Several ways to address the looming ecological disaster that is the Salton Sea have been proposed — including water importation. Here we considered two options: importing ocean water from the Sea of Cortés and leasing water from agricultural users in the Imperial Valley. We estimated the monetary costs for importing Sea of Cortés water to the Salton Sea and compared that with the costs of transferring water from agricultural users to the Salton Sea. We found that leasing water from agriculture would be substantially cheaper than ocean water imports. Additionally, all the infrastructure for leasing water from growers exists, which means water transfers could begin immediately. That is important given the present and increasing environmental and human health damages that are occurring at the Salton Sea.
more »
« less
Stream water chemistry data for Martinelli basin, 1984 - ongoing.
This is a summary of major ion concentrations for water samples from the outlet stream of the Martinelli Basin. Water usually flows seasonally from May to September.
more »
« less
- Award ID(s):
- 2224439
- PAR ID:
- 10632811
- Publisher / Repository:
- Environmental Data Initiative
- Date Published:
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract In the United States, thermal power plant electrical generators (EGs) are large water diverters and consumptive users who need water for cooling. Retrofitting existing cooling systems to dry cooling and building new facilities with dry cooling can save water and reduce EG's vulnerability to drought. However, this can be an expensive source of water. We estimate that the cost of water saved by retrofitting cooling in existing EGs ranges from $0.04/m3to $18/m3depending on facility characteristics. Also water savings from building new EGs with dry cooling ranges in cost per unit water from $1.29/m3to $2.24/m3. We compare costs with that for water development projects identified in the Texas State Water Plan. We find the water cost from converting to dry cooling is lower than many of the water development possibilities. We then estimate the impact of climate change on the cost of water saved, finding climate change can increase EG water use by up to 9.3% and lower the costs of water saved. Generally, it appears that water planners might consider cooling alterations as a cost competitive water development alternative whose cost would be further decreased by climate change.more » « less
-
Abstract Water consumed by power plants is transferred virtually from producers to consumers on the electric grid. This network of virtual transfers varies spatially and temporally on a sub-annual scale. In this study, we focused on cooling water consumed by thermoelectric power plants and water evaporated from hydropower reservoirs. We analyzed blue and grey virtual water flows between balancing authorities in the United States electric grid from 2016 to 2021. Transfers were calculated using thermoelectric water consumption volumes reported in Form EIA-923, power plant data from Form EIA-860, water consumption factors from literature, and electricity transfer data from Form EIA-930. The results indicate that virtual water transfers follow seasonal trends. Virtual blue water transfers are dominated by evaporation from hydropower reservoirs in high evaporation regions and peak around November. Virtual grey watertransfers reach a maximum peak during the summer months and a smaller peak during the winter. Notable virtual blue water transfers occur between Arizona and California as well as surrounding regions in the Southwest. Virtual grey water transfers are greatest in the Eastern United States where older, once-through cooling systems are still in operation. Understanding the spatial and temporal transfer of water resources has important policy, water management, and equity implications for understanding burden shifts between regions.more » « less
-
Extensive building closures due to the unprecedented COVID-19 pandemic resulted in long-term water stagnation within the plumbing of large buildings. This study examined water chemical quality deterioration in ten large buildings after prolonged stagnation caused by the closure of a university campus in response to the COVID-19 pandemic. Volume-based and constant-duration flushing protocols were implemented to replace stagnant water with fresh drinking water. The effectiveness of the developed water flushing protocols was examined by monitoring the disinfectant residuals, heavy metal concentrations and temperature for water samples collected from the buildings' point of entry (POE) and select water fixtures. More than 14 m 3 of water were flushed in all ten large buildings. The results demonstrated a significantly greater average total chlorine residual concentration in POE water samples collected after flushing (1.1 mg L −1 ) compared to the stagnant condition (0.6 mg L −1 ). For water samples collected from fixtures during the extended stagnation, chlorine was absent in 71% of samples from academic buildings and 69% of samples from athletic buildings. The effectiveness of flushing practices is underscored by increasing the median total chlorine concentration from <0.1 to 1.0 mg L −1 in academic buildings and from <0.1 to 0.75 mg L −1 in athletic buildings. Furthermore, the concentrations of Pb, Zn, and Cu had decreased following the water flushing, but the concentration of Fe had increased in some buildings. This study could be beneficial to prepare for prolonged water stagnation events including but not limited to pandemics.more » « less
-
Rock glaciers are common geomorphic features in alpine landscapes and comprise a potentially significant but poorly quantified water resource. This project focused on three complementary questions germane to rock glacier hydrology: 1) Does the composition of rock glacier meltwater vary from year to year? 2) How dependent is the composition of rock glacier meltwater on lithology? And 3) How does the presence of rock glaciers in a catchment change stream water chemistry? To address these questions, we deployed automated samplers to collect water from late June through mid-October 2022 in two rock-glacierized mountain ranges in Utah, United States characterized by different lithologies. In the Uinta Mountains of northern Utah, where bedrock is predominantly quartzite, water was collected at springs discharging from two rock glaciers previously shown to release water in late summer sourced from internal ice. In the La Sal Mountains of southeastern Utah, where trachyte bedrock is widespread, water was collected at a rock glacier spring, along the main stream in a watershed containing multiple rock glaciers, and from a stream in a watershed where rock glaciers are absent. Precipitation was also collected, and data loggers for water temperature and electric conductivity were deployed. Water samples were analyzed for stable isotopes with cavity ring-down spectroscopy and hydrochemistry with ICP-MS. Our data show that water discharging from rock glaciers in the Uinta Mountains exhibits a shift from a snowmelt source to an internal ice source over the course of the melt season that is consistent from year to year. We also found that the chemistry of rock glacier water in the two study areas is notably different in ways that can be linked back to their contrasting bedrock types. Finally, in the La Sal Mountains, the properties of water along the main stream in a rock-glacierized basin resemble the properties of water discharging from rock glaciers, and strongly contrast with the water in a catchment lacking rock glaciers. Collectively these results underscore the role of rock glaciers as an agent influencing the hydrochemistry of water in high-elevation stream systems.more » « less
An official website of the United States government
