We present enabling experimental tools and atom interferometer implementations in a vertical “fountain” geometry with ytterbium Bose–Einstein condensates. To meet the unique challenge of the heavy, non-magnetic atom, we apply a shaped optical potential to balance against gravity following evaporative cooling and demonstrate a double Mach–Zehnder interferometer suitable for applications such as gravity gradient measurements. Furthermore, we also investigate the use of a pulsed optical potential to act as a matter wave lens in the vertical direction during expansion of the Bose–Einstein condensate. This method is shown to be even more effective than the aforementioned shaped optical potential. The application of this method results in a reduction of velocity spread (or equivalently an increase in source brightness) of more than a factor of five, which we demonstrate using a two-pulse momentum-space Ramsey interferometer. The vertical geometry implementation of our diffraction beams ensures that the atomic center of mass maintains overlap with the pulsed atom optical elements, thus allowing extension of atom interferometer times beyond what is possible in a horizontal geometry. Our results thus provide useful tools for enhancing the precision of atom interferometry with ultracold ytterbium atoms.
more »
« less
A compact high-precision periodic-error-free heterodyne interferometer
We present the design, bench-top setup, and experimental results of a compact heterodyne interferometer that achieves picometer-level displacement sensitivities in air over frequencies above 100 MHz. The optical configuration with spatially separated beams prevents frequency and polarization mixing, and therefore eliminates periodic errors. The interferometer is designed to maximize common-mode optical laser beam paths to obtain high rejection of environmental disturbances, such as temperature fluctuations and acoustics. The results of our experiments demonstrate the short- and long-term stabilities of the system during stationary and dynamic measurements. In addition, we provide measurements that compare our interferometer prototype with a commercial system, verifying our higher sensitivity of 3 pm, higher thermal stability by a factor of two, and periodic-error-free performance.
more »
« less
- PAR ID:
- 10161523
- Publisher / Repository:
- Optical Society of America
- Date Published:
- Journal Name:
- Journal of the Optical Society of America A
- Volume:
- 37
- Issue:
- 9
- ISSN:
- 1084-7529; JOAOD6
- Format(s):
- Medium: X Size: Article No. B11
- Size(s):
- Article No. B11
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
We report an Optical Differentiation Wavefront Sensor based on a telephoto lens system and binary pixelated filters. It provides a five-fold reduction in the system length compared to a 4fsystem with identical effective focal length. Measurements of phase plates with this system are compared to measurements performed with a commercial low-coherence interferometer. The telephoto-lens-based system can measure wavefronts with accuracy better thanλ/10 Root Mean Squared (RMS) atλ=633 nm. Experimental investigation shows that the system has a high tolerance to components alignment errors.more » « less
-
We present measurements of an optomechanical accelerometer for monitoring low-frequency noise in gravitational wave detectors, such as ground motion. Our device measures accelerations by tracking the test-mass motion of a 4.7 Hz mechanical resonator using a heterodyne interferometer. This resonator is etched from monolithic fused silica, an under-explored design in low-frequency sensors, allowing a device with a noise floor competitive with existing technologies but with a lighter and more compact form. In addition, our heterodyne interferometer is a compact optical assembly that can be integrated directly into the mechanical resonator wafer to further reduce the overall size of our accelerometer. We anticipate this accelerometer to perform competitively with commercial seismometers, and benchtop measurements show a noise floor reaching 82 pico-g Hz−1/2 sensitivities at 0.4 Hz. Furthermore, we present the effects of air pressure, laser fluctuations, and temperature to determine the stability requirements needed to achieve thermally limited measurements.more » « less
-
Modern short-range gravity experiments that seek to test the Newtonian inverse-square law or weak equivalence principle of general relativity typically involve measuring the minute variations in the twist angle of a torsion pendulum. Motivated by various theoretical arguments, recent efforts largely focus on measurements with test mass separations in the sub-millimeter regime. To measure the twist, many experiments employ an optical autocollimator with a noise performance of ∼300 nrad/Hz in the 0.1–10 mHz band, enabling a measurement uncertainty of a few nanoradians in a typical integration time. We investigated an alternative method for measuring a small twist angle through the construction of a modified Michelson interferometer. The main modification is the introduction of two additional arms that allow for improved angular alignment. A series of detectors and LabView software routines were developed to determine the orientation of a mirror attached to a sinusoidally driven rotation stage that oscillated with an amplitude of 0.35 mrad and a period of 200 s. In these measurements, the resolution of the interferometer is 8.1 μrad per fringe, while its dynamic range spanned 0.962 mrad. We compare the performance of this interferometric optical system to existing autocollimator-based methods, discussing its implementation, possible advantages, and future potential, as well as disadvantages and limitations.more » « less
-
Abstract We discuss the design, construction, and operation of a new intensity interferometer, based on the campus of Southern Connecticut State University in New Haven, Connecticut. While this paper will focus on observations taken with an original two-telescope configuration, the current instrumentation consists of three portable 0.6 m Dobsonian telescopes with single-photon avalanche diode detectors located at the Newtonian focus of each telescope. Photons detected at each station are time stamped and read out with timing correlators that can give cross-correlations in timing to a precision of 48 ps. We detail our observations to date with the system, which has now been successfully used at our university in 16 nights of observing. Components of the instrument were also deployed on one occasion at Lowell Observatory, where the Perkins and Hall telescopes were made to function as an intensity interferometer. We characterize the performance of the instrument in detail. In total, the observations indicate the detection of a correlation peak at the level of 6.76σwhen observing unresolved stars, and consistency with partial or no detection when observing at a baseline sufficient to resolve the star. Using these measurements, we conclude that the angular diameter of Arcturus is larger than 15 mas and that of Vega is between 0.8 and 17 mas. While the uncertainties are large at this point, both results are consistent with measures from amplitude-based long baseline optical interferometers.more » « less