the Forward Search Experiment, is a new experiment at CERN designed to complement the LHC’s ongoing physics program, extending its discovery potential to light and weakly interacting particles that may be produced copiously at the LHC in the far-forward region. New particles targeted by FASER, such as long-lived dark photons or axion-like particles, are characterised by a signature with two oppositely charged tracks or two photons in the multi-TeV range that emanate from a common vertex inside the detector. The full detector was successfully installed in March 2021 in an LHC side tunnel 480 m downstream from the interaction point in the ATLAS detector. FASER is planned to be operational for LHC Run 3. The experiment is composed of a silicon-strip tracking-based spectrometer using three dipole magnets with a 20 cm aperture, supplemented by four scintillator stations and an electromagnetic calorimeter. The FASER electromagnetic calorimeter is constructed from four spare LHCb calorimeter modules. The modules are of the Shashlik type with interleaved scintillator and lead plates that result in 25 radiation lengths and 1% energy resolution for TeV electromagnetic showers. In 2021, a test beam campaign was carried out using one of the CERN SPS beam lines to set up the calibration of the FASER calorimeter system in preparation for physics data taking. The relative calorimeter response to electrons with energies between 10 and 300 GeV, as well as high energy muons and pions, has been measured under various high voltage settings and beam positions. The measured calorimeter resolution, energy calibration, and particle identification capabilities are presented. 
    more » « less
  4. Abstract The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, U.S.A. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of 7 × 6 × 7.2 m 3 . The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components. 
    more » « less
  5. Abstract We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV. 
    more » « less