Title: Unobtrusive Swallow Monitoring Enabled by Conformal IONOGEL Biopotential Electrodes and Machine Learning
Abstract Dysphagia or difficulty swallowing is caused by the failure of neurological pathways to properly activate swallowing muscles. Current electromyography (EMG) systems for dysphagia monitoring are bulky and rigid, limiting their potential for long‐term and unobtrusive use. To address this, a machine learning‐assisted wearable EMG system is presented, utilizing self‐adhesive, skin‐conformal, semi‐transparent, and robust ionic gel electrodes. The presented electrodes possess good conductivity, superior skin contact, and good transmittance, ensuring high‐fidelity EMG sensing without impeding daily activities. Moreover, the optimized material and structural designs ensure wearing comfort and conformable skin‐electrode contact, allowing for long‐term monitoring with high accuracy. Machine learning and mel‐frequency cepstral coefficient techniques are employed to classify swallowing events based on food types and volumes. Through an analysis of electrode placement on the chin and neck, the proposed system is able to effectively distinguish between different food types and water volumes using a small number of channels, making it suitable for continuous dysphagia monitoring. This work represents an advancement in machine learning assisted EMG systems for the classification and regression of swallowing events, paving the way for more efficient, unobtrusive, and long‐term dysphagia monitoring systems.  more » « less
Award ID(s):
2335863
PAR ID:
10641124
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Materials Technologies
Volume:
10
Issue:
16
ISSN:
2365-709X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Successful rehabilitation of oropharyngeal swallowing disorders (i.e., dysphagia) requires frequent performance of head/neck exercises that primarily rely on expensive biofeedback devices, often only available in large medical centers. This directly affects treatment compliance and outcomes, and highlights the need to develop a portable and inexpensive remote monitoring system for the telerehabilitation of dysphagia. Here, we present the development and preliminarily validation of a skin-mountable sensor patch that can fit on the curvature of the submental (under the chin) area noninvasively and provide simultaneous remote monitoring of muscle activity and laryngeal movement during swallowing tasks and maneuvers. This sensor patch incorporates an optimal design that allows for the accurate recording of submental muscle activity during swallowing and is characterized by ease of use, accessibility, reusability, and cost-effectiveness. Preliminary studies on a patient with Parkinson’s disease and dysphagia, and on a healthy control participant demonstrate the feasibility and effectiveness of this system. 
    more » « less
  2. null (Ed.)
    High-resolution cervical auscultation (HRCA) is an evolving clinical method for noninvasive screening of dysphagia that relies on data science, machine learning, and wearable sensors to investigate the characteristics of disordered swallowing function in people with dysphagia. HRCA has shown promising results in categorizing normal and disordered swallowing (i.e., screening) independent of human input, identifying a variety of swallowing physiological events as accurately as trained human judges. The system has been developed through a collaboration of data scientists, computer–electrical engineers, and speech-language pathologists. Its potential to automate dysphagia screening and contribute to evaluation lies in its noninvasive nature (wearable electronic sensors) and its growing ability to accurately replicate human judgments of swallowing data typically formed on the basis of videofluoroscopic imaging data. Potential contributions of HRCA when videofluoroscopic swallowing study may be unavailable, undesired, or not feasible for many patients in various settings are discussed, along with the development and capabilities of HRCA. The use of technological advances and wearable devices can extend the dysphagia clinician's reach and reinforce top-of-license practice for patients with swallowing disorders. 
    more » « less
  3. Abstract Nanomaterial‐based stretchable electronics composed of conductive nanomaterials in elastomer can seamlessly integrate with human skin to imperceptibly capture electrophysiological signals. Despite the use of transfer printing to form embedded structures, it remains challenging to facilely and stably integrate conductive nanomaterials with thin, low‐modulus, adhesive elastomers. Here, a facile‐yet‐simple laser‐induced graphene (LIG)‐assisted patterning and transfer method is demonstrated to integrate patterned silver nanowires onto an ultra‐low modulus silicone adhesive as ultra‐conformal epidermal electrodes. The resulting thin epidermal electrodes of ≈50 µm exhibit a low sheet resistance (0.781 Ω sq−1), tissue‐like Young's modulus (0.53 MPa), strong self‐adhesion, and excellent breathability. The breathable electrodes dynamically conformed to the skin with low contact impedance allow for long‐term, high‐fidelity monitoring of electrophysiological signals in complex environments (even during exercise and heavy sweating). Moreover, the LIG‐assisted transfer can provide a robust interface to establish a stable connection between the soft electrodes and rigid hardware. The large‐scale fabrication further provides an eight‐channel electromyography system combined with a deep learning algorithm for gesture classification and recognition with remarkable accuracy (95.4%). The results from this study also provide design guidelines and fabrication methods of the next‐generation epidermal electronics for long‐term dynamic health monitoring, prosthetic control, and human‐robot collaborations. 
    more » « less
  4. Abstract Here, an unobtrusive, adhesive‐integrated electrode array for continuous monitoring of stomach electric activity is introduced. This patient‐friendly, disposable peel‐and‐stick adhesive device represents an important advancement over existing arrays that require placement of each electrode individually and are thus also labor intensive and are in general more rigid and cumbersome. In comparison to other silver–silver chloride electrodes, this skin conformal array does not require gel and thus can withstand low impedance over the duration of long recordings. Interfacing these electrodes with miniaturized electronic recording and wireless telemetry systems has the potential to enable scalable population health opportunities to perform objective gastrointestinal assessment and optimization of treatment regimens. 
    more » « less
  5. Conventional electroencephalography (EEG) requires placement of several electrode sensors on the scalp and, accompanied by lead wires and bulky instrumentation, makes for an uncomfortable experience. Recent efforts in miniaturization and system integration have enabled smaller systems, such as wearable, in-ear EEG devices that are gaining popularity for their unobtrusive form factor. Although in-ear EEG has been demonstrated in recent works, dynamics of the ear and ear canal that directly affect electrophysiological measurements have been largely ignored. Here, we present a quantitative analysis of electrode-skin impedance for dry-contact in-ear EEG that accounts for cerumen (earwax) and electrodermal (sweat gland) response. Custom fitted earmolds with 16 embedded electrodes were developed to map the skin conductance in the ear canal of 3 subjects. In the presence of cerumen, the measured average dry-contact impedance in the ear canal was 86% higher than canals removed of cerumen. Electrodermal activity was also found to play a role in electrode-skin impedance, showing up to 25% decrease in dry-contact impedance in response to tactile stimulation. The better understanding of the dynamics of in-ear conditions serves to improve consistency and accuracy of in-ear electrophysiology. 
    more » « less