skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Fate of Exhaled Droplets From Breathing and Coughing in Supermarket Checkouts and Passenger Cars
The global pandemic of COVID-19 has highlighted the importance of understanding the role that exhaled droplets play in virus transmission in community settings. Computational Fluid Dynamics (CFD) enables systematic examination of roles the exhaled droplets play in the spread of SARS-CoV-2 in indoor environments. This analysis uses published exhaled droplet size distributions combined with terminal aerosol droplet size based on measured peak concentrations for SARS-CoV-2 RNA in aerosols to simulate exhaled droplet dispersion, evaporation, and deposition in a supermarket checkout area and rideshare car where close proximity with other individuals is common. Using air inlet velocity of 2 m/s in the passenger car and ASHRAE recommendations for ventilation and comfort in the supermarket, simulations demonstrate that exhaled droplets <20 μm that contain the majority of viral RNA evaporated leaving residual droplet nuclei that remain aerosolized in the air. Subsequently ~ 70% of these droplet nuclei deposited in the supermarket and the car with the reminder vented from the space. The maximum surface deposition of droplet nuclei/m2for speaking and coughing were 2 and 819, 18 and 1387 for supermarket and car respectively. Approximately 15% of the total exhaled droplets (aerodynamic diameters 20-700 µm) were deposited on surfaces in close proximity to the individual. Due to the non-linear distribution of viral RNA across droplet sizes, however, these larger exhaled droplets that deposit on surfaces have low viral content. Maximum surface deposition of viral RNA was 70 and 1.7 × 103virions/m2for speaking and 2.3 × 104and 9.3 × 104virions/m2for coughing in the supermarket and car respectively while the initial airborne concentration of viral RNA was 7 × 106copies per ml. Integrating the droplet size distributions with viral load distributions, this study helps explain the apparent importance of inhalation exposures compared to surface contact observed in the pandemic.  more » « less
Award ID(s):
2215705
PAR ID:
10656456
Author(s) / Creator(s):
 ;  ;  ;  
Publisher / Repository:
SAGE Publishing
Date Published:
Journal Name:
Environmental Health Insights
Volume:
17
ISSN:
1178-6302
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Various breathing and cough simulators have been used to model respiratory droplet dispersion and viral droplets, in particular for SARS-CoV-2 modeling. However, limited data are available comparing these cough simulations to physiological breathing and coughing. In this study, three different cough simulators (Teleflex Mucosal Atomization Device Nasal (MAD Nasal), a spray gun, and GloGermTM MIST) that have been used in the literature were studied to assess their physiologic relevance. Droplet size, velocity, dispersion, and force generated by the simulators were measured. Droplet size was measured with scanning electron microscopy (SEM). Slow-motion videography was used to 3D reconstruct and measure the velocity of each simulated cough. A force-sensitive resistor was used to measure the force of each simulated cough. The average size of droplets from each cough simulator was 176 to 220 µm. MAD Nasal, the spray gun, and GloGermTM MIST traveled 0.38 m, 0.89 m, and 1.62 m respectively. The average velocities for the MAD Nasal, spray gun, and GloGermTM MIST were 1.57 m/s, 2.60 m/s, and 9.27 m/s respectively, and all yielded a force of <0.5 Newtons. GloGermTM MIST and the spray gun most closely resemble physiological coughs and breathing respectively. In conclusion, none of the simulators tested accurately modeled all physiologic characteristics (droplet size, 3-D dispersion velocity, and force) of a cough, while there were various strengths and weaknesses of each method. One should take this into account when performing simulations with these devices. 
