skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Mechanically Induced Deformation of Nuclei in the Tricuspid Valve Interstitial Cells: Experimental Measurements and Multi-scale Computational Simulation
Abstract We examined the mechanical deformation of valve interstitial cells (VICs) in the anterior leaflet of the tricuspid valve and explored the relationship between the extracellular matrix (ECM) structure and cellular mechanics. Fresh porcine hearts were used to prepare specimens, subjected to biaxial tensile testing, and imaged using confocal microscopy with VIC nuclei staining. A multi-scale computational framework was developed to analyze cellular deformation and orientation within the ECM, using nuclear aspect ratio (NAR) as a metric. Experimental results showed that NAR values increased with mechanical loading, from 2.57±0.72 in a traction-free state to 3.4±1.29 at 130 kPa. Model predictions aligned with experimental findings. They also highlighted the significant impact of ECM fiber orientation on VIC nuclei deformation. These results indicate that mechanical forces profoundly influence cellular morphology and, potentially, their function. Further development of models is necessary to understand the complex interplay between the mechanical environment and cellular responses, crucial for identifying how mechanical forces affect tricuspid valve function and malfunction.  more » « less
Award ID(s):
2049088
PAR ID:
10629028
Author(s) / Creator(s):
; ; ; ; ; ; ;
Publisher / Repository:
ASME
Date Published:
Journal Name:
ASME Open Journal of Engineering
Volume:
3
ISSN:
2770-3495
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Jiang, Yi (Ed.)
    Elastin is present in the extracellular matrix (ECM) of connective tissues, and its mechanical properties are well documented. In Marfan syndrome, however, the inability to properly code for the protein fibrillin-1 prematurely leads to the degradation and loss of elastin fiber integrity in the ECM. In this study, the role of elastin in the ECM of the anterior leaflet of the tricuspid valve was investigated by examining the biomechanical behavior of porcine leaflets before and after the application of the enzyme elastase. Five loading protocols were applied to the leaflet specimens in two groups (elastase-treated and control samples). The mechanical response following elastase application yielded a significantly stiffer material in both the radial and circumferential directions. At a physiological level of stress (85 kPa), the elastase group had an average strain of 26.21% and 6.32% in the radial and circumferential directions, respectively, at baseline prior to elastase application. Following elastase treatment, the average strain was 5.28% and 0.97% in the radial and circumferential directions, respectively. No statistically significant change was found in the control group following sham treatment with phosphate-buffered saline (PBS). Two-photon microscopy images confirmed that after the removal of elastin, the collagen fibers displayed a loss of undulation. With a significant reduction in radial compliance, the ability to withstand physiological loads may be compromised. As such, an extracellular matrix that is structurally deficient in elastin may hinder normal tricuspid valve function. 
    more » « less
  2. Mechanical characterization of the ex vivo tricuspid valve (TV) continues to provide key insights into native valve function and the development of valvular diseases. However, experimental methods to characterize TV biomechanical behavior ex vivo often fail to account for potential changes in the tissue’s mechanical responses that may occur during experiment preparation. Therefore, we assessed the mechanical responses of the anterior tricuspid leaflet (ATL) via biaxial mechanical testing over the course of 5 h to validate the accuracy of our fresh tissue experiments. We hypothesized that ATL mechanical responses would remain consistent for the proposed time scale. We found that ATL stiffness, represented by the upper tangent modulus (UTM), did not significantly change in either the radial or circumferential directions for the 5-h test period. Similarly, no significant change was observed in radial or circumferential strains corresponding to an estimated mean systolic stress value of 85 kPa. Overall mean UTM (±standard error of the mean (SEM)) showed that ATL samples were significantly stiffer in the circumferential direction (11.3 ± 0.98 MPa) compared to the radial direction (2.29 ± 0.20 MPa) across all time points. Thus, our results indicate that the outcomes of ex vivo tricuspid valve studies requiring sample preparation up to 5 h remain reliable. 
    more » « less
  3. Clinically serious congenital heart valve defects arise from improper growth and remodeling of endocardial cushions into leaflets. Genetic mutations have been extensively studied but explain less than 20% of cases. Mechanical forces generated by beating hearts drive valve development, but how these forces collectively determine valve growth and remodeling remains incompletely understood. Here, we decouple the influence of those forces on valve size and shape, and study the role of YAP pathway in determining the size and shape. The low oscillatory shear stress promotes YAP nuclear translocation in valvular endothelial cells (VEC), while the high unidirectional shear stress restricts YAP in cytoplasm. The hydrostatic compressive stress activated YAP in valvular interstitial cells (VIC), whereas the tensile stress deactivated YAP. YAP activation by small molecules promoted VIC proliferation and increased valve size. Whereas YAP inhibition enhanced the expression of cell-cell adhesions in VEC and affected valve shape. Finally, left atrial ligation was performed in chick embryonic hearts to manipulate the shear and hydrostatic stress in vivo. The restricted flow in the left ventricle induced a globular and hypoplastic left atrioventricular (AV) valves with an inhibited YAP expression. By contrast, the right AV valves with sustained YAP expression grew and elongated normally. This study establishes a simple yet elegant mechanobiological system by which transduction of local stresses regulates valve growth and remodeling. This system guides leaflets to grow into proper sizes and shapes with the ventricular development, without the need of a genetically prescribed timing mechanism. 
    more » « less
  4. Abstract Understanding the large deformation behavior of materials under external forces is crucial for reliable engineering applications. The mechanical properties of materials depend on their underlying microstructures, which change over time during deformation. Experimental observation of these processes is time-consuming and influenced by various conditions. Therefore, we developed , a physics-based simulation tool to replicate the deformation process of cubic microstructures. can predict the evolution of texture, represented by the orientation distribution function (ODF), over time under various loads and strain rates. This software package can be run on both Windows and Linux operating systems. Unlike conventional crystal plasticity finite element software, offers a distinct advantage by rapidly generating deformed textures, as it bypasses incorporating grain morphology. Furthermore, comparisons with existing experimental and computational studies on texture evolution have demonstrated that this software seamlessly replicates real-world material processing conditions through a simple modification of a single input matrix. 
    more » « less
  5. The heterogeneous micromechanical properties of biological tissues have profound implications across diverse medical and engineering domains. However, identifying full‐field heterogeneous elastic properties of soft materials using traditional engineering approaches is fundamentally challenging due to difficulties in estimating local stress fields. Recently, there has been a growing interest in data‐driven models for learning full‐field mechanical responses, such as displacement and strain, from experimental or synthetic data. However, research studies on inferring full‐field elastic properties of materials, a more challenging problem, are scarce, particularly for large deformation, hyperelastic materials. Here, a physics‐informed machine learning approach is proposed to identify the elasticity map in nonlinear, large deformation hyperelastic materials. This study reports the prediction accuracies and computational efficiency of physics‐informed neural networks (PINNs) in inferring the heterogeneous elasticity maps across materials with structural complexity that closely resemble real tissue microstructure, such as brain, tricuspid valve, and breast cancer tissues. Further, the improved architecture is applied to three hyperelastic constitutive models: Neo‐Hookean, Mooney Rivlin, and Gent. The improved network architecture consistently produces accurate estimations of heterogeneous elasticity maps, even when there is up to 10% noise present in the training data. 
    more » « less