Title: CMOS Electrochemical Imaging Arrays for the Detection and Classification of Microorganisms
Microorganisms account for most of the biodiversity on earth. Yet while there are increasingly powerful tools for studying microbial genetic diversity, there are fewer tools for studying microorganisms in their natural environments. In this paper, we present recent advances in CMOS electrochemical imaging arrays for detecting and classifying microorganisms. These microscale sensing platforms can provide non-optical measurements of cell geometries, behaviors, and metabolic markers. We review integrated electronic sensors appropriate for monitoring microbial growth, and present measurements of single-celled algae using a CMOS sensor array with thousands of active pixels. Integrated electrochemical imaging can contribute to improved medical diagnostics and environmental monitoring, as well as discoveries of new microbial populations.  more » « less
Award ID(s):
2027108
PAR ID:
10283528
Author(s) / Creator(s):
; ; ; ; ;
Date Published:
Journal Name:
2021 IEEE International Symposium on Circuits and Systems (ISCAS)
Page Range / eLocation ID:
1 to 5
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. While classical electrochemical impedance spectroscopy (EIS) focuses on measurements from a single working electrode, dense active microelectrode arrays offer opportunities for new modes of sensing. Here we present experimental results with an integrated sensor array for electrochemical imaging. The system uses a 100 x 100 custom CMOS electrode array with 10 micron pixels, which measures impedance at frequencies up to 100 MHz. The sensor chip is uniquely designed to take advantage of the electrostatic coupling between groups of nearby pixels to re-shape the local electric field. Multiple bias voltages and clock phases create new types of signal diversity that will enable enhanced sensing modes for computational imaging and impedance tomography. 
    more » « less
  2. Soil health is a complex phenomenon that reflects the ability of soil to support both plant growth and other ecosystem functions. To our knowledge, research on extracellular electron transfer processes in soil environments is limited and could provide novel knowledge and new ways of monitoring soil health. Electrochemical activities in the soil can be studied by inserting inert electrodes. Once the electrode is polarized to a favorable potential, nearby microorganisms attach to the electrodes and grow as biofilms. Biofilms are a major part of the soil and play critical roles in microbial activity and community dynamics. Our work aims to investigate the electrochemical behavior of healthy and unhealthy soils using chronoamperometry and cyclic voltammetry. We developed a bioelectrochemical soil reactor for electrochemical measurements using healthy and unhealthy soils taken from the Cook Agronomy Farm Long-Term Agroecological Research site; the soils showed similar physical and chemical characteristics, but there was higher plant growth where the healthy soil was taken. Using carbon cloth electrodes installed in these soil reactors, we explored the electrochemical signals in these two soils. First, we measured redox variations by depth and found that reducing conditions were prevalent in healthy soils. Current measurements showed distinct differences between healthy and unhealthy soils. Scanning electron microscopy images showed the presence of microbes attached to the electrode for healthy soil but not for unhealthy soil. Glucose addition stimulated current in both soil types and caused differences in cyclic voltammograms between the two soil types to converge. Our work demonstrates that we can use current as a proxy for microbial metabolic activity to distinguish healthy and unhealthy soil. 
    more » « less
  3. This paper presents a 100 x 100 super-resolution integrated sensor array for microscale electrochemical impedance spectroscopy (EIS) imaging. The system is implemented in 180 nm CMOS with 10 x 10 micron pixels. Rather than treating each electrode independently, the sensor is designed to measure the mutual capacitance between programmable sets of pixels. Multiple spatially-resolved measurements can then be computationally combined to produce super-resolution impedance images. Experimental measurements of sub-cellular permittivity distributions within single algae cells demonstrate the potential of this new approach. 
    more » « less
  4. This review presents current knowledge on applying bioelectrochemical sensors to monitor soil fertility through microbial activity and discusses future perspectives. Soil microbial activity is considered an indicator of soil fertility due to the interconnected relationship between soil nutrient composition, microbiome, and plant productivity. Similarities between soils and bioelectrochemical reactors provide the foundation for the design of bioelectrochemical sensors driven by microorganisms enriched as electrochemically active biofilms on polarized electrodes. The biofilm can exchange electrons with electrodes and metabolites with the nearby microbiome to generate electrochemical signals that inform of microbiome functions and nutrient bioavailability. Such mechanisms can be used as a bioelectrochemical sensor for proxy monitoring of soil fertility to address the need for real-time monitoring of soils. 
    more » « less
  5. Lab-on-CMOS is an instrumentation technology that combines miniaturized bioanalytical hardware with complementary metal-oxide semiconductor (CMOS) electronics to provide integrated biosensing in a compact format. This paper focuses on a class of lab-on-CMOS systems that utilize capacitance sensing as a means to monitor cell cultures and track cell proliferation, as well as other cell life-cycle events. In this paradigm, changes in interfacial capacitance result from the activity of adherent cells at a bioelectronic interface. These changes are mapped to cell proliferation or life-cycle events using ground-truth measurements such as live cell imaging from real-time microscopy. This paper identifies instrumentation challenges that arise from conducting these ground-truth measurements in a calibrated cell culture environment, i.e., when the lab-on-CMOS system is deployed inside a CO2 cell culture incubator. In particular, we provide a detailed study of evaporation and focus degradation mitigation techniques for application in-incubator live cell imaging during lab-on-CMOS capacitance sensor calibration tasks. We show that autofocusing the microscopy column and provisioning the lab-on-CMOS with an immersion lid are two approaches that significantly improve the quality of live cell imaging ground-truth measurements over long periods. 
    more » « less