Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 11:00 PM ET on Thursday, November 12th until 12:00 AM ET on Friday, November 13th due to maintenance. We apologize for the inconvenience.


Title: Significance of Vocal Tract Geometrical Variations and Loudness on Airflow and Droplet Dispersion in a Two-Dimensional Representation of [F]
Abstract The significance of respiratory droplet transmission in spreading respiratory diseases such as COVID-19 has been identified by researchers. Although one cough or sneeze generates a large number of respiratory droplets, they are usually infrequent. In comparison, speaking and singing generate fewer droplets, but occur much more often, highlighting their potential as a vector for airborne transmission. However, the flow dynamics of speech and the transmission of speech droplets have not been fully investigated. To shed light on this topic, two-dimensional geometries of a vocal tract for a labiodental fricative [f] were generated based on real-time MRI of a subject during pronouncing [f]. In these models, two different curvatures were considered for the tip tongue shape and the lower lip to highlight the effects of the articulator geometries on transmission dynamics. The commercial ANSYS-Fluent CFD software was used to solve the complex expiratory speech airflow trajectories. Simultaneously, the discrete phase model of the software was used to track submicron and large size respiratory droplets exhaled during [f] utterance. The simulations were performed for high, normal, and low lung pressures to explore the influence of loud, normal, and soft utterances, respectively, on the airflow dynamics. The presented results demonstrate the variability of the airflow and droplet propagation as a function of the vocal tract geometrical characteristics and loudness.  more » « less
Award ID(s):
2029548
PAR ID:
10314437
Author(s) / Creator(s):
; ; ; ; ; ;
Date Published:
Journal Name:
The American Society of Mechanical Engineers Fluids Engineering Division Summer Meeting
Volume:
3
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. We investigate trajectories of microscale evaporating droplets in a stagnation point flow near a wall of a respiratory airway. The configuration is motivated by the problem of advection and deposition of microscale droplets of respiratory fluids in human airways during transmission of infectious diseases, such as tuberculosis and COVID-19. Laminar boundary layer equations are solved to describe the airflow while the equations of motion of the droplet include contributions from gravity, aerodynamic drag, and Saffman force. Evaporation is accounted for at both the droplet surfaceand the wall of the respiratory airway and is shown to delay droplet deposition as compared to the predictions of isothermal models. Evaporation at the airway wall has a stronger effect on droplet trajectories than evaporation at the droplet surface, leading to droplets being advected away by the flow and thus avoiding deposition in the stagnation point flow region. 
    more » « less
  2. Abstract How human respiratory physiology and the transport phenomena associated with inhaled airflow in the upper airway proceed to impact transmission of SARS-CoV-2, leading to the initial infection, stays an open question. An answer can help determine the susceptibility of an individual on exposure to a COVID-2019 carrier and can also provide a preliminary projection of the still-unknown infectious dose for the disease. Computational fluid mechanics enabled tracking of respiratory transport in medical imaging-based anatomic domains shows that the regional deposition of virus-laden inhaled droplets at the initial nasopharyngeal infection site peaks for the droplet size range of approximately 2.5–19 $$\upmu $$ μ . Through integrating the numerical findings on inhaled transmission with sputum assessment data from hospitalized COVID-19 patients and earlier measurements of ejecta size distribution generated during regular speech, this study further reveals that the number of virions that may go on to establish the SARS-CoV-2 infection in a subject could merely be in the order of hundreds. 
