Title: Estimation of Background Medium’s Properties in Microwave Holographic Imaging
In this paper, an approach is proposed to enhance the images produced by holographic microwave imaging technique. The approach estimates the electrical properties of the background medium. For that, first, we assumed that the background properties are within a pre-known range. Then, wideband holographic imaging technique is applied to two sets of frequencies to reconstruct two sets of images for assumed property values within the pre-determined range. An error is computed to record the differences between the two sets of images. The error is expected to be minimum at the true values of the background medium’s properties. Simulation and experimental results demonstrate the validity of the proposed technique.  more » « less
Award ID(s):
1920098
PAR ID:
10248771
Author(s) / Creator(s):
;
Date Published:
Journal Name:
2021 IEEE 21st Annual Wireless and Microwave Technology Conference (WAMICON)
Page Range / eLocation ID:
1 to 4
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. In this communication, we propose a technique to enhance the quality of images obtained from holographic microwave imaging. It is based on estimating the electrical properties of the background medium. To accomplish that, background properties to be estimated are assumed to be within a pre-known range. Then, two sets of frequencies are employed in wideband holographic imaging and images are reconstructed from each set and for assumed property values within the pre-determined range. An error is calculated according to the differences between the two sets of images. The error is expected to be minimum at the true values of the background medium’s properties. The estimated properties, in turn, are used to reconstruct images with the best quality. The validity of the proposed technique is demonstrated via simulation and experimental results. 
    more » « less
  2. Digital holographic microscopy (DHM) is a cutting-edge interferometric technique to recover the complex wavefield scattered by microscopic samples from digitally recorded intensity patterns. In off-axis DHM, the challenge is digitally generating the reference wavefront replica to compensate for the tilt between the interfering waves. Current methods to estimate the reference wavefront's parameters rely on brute-force grid searches or heuristics algorithms. Whereas brute-forced searches are time-consuming and impractical for video-rate quantitative phase imaging and analysis, applying heuristics methods in holographic videos is limited since the phase background level occasionally changes between frames. A semi-heuristic phase compensation (SHPC) algorithm is proposed to address these challenges to reconstruct phase images with minimum distortion in the full field-of-view (FOV) from holograms recorded by a telecentric off-axis digital holographic microscope. The method is tested with a USAF test target, smearing red blood cells and alive human sperm. The SHPC method provides accurate phase maps as the reference brute-force method but with a 92-fold reduction in processing time. Furthermore, this method was tested for reconstructing experimental holographic videos of dynamic specimens, obtaining stable phase values and minimal differences in the background between frames. This proposed method provides state-of-the-art phase reconstructions with high accuracy and stability in holographic videos, allowing the successful XYZ tracking of single-moving sperm cells. 
    more » « less
  3. Single-shot two-dimensional (2D) phase retrieval (PR) can recover the phase shift distribution within an object from a single 2D x-ray phase contrast image (XPCI). Two competing XPCI imaging modalities often used for single-shot 2D PR to recover material properties critical for predictive performance capabilities are: speckle-based (SP-XPCI) and propagation-based (PB-XPCI) XPCI imaging. However, PR from SP-XPCI and PB-XPCI images are, respectively, limited to reconstructing accurately slowly and rapidly varying features due to noise and differences in their contrast mechanisms. Herein, we consider a combined speckle- and propagation-based XPCI (SPB-XPCI) image by introducing a mask to generate a reference pattern and imaging in the near-to-holographic regime to induce intensity modulations in the image. We develop a single-shot 2D PR method for SPB-XPCI images of pure phase objects without imposing restrictions such as object support constraints. It is compared against PR methods inspired by those developed for SP-XPCI and PB-XPCI on simulated and experimental images of a thin glass shell before and during shockwave compression. Reconstructed phase maps show improvements in quantitative scores of root-mean-square error and structural similarity index measure using our proposed method. 
    more » « less
  4. null (Ed.)
    Routine blood pressure (BP) measurement in pregnancy is commonly performed using automated oscillometric devices. Since no wireless oscillometric BP device has been validated in preeclamptic populations, a simple approach for capturing readings from such devices is needed, especially in low-resource settings where transmission of BP data from the field to central locations is an important mechanism for triage. To this end, a total of 8192 BP readings were captured from the Liquid Crystal Display (LCD) screen of a standard Omron M7 self-inflating BP cuff using a cellphone camera. A cohort of 49 lay midwives captured these data from 1697 pregnant women carrying singletons between 6 weeks and 40 weeks gestational age in rural Guatemala during routine screening. Images exhibited a wide variability in their appearance due to variations in orientation and parallax; environmental factors such as lighting, shadows; and image acquisition factors such as motion blur and problems with focus. Images were independently labeled for readability and quality by three annotators (BP range: 34–203 mm Hg) and disagreements were resolved. Methods to preprocess and automatically segment the LCD images into diastolic BP, systolic BP and heart rate using a contour-based technique were developed. A deep convolutional neural network was then trained to convert the LCD images into numerical values using a multi-digit recognition approach. On readable low- and high-quality images, this proposed approach achieved a 91% classification accuracy and mean absolute error of 3.19 mm Hg for systolic BP and 91% accuracy and mean absolute error of 0.94 mm Hg for diastolic BP. These error values are within the FDA guidelines for BP monitoring when poor quality images are excluded. The performance of the proposed approach was shown to be greatly superior to state-of-the-art open-source tools (Tesseract and the Google Vision API). The algorithm was developed such that it could be deployed on a phone and work without connectivity to a network. 
    more » « less
  5. With the significant growth in the use of non-metallic composite materials, the demands for new and robust non-destructive testing methodologies is high. Microwave imaging has attracted a lot of attention recently for such applications. This is in addition to the biomedical imaging applications of microwave that are also being pursued actively. Among these efforts, in this paper, we propose a compact and cost-effective three-dimensional microwave imaging system based on a fast and robust holographic technique. For this purpose, we employ narrow-band microwave data, instead of wideband data used in previous three-dimensional cylindrical holographic imaging systems. Three-dimensional imaging is accomplished by using an array of receiver antennas surrounding the object and scanning that along with a transmitter antenna over a cylindrical aperture. To achieve low cost and compact size, we employ off-the-shelf components to build a data acquisition system replacing the costly and bulky vector network analyzers. The simulation and experimental results demonstrate the satisfactory performance of the proposed imaging system. We also show the effect of number of frequencies and size of the objects on the quality of reconstructed images. 
    more » « less