Digital image correlation (DIC) is an increasingly popular and effective non-contact method for measuring full-field displacements and strains of deformable bodies under load. Current DIC methods applied to bodies undergoing large displacements and rotations require a large measurement area for both the reference (i.e., undeformed) image and the deformed images. This can limit the resulting resolution of the displacement and strain fields. To address this issue, we propose a two-stage dynamic DIC method capable of measuring displacements and strains under material convection with high resolution. During the first stage, the reference image is assembled from smaller, high-resolution images of the undeformed object obtained using a spatially-fixed or moving frame. Following capture, each sub-image is rigidly translated and rotated into its appropriate place, thereby producing a full, high-resolution image of the reference body. In stage two, images of the loaded and deformed body, again obtained using a small camera frame with high resolution, are aligned with matching regions of the undeformed composite image using BRISK feature detection before performing DIC.We demonstrate the method on a contact problem whereby an elastomeric roller travels along a rigid surface. In doing so, we obtain fine resolution measurements of the state of strain of the region of the roller sidewall in contact with the substrate, even as new material convects through the region of interest. We present these measurements as a series of images and videos capturing strain evolution as the roller transitions from static loads to a fully dynamic steady-state, documenting the effectiveness of the method.
more »
« less
Application of Digital Image Correlation (DIC) to the Measurement of Strain Concentration of a PVA Dual-Crosslink Hydrogel Under Large Deformation
Hydrogels are a class of soft, highly deformable materials formed by swelling a network of polymer chains in water. With mechanical properties that mimic biological materials, hydrogels are often proposed for load bearing biomedical or other applications in which their deformation and failure properties will be important. To study the failure of such materials a means for the measurement of deformation fields beyond simple uniaxial tension tests is required. As a non-contact, full-field deformation measurement method, Digital Image Correlation (DIC) is a good candidate for such studies. The application of DIC to hydrogels is studied here with the goal of establishing the accuracy of DIC when applied to hydrogels in the presence of large strains and large strain gradients. Experimental details such as how to form a durable speckle pattern on a material that is 90% water are discussed. DIC is used to measure the strain field in tension loaded samples containing a central hole, a circular edge notch and a sharp crack. Using a nonlinear, large deformation constitutive model, these experiments are modeled using the finite element method (FEM). Excellent agreement between FEM and DIC results for all three geometries shows that the DIC measurements are accurate up to strains of over 10, even in the presence of very high strain gradients near a crack tip. The method is then applied to verify a theoretical prediction that the deformation field in a cracked sample under relaxation loading, i.e. constant applied boundary displacement, is stationary in time even as the stress relaxes by a factor of three.
more »
« less
- Award ID(s):
- 1537087
- PAR ID:
- 10109914
- Date Published:
- Journal Name:
- Experimental Mechanics
- ISSN:
- 0014-4851
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Strain sensors are the primary, direct sensing element in many sensors with applications in robotics, wearable sensors, structural health monitoring, and beyond. Cutting edge applications are increasing demand for sensors that can survive and measure large strains (> 5%). Presently, the most common strain sensors are composed of a serpentine metal foil which can survive strains up to about 5% with a gauge factor (GF) of about 2 (measured as change in resistance divided by initial resistance all over strain). Research into nanoparticle-based strain sensors commonly reports surviving strains up to 50% and gauge factors around 200. Unfortunately, most nanoparticle-based strain sensors are composed of expensive, toxic materials and require high precision synthesis methods. The reduced Graphene Oxide (rGO) based sensors can be synthesized easily with common materials and methods. Study of strain sensing capabilities have revealed that rGO strain sensors can survive strains beyond 15% with gauge factors (sensitivity) on the order of 200. Suspensions of graphene oxide (GO)’s flakes were deposited on flexible Polydimethylsiloxane (PDMS) substrates to create specimens with different area densities of 0.69, 0.80 and 091 mg/cm2 of GO. Specimens were thermally reduced to create rGO-based strain sensors. Resulting sensors were tested under tension applied at a rate of 0.1 mm/sec starting from 0% strain until failure. Resistance of the sensors in the direction aligned with the direction of the applied tension were measured at each 1 mm-increment of tension. Sensitivity and the strain to failure of the sensor were calculated and compared in specimens with different GO area densities. Our study suggests that with increasing the area density of graphene oxide (GO) during the synthesis of rGO, the survivability of the rGO subjected to large strains can be improved while still demonstrating a high sensitivity. This study can help tailor rGO-based strain sensors especially to the applications where high strain survival (> 30%) is required while benefiting from a reasonably good GF (> 30).more » « less
-
Brillouin scattering-based distributed fiber optic sensing (Brillouin-DFOS) technology is widely used in health monitoring of large-scale structures with the aim to provide early warning of structural degradation and timely maintenance and renewal. Material cracking is one of the key mechanisms that contribute to structural failure. However, the conventional strain measurement using the Brillouin-DFOS system has a decimeter-order spatial resolution, and therefore it is difficult to measure the highly localized strain generated by a sub-millimeter crack. In this study, a new crack analysis method based on Brillouin scattering spectrum (BSS) data is proposed to overcome this spatial resolution-induced measurement limitation. By taking the derivative of the BSS data and tracking their local minimums, the method can extract the maximum strain within the spatial resolution around the measurement points. By comparing the variation of the maximum strain within the spatial resolution around different measurement points along the fiber, cracks can be located. The performance of the method is demonstrated and verified by locating and quantifying a small gap created between two wood boards when one of the wood boards is pushed away from the other. The test result verifies the accuracy of the crack strain quantification of the method and proves its capability to measure a sub-millimeter crack. The method is also applied to a thin bonded concrete overlay of asphalt pavement field experiment, in which the growth of a transverse joint penetrating through the concrete–asphalt interface was monitored. The method successfully locates the position, traces the strain variation, and estimates the width of a crack less than [Formula: see text] wide using a Brillouin-DFOS system with [Formula: see text] spatial resolution.more » « less
-
Digital image correlation (DIC) is a non-destructive and non-contact optical technique to measure deformation and strain of materials. The method is based on optically tracking the displacements of a speckle pattern created on the material surface. In the case of soft tissues such as mouse aorta, there are several advantages to using DIC since it can provide local, rather than global, deformations and it is suitable for large strain measurements, typical of soft tissues taken to failure [1] [2]. For the optimal use of DIC, several requirements should be met for speckle patterning: 1) randomness, 2) high contrast, 3) appropriate size of speckle in the field of view (3-5 pixels), and 4) firm attachment of speckle to specimen during deformation. In previous DIC studies of soft tissues, the methods employed to create a speckle pattern include the use of an airbrush to spray dye or paint on the specimen, or coating the sample with toner powder. However, biological samples must be partially dehydrated before applying paint which may affect the mechanical properties of the specimen, and toner powder is too hydrophobic to adhere well on specimens when submerged in aqueous solution during mechanical testing. In addition, it is difficult to evenly distribute paint or toner powder on the surface of a hydrated biological specimen [2]. Therefore, a novel method utilizing colloidal gold particles to create a speckle pattern on mouse aorta is proposed in this work.more » « less
An official website of the United States government

