Title: Rack-Level Thermosyphon Cooling and Vapor-Compression Driven Heat Recovery: Compressor Model
Abstract This paper introduces a novel thermal management solution coupling in-rack cooling and heat recovery system. System-level modeling capabilities are the key to design and analyze thermal performance for different applications. In this study, a semi-empirical model for a hermetically sealed scroll compressor is developed and applied to different scroll geometries. The model parameters are tuned and validated such that the model is applicable to a variety of working fluids. The identified parameters are split into two groups: one group is dependent on the compressor geometry and independent of working fluid, whereas the other group is fluid dependent. By modifying the fluid-dependent parameters using the specific heat ratios of two refrigerants, the model shows promise in predicting the refrigerant mass flow rate, discharge temperature and compressor shaft power of a third refrigerant. Here, the approach has been applied using data for two refrigerants (R22 and R134a) to achieve predictions for a third refrigerant’s (R407c) mass flow rate, discharge temperature, and compressor shaft power, with normalized root mean square errors of 0.01, 0.04 and 0.020, respectively. The normalization is performed based on the minimum and maximum values of the measured variable data. The technique thus presented in this study can be used to accurately predict the primary variables of interest for a scroll compressor running on a given refrigerant for which data may be limited, enabling component-level design or analysis for different operating conditions and system requirements.  more » « less
Award ID(s):
1738782
PAR ID:
10341809
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Proceedings of the 2021 ASME InterPACK
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    This paper introduces a novel thermal management solution coupling in-rack cooling and heat recovery system. System-level modeling capabilities are the key to design and analyze thermal performance for different applications. In this study, a semi-empirical model for a hermetically sealed scroll compressor is developed and applied to different scroll geometries. The model parameters are tuned and validated such that the model is applicable to a variety of working fluids. The identified parameters are split into two groups: one group is dependent on the compressor geometry and independent of working fluid, whereas the other group is fluid dependent. By modifying the fluid-dependent parameters using the specific heat ratios of two refrigerants, the model shows promise in predicting the refrigerant mass flow rate, discharge temperature and compressor shaft power of a third refrigerant. Here, the approach has been applied using data for two refrigerants (R22 and R134a) to achieve predictions for a third refrigerant’s (R407c) mass flow rate, discharge temperature, and compressor shaft power, with normalized root mean square errors of 0.01, 0.04 and 0.020, respectively. The normalization is performed based on the minimum and maximum values of the measured variable data. The technique thus presented in this study can be used to accurately predict the primary variables of interest for a scroll compressor running on a given refrigerant for which data may be limited, enabling component-level design or analysis for different operating conditions and system requirements. 
    more » « less
  2. Abstract A thermosyphon-based modular cooling approach offers an energy efficient cooling solution with an increased potential for waste heat recovery. Central to the cooling system is an air-refrigerant finned tube heat exchanger (HX), where air is cooled by evaporating refrigerant. This work builds on a previously published two-dimensional (2D) model for the finned-tube HX by updating and validating the model using in-house experimental data collected from the proposed system using R1233zd(E) as the working fluid. The results show that key system variables such as refrigerant outlet quality, air and refrigerant outlet temperatures, and exchanger duty agree within 20% of their experimental counterparts. The validated model is then used to predict the mean heat transfer coefficient on the refrigerant side for each tube in the direction of airflow, indicating a maximum heat transfer coefficient of nearly 1200 W/(m2 K) for a HX duty of 5.3 kW among the tested cases. The validated model therefore enables accurate predictions of HX performance and provides insights into improving the heat exchange efficiency and the corresponding system performance. 
    more » « less
  3. null (Ed.)
    Growing concerns about the global warming potential of hydrofluorocarbons (HFCs) has led to increasing interest in developing technologies to effectively recover and recycle these refrigerants. Ionic liquids (ILs) have shown great potential to selectively separate azeotropic HFC gas mixtures, such as R-410A composed of HFC-32 (CH2F2) and HFC-125 (CHF2CF3), based on solubility differences between the refrigerant gases in the respective IL. Isothermal vapor−liquid equilibrium (VLE) data for HFC-32 and HFC-125 were measured in ILs containing fluorinated and nonfluorinated anions using a gravimetric microbalance at pressures ranging from 0.05 to 1.0 MPa and a temperature of 298.15 K. The van der Waals equation of state (EoS) model was applied to correlate the experimental solubility data of each HFC refrigerant/IL mixture. The solubility differences between HFC-32 and HFC-125 vary significantly depending on the choice of IL. The diffusion coefficients for both HFC refrigerants in each IL were calculated by fitting Fick’s law to time-dependent absorption data. HFC-32 has a higher diffusivity in most ILs tested because of its smaller molecular radius relative to HFC-125. Based on the calculated Henry’s law constants and the mass uptake for each system, [C6C1im][Cl] was found to have the highest selectivity difference for separating R-410A at 298.15 K. 
    more » « less
  4. null (Ed.)
    An in-rack cooling system connected to an external vapor recompression loop can be an economical solution to harness waste heat recovery in data centers. Validated subsystem-level models of the thermosyphon cooling and recompression loops (evaporator, heat exchangers, compressor, etc.) are needed to predict overall system performance and to perform design optimization based on the operating conditions. This paper specifically focuses on the model of the evaporator, which is a finned-tube heat exchanger incorporated in a thermosyphon cooling loop. The fin-pack is divided into individual segments to analyze the refrigerant and air side heat transfer characteristics. Refrigerant flow in the tubes is modeled as 1-D flow scheme with transport equations solved on a staggered grid. The air side is modeled using differential equations to represent the air temperature and humidity ratio and to predict if moisture removal will occur, in which case the airside heat transfer coefficient is suitably reduced. The louver fins are modeled as individual hexagons and are treated in conjunction with the tube walls. A segment-by-segment approach is utilized for each tube and the heat exchanger geometry is subsequently evaluated from one end to the other, with air property changes considered for each subsequent row of tubes. Model predictions of stream outlet temperature and pressure, refrigerant outlet vapor quality and heat exchanger duty show good agreement when compared against a commercial software. 
    more » « less
  5. Abstract An in-rack cooling system connected to an external vapor recompression loop can be an economical solution to harness waste heat recovery in data centers. Validated subsystem-level models of the thermosyphon cooling and recompression loops (evaporator, heat exchangers, compressor, etc.) are needed to predict overall system performance and to perform design optimization based on the operating conditions. This paper specifically focuses on the model of the evaporator, which is a finned-tube heat exchanger incorporated in a thermosyphon cooling loop. The fin-pack is divided into individual segments to analyze the refrigerant and air side heat transfer characteristics. Refrigerant flow in the tubes is modeled as 1-D flow scheme with transport equations solved on a staggered grid. The air side is modeled using differential equations to represent the air temperature and humidity ratio and to predict if moisture removal will occur, in which case the airside heat transfer coefficient is suitably reduced. The louver fins are modeled as individual hexagons and are treated in conjunction with the tube walls. A segment-by-segment approach is utilized for each tube and the heat exchanger geometry is subsequently evaluated from one end to the other, with air property changes considered for each subsequent row of tubes. Model predictions of stream outlet temperature and pressure, refrigerant outlet vapor quality and heat exchanger duty show good agreement when compared against a commercial software. 
    more » « less