Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
                                            Some full text articles may not yet be available without a charge during the embargo (administrative interval).
                                        
                                        
                                        
                                            
                                                
                                             What is a DOI Number?
                                        
                                    
                                
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
- 
            Abstract Narrow bipolar events (NBEs) are impulsive and powerful intracloud discharges. Recent observations indicate that some NBEs exhibit a slanted orientation rather than strictly vertical. This paper investigates the effect of the slanted NBEs using a newly developed rebounding‐wave model. The modeling results are validated against the full‐wave Finite‐ Difference Time‐Domain method and compared with measurements for both vertical and slanted NBE cases. It is found that the inclination of the NBEs affects both the waveforms and amplitudes of the electrostatic, induction and radiation components of the electric fields at close distances (≤10 km). However, it primarily influences the amplitudes of the fields for distances beyond 50 km, where the radiation component dominates, resulting in changes of ≥30% when the slant angle exceeds 30°. The slanted rebounding‐wave model improves the agreement with respect to a purely vertical channel and can be extended to any discharge geometry at arbitrary observation distances.more » « less
- 
            Abstract Positive lightning discharges to ground (+CGs) are relatively rare and considerably less studied than negative ones (-CGs). We present observations of unusual transient phenomena occurring in +CGs and discuss their mechanisms. One of them is a brief electric coupling to a concurrent -CG initiated from a 257-m tall tower located 11 km from the +CG channel. A transient process (stroke) in the -CG flash appears to cause a transient luminosity enhancement (M-component) in the +CG channel. In the course of these essentially simultaneous transients, positive charge is in effect taken from the ground at the position of the tower and injected into the ground at the position of the +CG channel. Recoil leaders reactivating decayed +CG branches near the cloud base are each observed to cause a transient luminosity decrease (dip), as opposed to the expected luminosity increase, in the +CG main channel.more » « less
- 
            Abstract This study assesses the reliability and limitations of the Geostationary Lightning Mapper (GLM) in detecting continuing currents by comparing observations from ground‐based high‐speed cameras with GLM‐16 data. Our findings show that the GLM's one‐group detection efficiency (DE_1) is 53%, while the more stringent five‐consecutive‐group detection efficiency (DE_5) is 10%. Optical signals detected by the GLM predominantly occur during the early stages of continuing currents. Additionally, there is a notable disparity in detection efficiencies between positive and negative continuing currents, with positive continuing currents being detected more frequently. The application of the logistic regression model developed by Fairman and Bitzer (2022) further illustrates the limitations in continuing current identification. The study underscores the challenges of relying solely on satellite data to monitor and analyze continuing currents, emphasizing the need for advancements in detection technologies and methodologies to reliably detect continuing current at a large spatial scale.more » « less
- 
            Abstract To know if a lightning discharge reaches the ground or remains within the thundercloud is critical for lightning safety as cloud‐to‐ground lightning poses the greatest threat to life and property. The current classification methods for most lightning detection networks, which are based on the classification of electromagnetic pulses produced by lightning, still have plenty of room to improve, including some known issues to be addressed. We present a machine‐learning approach to classify lightning discharges. The classification model used in this study is based on Support Vector Machines (SVMs). Compared with traditional multiparameter methods, our algorithm does not require extraction of individual pulse parameters and additionally provides a probability for each prediction. Using a representative lightning pulse data collected by the Cordoba Marx Meter Array in Argentina, we found the classification accuracy of our machine‐learning algorithm to be 97%, which is higher than that for the existing lightning detection networks.more » « less
- 
            Abstract A new automated method to retrieve charge layer polarity from flashes, named Chargepol, is presented in this paper. Using data from the NASA Lightning Mapping Array (LMA) deployed during the Remote sensing of Electrification, Lightning, And Mesoscale/microscale Processes with Adaptive Ground Observations (RELAMPAGO) field campaign in Cordoba, Argentina, from November 2018 to April 2019, this method estimates the polarity of vertical charge distributions and their altitudes and thicknesses (or vertical depth) using the very‐high frequency (VHF) source emissions detected by LMAs. When this method is applied to LMA data for extended periods of time, it is capable of inferring a storm's bulk electrical charge structure throughout its life cycle. This method reliably predicted the polarity of charge within which lightning flashes propagated and was validated in comparison to methods that require manual assignment of polarities via visual inspection of VHF lightning sources. Examples of normal and anomalous charge structures retrieved using Chargepol for storms in Central Argentina during RELAMPAGO are presented for the first time. Application of Chargepol to five months of LMA data in Central Argentina and several locations in the United States allowed for the characterization of the charge structure in these regions and for a reliable comparison using the same methodology. About 13.3% of Cordoba thunderstorms were defined by an anomalous charge structure, slightly higher than in Oklahoma (12.5%) and West Texas (11.1%), higher than Alabama (7.3%), and considerably lower than in Colorado (82.6%). Some of the Cordoba anomalous thunderstorms presented enhanced low‐level positive charge, a feature rarely if ever observed in Colorado thunderstorms.more » « less
- 
            Abstract Previous studies have shown that subsequent leaders in positive cloud‐to‐ground lightning (+CG) flashes rarely traverse pre‐existing channels to ground. In this paper, we present evidence that this actually can be common, at least for some thunderstorms. Observations of +CG flashes in a supercell storm in Argentina by Córdoba Argentina Marx Meter Array (CAMMA) are presented, in which 54 (64%) of 84 multiple‐stroke +CG flashes had subsequent leaders following a pre‐existing channel to ground. These subsequent positive leaders are found to behave similarly to their negative counterparts, including propagation speeds along pre‐existing channels with a median of 8 × 106 m/s, which is comparable to that of negative dart leaders. Two representative multiple‐stroke +CG flashes are presented and discussed in detail. The observations reported herein call for an update to the traditional explanation of the disparity between positive and negative lightning.more » « less
 An official website of the United States government
An official website of the United States government 
				
			 
					 
					
