Title: On the Nonlinear Mode-Coupling in Ultra Precision Manufacturing Machines: Experimental and Analytical Analyses
Abstract

Recent studies in passively-isolated systems have shown that mode coupling is desirable for best vibration suppression, thus refuting the long-standing rule of mode decoupling. However, these studies have ignored the non-linearities in the isolators. In this work, we consider stiffness nonlinearity from pneumatic isolators and study the nonlinear free undamped vibrations of a passively-isolated ultra-precision manufacturing (UPM) machine. Experimental analysis is conducted to guide the mathematical formulation. The system comprises linearly and nonlinearly coupled in-plane horizontal and rotational motion of the UPM machine with quadratic nonlinear stiffness from the isolators. We present closed-form expressions using the method of multiple scales for two cases viz. the non-resonant case and the bounded internal resonance case. We validate our theoretical findings through direct numerical simulations. For the non-resonant case, we show that the system behaves similar to a linear system. However, for the nearly internal resonance case, we demonstrate strong energy exchange between the modes stemming from nonlinear mode coupling. We further study the effect of nonlinear mode coupling on the vibration isolation performance and demonstrate that mode coupling is not always desirable.

 
more » « less
Award ID(s):
2000984
NSF-PAR ID:
10229180
Author(s) / Creator(s):
; ; ;
Date Published:
Journal Name:
Proceedings of the ASME 2020 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Floor isolation systems (FISs) are used to mitigate earthquake-induced damage to sensitive building contents and equipment. Traditionally, the isolated floor and the primary building structure (PS) are analyzed independently, assuming the PS response is uncoupled from the FIS response. Dynamic coupling may be non-negligible when nonlinearities are present under large deflections at strong disturbance levels. This study investigates a multi-functional FIS that functions primarily as an isolator (i.e., attenuating total acceleration sustained by the isolated equipment) at low-to-moderate disturbance levels, and then passively adapt under strong disturbances to function as a nonlinear (vibro-impact) dynamic vibration absorbers to protect the PS (i.e., reducing inter-story drifts). The FIS, therefore, functions as a dual-model vibration isolator/absorber system, with displacement dependent response adaptation. A scale experimental model—consisting of a three-story frame and an isolated mass—is used to demonstrate and evaluate the design methodology via shake table tests. The properties of the 3D-printed rolling pendulum (RP) bearing, the seismic gap, and the impact mechanism are optimized to achieve the desired dual-mode performance. A suite of four ground motions with varying spectral qualities are used, and their amplitudes are scaled to represent various hazards—from service level earthquake (SLE), to design basis earthquake (DBE), and even maximum considered earthquake (MCE). The performance of the multi-functional FIS is established and is described in this paper. 
    more » « less
  2. Abstract

    We investigate the effectiveness of a vibration absorber on the vortex-induced vibration response of turbine blades during the frequency lock-in phase. A reduced-order model of a turbine blade and van der Pol oscillator is used to represent the fluid–blade interaction caused by the vortex shedding. A spring-mass-damper system is considered to model the vibration absorber. The advantage of the vibration absorber is demonstrated by simulating the nonlinear coupled four-degree-of-freedom aeroelastic system for the different sets of system parameters. We observe the dominance of a nonlinear vibration absorber over the linear vibration absorber only for the higher coupling parameter values. The analytical solution of the nonlinear coupled system is obtained through the method of multiple scales for the case of 1:1 internal resonance to identify the critical design parameters of the vibration absorber. We observe the high sensitivity of the system's frequency response to the distance of the vibration absorber from the elastic axis, along with the absorber's damping, stiffness, and mass. Finally, we perform a parametric analysis on the lock-in of the stability region to better understand the effect of the vibration absorber on the instability region.

