skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Do Immobilization Methods Affect Force Spectroscopy Measurements of Single Bacteria?
Increasing antibiotic resistance in bacteria is a critical issue that often leads to infections or other morbidities. Mechanical properties of the bacterial cell wall, such as thickness or elastic modulus, may contribute to the ability of a bacterial cell to resist antibiotics. Techniques like atomic force microscopy (AFM) are used to quantify bacterial cell mechanical properties and image cell structures at nanoscale resolutions. An additional benefit of AFM is the ability to probe samples submerged in liquids, meaning that live bacteria can be imaged or evaluated in environments that more accurately simulate in vivo conditions as compared to other methods like electron microscopy. However, because AFM measurements are highly sensitive to small perturbations in the deflection of the tip of a sensor probe brought into contact with the specimen, immobilization of bacteria prior to measurement is essential for accurate measurements. Traditional chemical fixatives crosslink the molecules within the bacterial cell wall, which prevent the bacteria from locomotion. While effective for imaging, chemical crosslinkers are known to affect the measured stiffness of eukaryotic cells and also may affect the measured stiffness of the bacterial cell wall. Alternative immobilization methods include Cell-Tak™, an adhesive derived from marine mussels that does not interact with the bacterial wall and filters with known pore sizes which entrap bacteria. Previous studies have examined the effect of these immobilization methods on successful imaging of bacteria but have not addressed differences in measured modulus. This study compares the effects of immobilization methods including chemical fixatives, mechanical entrapment in filters, and Cell-Tak™ on the stiffness of the bacterial cell wall as measured by force spectroscopy.  more » « less
Award ID(s):
2045853
PAR ID:
10598434
Author(s) / Creator(s):
;
Publisher / Repository:
Springer International Publishing
Date Published:
Page Range / eLocation ID:
17 to 20
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Nuclear mechanics is emerging as a key component of stem cell function and differentiation. While changes in nuclear structure can be visually imaged with confocal microscopy, mechanical characterization of the nucleus and its sub-cellular components require specialized testing equipment. A computational model permitting cell-specific mechanical information directly from confocal and atomic force microscopy of cell nuclei would be of great value. Here, we developed a computational framework for generating finite element models of isolated cell nuclei from multiple confocal microscopy scans and simple atomic force microscopy (AFM) tests. Confocal imaging stacks of isolated mesenchymal stem cells were converted into finite element models and siRNA-mediated Lamin A/C depletion isolated chromatin and Lamin A/C structures. Using AFM-measured experimental stiffness values, a set of conversion factors were determined for both chromatin and Lamin A/C to map the voxel intensity of the original images to the element stiffness, allowing the prediction of nuclear stiffness in an additional set of other nuclei. The developed computational framework will identify the contribution of a multitude of sub-nuclear structures and predict global nuclear stiffness of multiple nuclei based on simple nuclear isolation protocols, confocal images and AFM tests. 
    more » « less
  2. Guichard, P.; Hamel, V. (Ed.)
    This chapter describes two mechanical expansion microscopy methods with accompanying step-by-step protocols. The first method, mechanically resolved expansion microscopy, uses non-uniform expansion of partially digested samples to provide the imaging contrast that resolves local mechanical properties. Examining bacterial cell wall with this method, we are able to distinguish bacterial species in mixed populations based on their distinct cell wall rigidity and detect cell wall damage caused by various physiological and chemical perturbations. The second method is mechanically locked expansion microscopy, in which we use a mechanically stable gel network to prevent the original polyacrylate network from shrinking in ionic buffers. This method allows us to use anti-photobleaching buffers in expansion microscopy, enabling detection of novel ultra-structures under the optical diffraction limit through super-resolution single molecule localization microscopy on bacterial cells and whole-mount immunofluorescence imaging in thick animal tissues. We also discuss potential applications and assess future directions. 
