Title: Nonlinear Structural Model Parameter Updating Using Residual Drift Measurements from Sequential Seismic Events
Model parameter updating can enhance the use of nonlinear structural response simulation to guide decision-making in the post-earthquake environment. Since most structures in high seismic regions are not instrumented with sensors, the response history during ground shaking is usually not available after an earthquake. Nevertheless, technologies such as Light Detection and Ranging (LiDAR) and drone-mounted imaging devices have increased the feasibility of measuring residual deformations after the shaking has subsided. It is within this context that a framework for performing nonlinear structural model parameter updating based only on residual drift measurements is proposed. The considered setting is one where a structure is subjected to a sequence of ground motions (without repairs), whereby after each event, the structural model parameters are updated using a Bayesian formulation and the measured residual drift. The methodology is demonstrated by using experimental data from a reinforced concrete bridge pier subjected to six back-to-back ground motions with significant residual drifts recorded after the third, fourth and fifth records in the sequence. The results showed that the updating procedure is able to incrementally (after each record) improve the accuracy of both the concrete and steel model parameters which also enhanced the estimates of the simulated peak and residual drifts.  more » « less
Award ID(s):
2242767
PAR ID:
10643390
Author(s) / Creator(s):
;
Publisher / Repository:
ASCE Journal of Structural Engineering
Date Published:
Journal Name:
Journal of Structural Engineering
Volume:
151
Issue:
12
ISSN:
0733-9445
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Model parameter updating can enhance the use of nonlinear structural response simulation to guide decision-making in the post-earthquake environment. Since most structures in high seismic regions are not instrumented with sensors, the response history during ground shaking is usually not available after an earthquake. Nevertheless, technologies such as Light Detection and Ranging (LiDAR) and drone-mounted imaging devices have increased the feasibility of measuring residual deformations after the shaking has subsided. It is within this context that a framework for performing nonlinear structural model parameter updating based only on residual drift measurements is proposed. The considered setting is one where a structure is subjected to a sequence of ground motions (without repairs), whereby after each event, the structural model parameters are updated using a Bayesian formulation and the measured residual drift. The methodology is demonstrated by using experimental data from a reinforced concrete bridge pier subjected to six back-to-back ground motions with significant residual drifts recorded after the third, fourth and fifth records in the sequence. The results showed that the updating procedure is able to incrementally (after each record) improve the accuracy of both the concrete and steel model parameters which also enhanced the estimates of the simulated peak and residual drifts. 
    more » « less
  2. A series of shake table tests were recently conducted on full-scale 10-story and 6-story mass timber buildings at the 6-DOF Large High-Performance Outdoor Shaking Table facility at the University of California San Diego. Stairs, providing the primary egress in and out of a building during and after an earthquake event, were incorporated in each of these building test programs. To ensure they support the immediate recovery of building function, a variety of drift-release details were incorporated. Previous earthquake events and experimental studies have shown that stairs are among the most drift-sensitive nonstructural systems and are prone to damage, therefore relieving interstory drifts is paramount to improving their performance. To this end, the designed drift-release connections within the stairs considered the test buildings response during earthquake motions scaled at various hazard levels with expected minor and repairable damage under large earthquake loading. This paper provides an overview of the shake table test programs from the perspective of the design and performance of resilient steel stairs. 
    more » « less
  3. Abstract Near‐fault pulse‐type ground motions have characteristics that are substantially different from ordinary far‐field ground motions. It is essential to understand the unique effects of pulse‐type ground motions on structures and include the effects in seismic design. This paper investigates the effects of near‐fault pulse‐type ground motions on the structural response of a 3‐story steel structure with nonlinear viscous dampers using the real‐time hybrid simulation (RTHS) testing method. The structure is designed for 75% of the code‐specified design base shear strength. In the RTHS, the loop of action and reaction between the experimental and numerical partitions are executed in real time, accurately capturing the velocity pulse effects of pulse‐type ground motions. A set of 10 unscaled pulse‐type ground motions at the design basis earthquake (DBE) level is used for the RTHS. The test results validated that RTHS is a viable method for experimentally investigating the complicated structural behavior of structures with rate‐dependent damping devices, and showed that the dampers are essentially effective in earthquake hazard mitigation effects involving pulse‐type ground motions. The average peak story drift ratio under the set of pulse‐type ground motions is 1.08% radians with a COV value less than 0.3, which indicated that structural system would achieve the ASCE 7–10 seismic performance objective for Occupancy Category III structures under the DBE level pulse‐type ground motions. Additionally, a nonlinear Maxwell model for the nonlinear viscous dampers is validated for future structural reliability numerical studies involving pulse‐type ground motions. 
    more » « less
  4. null (Ed.)
    Nonlinear time history analyses were conducted for 5-story and 12-story prototype buildings that used post-tensioned cross-laminated timber rocking walls coupled with U-shaped flexural plates (UFPs) as the lateral force resisting system. The building models were subjected to 22 far-field and 28 near-fault ground motions, with and without directivity effects, scaled to the design earthquake and maximum considered earthquake for Seattle, with ASCE Site Class D. The buildings were designed to performance objectives that limited structural damage to crushing at the wall toes and nonlinear deformation in the UFPs, while ensuring code-based interstory drift requirements were satisfied and the post-tensioned rods remained linear. The walls of the 12-story building had a second rocking joint at midheight to reduce flexural demands in the lower stories and interstory drift in the upper stories. The interstory drift, in-plane wall shear and overturning moment, UFP deformation, and extent of wall toe crushing is summarized for each building. Near-fault ground motions with directivity effects resulted in the largest demands for the 5-story building, while the midheight rocking joint diminished the influence of ground motion directivity effects in the 12-story building. Results for both buildings confirmed that UFPs located higher from the base of the walls dissipated more energy compared to UFPs closer to the base. 
    more » « less
  5. Modern seismic resistant design has been focusing on development of cost effective structural systems which experience minimal damage during an earthquake. Unbonded post-tensioned precast concrete walls provide a suitable solution due to their self-centering behavior and their ability to undergo large nonlinear deformation with minimal damage. Several experimental and analytical investigation focusing on lateral load resisting behavior of unbonded post-tensioned precast walls has been carried out in the past two decades. These investigations have primarily focused on lateral load resistance, self-centering capacity, energy dissipation and extent of damage in confined concrete region of the wall system. Past experimental results have shown that self-centering capacity of the wall system decreases at higher lateral drifts. Particularly, rocking walls with higher energy dissipation capacity, sustain considerable residual displacement. This residual displacement in the wall system may affect the ability of the entire structure to re-center. Though increasing initial prestressing force helps in reducing residual drift, it also subjects concrete to increased axial compressive stress which may lead to premature strength degradation of confined concrete in rocking corners. Accurate prediction of expected concrete strains in confined regions during increasing drift cycle is critical in design of such wall systems. Simplified design procedures available in literature assume different values for plastic hinge length to estimate critical concrete strain values. The results from the experimental tests available in literature were analyzed, to understand the effects of energy dissipating elements on residual drift and to examine the accuracy of simplified design procedures in predicting critical concrete strain. Based on the findings, recommendations are made on design of energy dissipating elements and plastic hinge length for unbonded post-tensioned precast rocking walls. 
    more » « less