     
    more » « less
  3. Abstract

    The inerter pendulum vibration absorber (IPVA) is integrated between a spar and an annulus floater using a ball-screw mechanism to study its wave energy conversion potential. Hydrodynamic stiffness, added mass, and radiation damping effects on the spar-floater system are characterized using the boundary element method. It is found that a 1:2 internal resonance via a period-doubling bifurcation in the system is responsible for nonlinear energy transfer between the spar-floater system and the pendulum vibration absorber. This nonlinear energy transfer occurs when the primary harmonic solution of the system becomes unstable due to the 1:2 internal resonance phenomenon. The focus of this paper is to analyze this 1:2 internal resonance phenomenon near the first natural frequency of the system. The IPVA system when integrated with the spar-floater system is shown to outperform a linear coupling between the spar and the floater both in terms of the response amplitude operator (RAO) of the spar and one measure of the energy conversion potential of the system. Finally, experiments are performed on the IPVA system integrated with single-degree-of-freedom system (without any hydrodynamic effects) to observe the 1:2 internal resonance phenomenon and the nonlinear energy transfer between the primary mass and the pendulum vibration absorber. It is shown experimentally that the IPVA system outperforms a linear benchmark in terms of vibration suppression due to the energy transfer phenomenon.

     
    more » « less
  4. Abstract

    Several investigators have taken advantage of electromagnetic shunt-tuned mass dampers to achieve concurrent vibration mitigation and energy harvesting. For nonlinear structures such as the Duffing oscillator, it has been shown that the novel nonlinear electromagnetic resonant shunt-tuned mass damper inerter (NERS-TMDI) can mitigate vibration and extract energy for a wider range of frequencies and forcing amplitudes when compared to competing technologies. However, nonlinear systems such as the NERS-TMDI are known to exhibit complex stability behavior, which can strongly influence their performance in simultaneous vibration control and energy harvesting. To address this problem, this paper conducts a global stability analysis of the novel NERS-TMDI using three approaches: the multi-parametric recursive continuationWe emphasize that these assume method, Floquet theory, and Lyapunov exponents. A comprehensive parametric analysis is also performed to evaluate the impact of key design parameters on the global stability of the system. The outcome indicates the existence of complex nonlinear behavior, such as detached resonance curves, and the transition of periodic stable solutions to chaotic solutions. Additionally, a parametric study demonstrates that the nonlinear stiffness has a minimal impact on the linear stability of the system but can significantly impact the nonlinear stability performance, while the transducer coefficient has an impact on the linear and nonlinear stability NERS-TMDI. Finally, the global sensitivity analysis is performed relative to system parameters to quantify the impact of uncertainty in system parameters on the dynamics. Overall, our findings show that simultaneous vibration control and energy harvesting come with a considerable instability trade-off that limits the range of operation of the NERS-TMDI.

     
    more » « less
  5. Abstract

    Floor isolation systems (FISs) are used to mitigate earthquake‐induced damage to sensitive building contents. Dynamic coupling between the FIS and primary structure (PS) may be nonnegligible or even advantageous when strong nonlinearities are present under large isolator displacements. This study investigates the influence of dynamic coupling between the PS and FIS in the presence of nonsmooth (impact‐like) nonlinearity in the FIS under intense earthquakes. Using component mode analysis, a nonlinear reduced order model of the combined FIS–PS system is developed by coupling a condensed model of the linear PS to the nonlinear FIS. A bilinear Hertz‐type contact model is assumed for the FIS, with the gap and the impact stiffness and damping providing parametric variation. The performance of the FIS–PS system is quantified through a multiobjective, risk‐based design criterion considering both the total acceleration sustained by the isolated mass under a service‐level earthquake and the interstory drift under a maximum considered earthquake. The results of a parametric study shed light on understanding the valid range that the decoupled approach can be reliably applied for nonlinear FISs experiencing impacts. It is also shown that the nonlinear FIS can be tuned in such a way to mitigate seismic responses of the supporting PS under strong shaking, in addition to protecting the isolated mass at low to moderate shaking. The FIS, therefore, functions as a dual‐mode vibration isolator/absorber system, with displacement‐dependent response adaptation. Guidelines to the optimal tuning of such a dual‐mode system are presented based on the risk‐based stochastic design optimization.

     
    more » « less