Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Free, publicly-accessible full text available September 1, 2025
-
Abstract Despite the extensive developments of flexible capacitive pressure sensors, it is still elusive to simultaneously achieve excellent linearity over a broad pressure range, high sensitivity, and ultrahigh pressure resolution under large pressure preloads. Here, we present a programmable fabrication method for microstructures to integrate an ultrathin ionic layer. The resulting optimized sensor exhibits a sensitivity of 33.7 kPa −1 over a linear range of 1700 kPa, a detection limit of 0.36 Pa, and a pressure resolution of 0.00725% under the pressure of 2000 kPa. Taken together with rapid response/recovery and excellent repeatability, the sensor is applied to subtle pulse detection, interactive robotic hand, and ultrahigh-resolution smart weight scale/chair. The proposed fabrication approaches and design toolkit from this work can also be leveraged to easily tune the pressure sensor performance for varying target applications and open up opportunities to create other iontronic sensors.more » « lessFree, publicly-accessible full text available December 1, 2024
-
Transient electronic devices have shown promising applications in hardware security and medical implants with diagnosing therapeutics capabilities since their inception. Control of the device transience allows the device to “dissolve at will” after its functional operation, leading to the development of on-demand transient electronics. This review discusses the recent developments and advantages of triggering strategies ( e.g. , electrical, thermal, ultrasound, and optical) for controlling the degradation of on-demand transient electronics. We also summarize bioresorbable sensors for medical diagnoses, including representative applications in electrophysiology and neurochemical sensing. Along with the profound advancements in medical diagnosis, the commencement of therapeutic systems such as electrical stimulation and drug delivery for the biomedical or medical implant community has also been discussed. However, implementing a transient electronic system in real healthcare infrastructure is still in its infancy. Many critical challenges still need to be addressed, including strategies to decouple multimodal sensing signals, dissolution selectivity in the presence of multiple stimuli, and a complete sensing–stimulation closed-loop system. Therefore, the review discusses future opportunities in transient decoupling sensors and robust transient devices, which are selective to a particular stimulus and act as hardware-based passwords. Recent advancements in closed-loop controller-enabled electronics have also been analyzed for future opportunities of using data-driven artificial intelligence-powered controllers in fully closed-loop transient systems.more » « less
-
Abstract Monitoring nitrogen utilization efficiency and soil temperature in agricultural systems for timely intervention is essential for crop health with reduced environmental pollution. Herein, this work presents a high‐performance multi‐parameter sensor based on vanadium oxide (VOX)‐doped laser‐induced graphene (LIG) foam to completely decouple nitrogen oxides (NOX) and temperature. The highly porous 3D VOX‐doped LIG foam composite is readily obtained by laser scribing vanadium sulfide (V5S8)‐doped block copolymer and phenolic resin self‐assembled films. The heterojunction formed at the LIG/VOXinterface provides the sensor with enhanced response to NOXand an ultralow limit of detection of 3 ppb (theoretical estimate of 451 ppt) at room temperature. The sensor also exhibits a wide detection range, fast response/recovery, good selectivity, and stability over 16 days. Meanwhile, the sensor can accurately detect temperature over a wide linear range of 10–110 °C. The encapsulation of the sensor with a soft membrane further allows for temperature sensing without being affected by NOX. The unencapsulated sensor operated at elevated temperature removes the influences of relative humidity and temperature variations for accurate NOXmeasurements. The capability to decouple nitrogen loss and soil temperature paves the way for the development of future multimodal decoupled electronics for precision agriculture and health monitoring.