    more » « less
  3. Atomic force microscopy (AFM) provides a platform for high-resolution topographical imaging and the mechanical characterization of a wide range of samples, including live cells, proteins, and other biomolecules. AFM is also instrumental for measuring interaction forces and binding kinetics for protein–protein or receptor–ligand interactions on live cells at a single-molecule level. However, performing force measurements and high-resolution imaging with AFM and data analytics are time-consuming and require special skill sets and continuous human supervision. Recently, researchers have explored the applications of artificial intelligence (AI) and deep learning (DL) in the bioimaging field. However, the applications of AI to AFM operations for live-cell characterization are little-known. In this work, we implemented a DL framework to perform automatic sample selection based on the cell shape for AFM probe navigation during AFM biomechanical mapping. We also established a closed-loop scanner trajectory control for measuring multiple cell samples at high speed for automated navigation. With this, we achieved a 60× speed-up in AFM navigation and reduced the time involved in searching for the particular cell shape in a large sample. Our innovation directly applies to many bio-AFM applications with AI-guided intelligent automation through image data analysis together with smart navigation. 
    more » « less
  4. Jabbari, Esmaiel (Ed.)
    This study presents novel biocompatible Polydimethylsiloxane (PDMS)-based micromechanical tweezers (μTweezers) capable of the stiffness characterization and manipulation of hydrogel-based organoids. The system showed great potential for complementing established mechanical characterization methods such as Atomic Force Microscopy (AFM), parallel plate compression (PPC), and nanoindentation, while significantly reducing the volume of valuable hydrogels used for testing. We achieved a volume reduction of ~0.22 μl/sample using the μTweezers vs. ~157 μl/sample using the PPC, while targeting high-throughput measurement of widely adopted micro-mesoscale (a few hundred μm-1500 μm) 3D cell cultures. The μTweezers applied and measured nano-millinewton forces through cantilever’ deflection with high linearity and tunability for different applications; the assembly is compatible with typical inverted optical microscopes and fit on standard tissue culture Petri dishes, allowing mechanical compression characterization of arrayed 3D hydrogel-based organoids in a high throughput manner. The average achievable output per group was 40 tests per hour, where 20 organoids and 20 reference images in one 35 mm petri dish were tested, illustrating efficient productivity to match the increasing demand on 3D organoids’ applications. The changes in stiffness of collagen I hydrogel organoids in four conditions were measured, with ovarian cancer cells (SKOV3) or without (control). The Young’s modulus of the control group (Control—day 0, E = 407± 146, n = 4) measured by PPC was used as a reference modulus, where the relative elastic compressive modulus of the other groups based on the stiffness measurements was also calculated (control-day 0, E = 407 Pa), (SKOV3-day 0, E = 318 Pa), (control-day 5, E = 528 Pa), and (SKOV3-day 5, E = 376 Pa). The SKOV3-embedded hydrogel-based organoids had more shrinkage and lowered moduli on day 0 and day 5 than controls, consistently, while SKOV3 embedded organoids increased in stiffness in a similar trend to the collagen I control from day 0 to day 5. The proposed method can contribute to the biomedical, biochemical, and regenerative engineering fields, where bulk mechanical characterization is of interest. The μTweezers will also provide attractive design and application concepts to soft membrane-micro 3D robotics, sensors, and actuators. 
    more » « less
  5. This Letter reports that the atomic corrugation of the surface can affect nanoscale interfacial adhesion and friction differently. Both atomic force microscopy (AFM) and molecular dynamics (MD) simulations showed that the adhesion force needed to separate a silica tip from a graphene step edge increases as the side wall of the tip approaches the step edge when the tip is on the lower terrace and decreases as the tip ascends or descends the step edge. However, the friction force measured with the same AFM tip moving across the step edge does not positively correlate with the measured adhesion, which implies that the conventional contact mechanics approach of correlating interfacial adhesion and friction could be invalid for surfaces with atomic-scale features. The chemical and physical origins for the observed discrepancy between adhesion and friction at the atomic step edge are discussed. 
    more » « less