    more » « less
  3. Abstract Background Airborne viral pathogens like severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be encapsulated and transmitted through liquid droplets/aerosols formed during human respiratory events. Methods The number and extent of droplets/aerosols at distances between 1 and 6 ft (0.305–1.829 m) for a participant wearing no face covering, a cotton single-layer cloth face covering, and a 3-layer disposable face covering were measured for defined speech and cough events. The data include planar particle imagery to illuminate emissions by a light-sheet and local aerosol/droplet probes taken with phase Doppler interferometry and an aerodynamic particle sizer. Results Without face coverings, droplets/aerosols were detected up to a maximum of 1.25 m (4.1ft ± 0.22–0.28 ft) during speech and up to 1.37 m (4.5ft ± 0.19–0.33 ft) while coughing. The cloth face covering reduced maximum axial distances to 0.61 m (2.0 ft ± 0.11–0.15 ft) for speech and to 0.67 m (2.2 ft ± 0.02–0.20 ft) while coughing. Using the disposable face covering, safe distance was reduced further to 0.15 m (0.50 ft ± 0.01–0.03 ft) measured for both emission scenarios. In addition, the use of face coverings was highly effective in reducing the count of expelled aerosols. Conclusions The experimental study indicates that 0.914 m (3 ft) physical distancing with face coverings is equally as effective at reducing aerosol/droplet exposure as 1.829 m (6 ft) with no face covering. 
    more » « less
  4. Purpose:Articulatory behaviors during moments of stuttering have been understudied, largely due to the technical difficulty of collecting such data. Tracking moving articulators during stuttering requires advanced instrumentation, and eliciting stuttering in a lab setting poses challenges for experimental design. To address these difficulties, we present a novel methodology that combines real-time vocal tract magnetic resonance imaging (MRI) with a suite of connected speech tasks to elicit stuttering. Method:A high-performance 0.55 T MRI system, with a custom eight-channel upper airway coil and a spiral balanced steady-state free precession pulse sequence, was used to acquire real-time MRI speech production data from seven adults who stutter. During scans, participants performed three connected speech tasks that incorporate stuttering-inducing factors: (a) passage reading, (b) short interviews with the experimenter, and (c) picture description within a time limit. Speech tasks were interleaved with one another. Results:Each participant produced over 100 stuttered words, covering various disfluency types and linguistic features. Fluent and disfluent productions of the same words were elicited, enabling direct articulatory comparisons. Participants did not show a significant decrease in the percentage of syllables stuttered (%SS) inside the scanner compared to outside, suggesting that our protocol effectively mitigated fluency-enhancing factors during scanning. %SS in each speech task varied substantially across participants, justifying the inclusion of multiple task types. Interleaving different tasks helped maintain a stable %SS throughout. The collected real-time MRI vocal tract videos reveal meaningful articulatory behaviors during stuttering that are not detectable via acoustics alone. Conclusions:The suite of specially designed speech tasks was effective in eliciting stuttering during real-time MRI data collection. Combining these speech tasks with dynamic MRI technology offers a powerful approach to studying the articulatory mechanisms of stuttering. In addition to real-time MRI, these speech tasks have the potential to be combined with other experimental instrumentation to facilitate collecting data specifically during stuttered speech. 
    more » « less
  5. The nasopharynx, at the back of the nose, constitutes the dominant initial viral infection trigger zone along the upper respiratory tract. However, as per the standard recommended usage protocol (“Current Use”, or CU) for intranasal sprays, the nozzle should enter the nose almost vertically, resulting in sub-optimal nasopharyngeal drug deposition. Through the Large Eddy Simulation technique, this study has replicated airflow under standard breathing conditions with 15 and 30 L/min inhalation rates, passing through medical scan-based anatomically accurate human airway cavities. The small-scale airflow fluctuations were resolved through use of a sub-grid scale Kinetic Energy Transport Model. Intranasally sprayed droplet trajectories for different spray axis placement and orientation conditions were subsequently tracked via Lagrangian-based inert discrete phase simulations against the ambient inhaled airflow field. Finally, this study verified the computational projections for the upper airway drug deposition trends against representative physical experiments on sprayed delivery performed in a 3D-printed anatomic replica. The model-based exercise has revealed a new “Improved Use” (or, IU) spray usage protocol for viral infections. It entails pointing the spray bottle at a shallower angle (with an almost horizontal placement at the nostril), aiming slightly toward the cheeks. From the conically injected spray droplet simulations, we have summarily derived the following inferences: (a) droplets sized between 7–17  μ m are relatively more efficient at directly reaching the nasopharynx via inhaled transport; and (b) with realistic droplet size distributions, as found in current over-the-counter spray products, the targeted drug delivery through the IU protocol outperforms CU by a remarkable 2 orders-of-magnitude. 
    more » « less