    more » « less
  2. Santos, Ricardo (Ed.)
    We developed and implemented a framework for examining how molecular assay sensitivity for a viral RNA genome target affects its utility for wastewater-based epidemiology. We applied this framework to digital droplet RT-PCR measurements of SARS-CoV-2 and Pepper Mild Mottle Virus genes in wastewater. Measurements were made using 10 replicate wells which allowed for high assay sensitivity, and therefore enabled detection of SARS-CoV-2 RNA even when COVID-19 incidence rates were relatively low (~10 −5 ). We then used a computational downsampling approach to determine how using fewer replicate wells to measure the wastewater concentration reduced assay sensitivity and how the resultant reduction affected the ability to detect SARS-CoV-2 RNA at various COVID-19 incidence rates. When percent of positive droplets was between 0.024% and 0.5% (as was the case for SARS-CoV-2 genes during the Delta surge), measurements obtained with 3 or more wells were similar to those obtained using 10. When percent of positive droplets was less than 0.024% (as was the case prior to the Delta surge), then 6 or more wells were needed to obtain similar results as those obtained using 10 wells. When COVID-19 incidence rate is low (~ 10 −5 ), as it was before the Delta surge and SARS-CoV-2 gene concentrations are <10 4 cp/g, using 6 wells will yield a detectable concentration 90% of the time. Overall, results support an adaptive approach where assay sensitivity is increased by running 6 or more wells during periods of low SARS-CoV-2 gene concentrations, and 3 or more wells during periods of high SARS-CoV-2 gene concentrations. 
    more » « less
  3. Abstract Background Airborne viral pathogens like severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be encapsulated and transmitted through liquid droplets/aerosols formed during human respiratory events. Methods The number and extent of droplets/aerosols at distances between 1 and 6 ft (0.305–1.829 m) for a participant wearing no face covering, a cotton single-layer cloth face covering, and a 3-layer disposable face covering were measured for defined speech and cough events. The data include planar particle imagery to illuminate emissions by a light-sheet and local aerosol/droplet probes taken with phase Doppler interferometry and an aerodynamic particle sizer. Results Without face coverings, droplets/aerosols were detected up to a maximum of 1.25 m (4.1ft ± 0.22–0.28 ft) during speech and up to 1.37 m (4.5ft ± 0.19–0.33 ft) while coughing. The cloth face covering reduced maximum axial distances to 0.61 m (2.0 ft ± 0.11–0.15 ft) for speech and to 0.67 m (2.2 ft ± 0.02–0.20 ft) while coughing. Using the disposable face covering, safe distance was reduced further to 0.15 m (0.50 ft ± 0.01–0.03 ft) measured for both emission scenarios. In addition, the use of face coverings was highly effective in reducing the count of expelled aerosols. Conclusions The experimental study indicates that 0.914 m (3 ft) physical distancing with face coverings is equally as effective at reducing aerosol/droplet exposure as 1.829 m (6 ft) with no face covering. 
    more » « less
  4. Abstract The fast spread of coronavirus disease 2019 (COVID‐19) constitutes a worldwide challenge to the public health, educational and trade systems, affecting the overall well‐being of human societies. The high transmission and mortality rates of this virus, and the unavailability of a vaccine or treatment, resulted in the decision of multiple governments to enact measures of social distancing. Such measures can reduce the exposure to bioaerosols, which can result in pathogen deposition in the respiratory tract of the host causing disease and an immunological response. Thus, it is important to consider the validity of the proposal for keeping a distance of at least 2 m from other persons to avoid the spread of COVID‐19. This work reviews the effect of aerodynamic diameter (size) of particles carrying RNA copies of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2). A SARS‐CoV‐2 carrier person talking, sneezing or coughing at distance of 2 m can still provide a pathogenic bioaerosol load with submicron particles that remain viable in air for up to 3 h for exposure of healthy persons near and far from the source in a stagnant environment. The deposited bioaerosol creates contaminated surfaces, which if touched can act as a path to introduce the pathogen by mouth, nose or eyes and cause disease. 
    more » « less
  5. Abstract How human respiratory physiology and the transport phenomena associated with inhaled airflow in the upper airway proceed to impact transmission of SARS-CoV-2, leading to the initial infection, stays an open question. An answer can help determine the susceptibility of an individual on exposure to a COVID-2019 carrier and can also provide a preliminary projection of the still-unknown infectious dose for the disease. Computational fluid mechanics enabled tracking of respiratory transport in medical imaging-based anatomic domains shows that the regional deposition of virus-laden inhaled droplets at the initial nasopharyngeal infection site peaks for the droplet size range of approximately 2.5–19$$\upmu $$ μ . Through integrating the numerical findings on inhaled transmission with sputum assessment data from hospitalized COVID-19 patients and earlier measurements of ejecta size distribution generated during regular speech, this study further reveals that the number of virions that may go on to establish the SARS-CoV-2 infection in a subject could merely be in the order of hundreds. 
    more » « less