Upper-limb amputees commonly cite difficulty of control as one of the main reasons why they abandon their prostheses. Combining myoelectric control with autonomous sensor-based control could improve prosthesis control. However, the cognitive and physical impact of shared control and semi-autonomous systems on users has yet to be fully explored. In this study we introduce a novel shared-control algorithm that blends proportional position control predicted from electromyography (EMG) with proportional position control predicted from an autonomous machine using infrared sensors embedded in the prosthetic hand’s fingers to detect the distance to objects. The user’s EMG control is damped in proportion to the machine’s prediction of an object’s position in relation to a given finger. The shared-control algorithm was validated using three intact individuals completing a holding task where they attempted to hold an object for as long as possible without dropping it. Shared control resulted in fewer object drops, 32% less cognitive demand, and 49% less physical effort (measured by EMG) relative to the participant’s EMG control alone. These results indicate that shared control can reduce the physiological burdens on the user as well as increase prosthetic control.
more »
« less
Shared Control Decreases the Physical and Cognitive Demands of Maintaining a Secure Grip.
Upper-limb amputees commonly cite difficulty of control as one of the main reasons why they abandon their prostheses. Combining myoelectric control with autonomous sensor-based control could improve prosthesis control. However, the cognitive and physical impact of shared control and semi-autonomous systems on users has yet to be fully explored. In this study we introduce a novel shared-control algorithm that blends proportional position control predicted from electromyography (EMG) with proportional position control predicted from an autonomous machine using infrared sensors embedded in the prosthetic hand’s fingers to detect the distance to objects. The user’s EMG control is damped in proportion to the machine’s prediction of an object’s position in relation to a given finger. The shared-control algorithm was validated using three intact individuals completing a holding task where they attempted to hold an object for as long as possible without dropping it. Shared control resulted in fewer object drops, 32% less cognitive demand, and 49% less physical effort (measured by EMG) relative to the participant’s EMG control alone. These results indicate that shared control can reduce the physiological burdens on the user as well as increase prosthetic control.
more »
« less
- Award ID(s):
- 1901236
- PAR ID:
- 10353052
- Date Published:
- Journal Name:
- Proceedings of the Myoelectric Controls and Upper Limb Prosthetics Symposium.
- Page Range / eLocation ID:
- 82-85
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Objective: Physical and cognitive workloads and performance were studied for a corrective shared control (CSC) human–robot collaborative (HRC) sanding task. Background: Manual sanding is physically demanding. Collaborative robots (cobots) can potentially reduce physical stress, but fully autonomous implementation has been particularly challenging due to skill, task variability, and robot limitations. CSC is an HRC method where the robot operates semiautonomously while the human provides real-time corrections. Methods: Twenty laboratory participants removed paint using an orbital sander, both manually and with a CSC robot. A fully automated robot was also tested. Results: The CSC robot improved subjective discomfort compared to manual sanding in the upper arm by 29.5%, lower arm by 32%, hand by 36.5%, front of the shoulder by 24%, and back of the shoulder by 17.5%. Muscle fatigue measured using EMG, was observed in the medial deltoid and flexor carpi radialis for the manual condition. The composite cognitive workload on the NASA-TLX increased by 14.3% for manual sanding due to high physical demand and effort, while mental demand was 14% greater for the CSC robot. Digital imaging showed that the CSC robot outperformed the automated condition by 7.16% for uniformity, 4.96% for quantity, and 6.06% in total. Conclusions: In this example, we found that human skills and techniques were integral to sanding and can be successfully incorporated into HRC systems. Humans performed the task using the CSC robot with less fatigue and discomfort. Applications: The results can influence implementation of future HRC systems in manufacturing environments.more » « less
-
Tigrini, Andrea (Ed.)Hand gesture classification is crucial for the control of many modern technologies, ranging from virtual and augmented reality systems to assistive mechatronic devices. A prominent control technique employs surface electromyography (EMG) and pattern recognition algorithms to identify specific patterns in muscle electrical activity and translate these to device commands. While being well established in consumer, clinical, and research applications, this technique suffers from misclassification errors caused by limb movements and the weight of manipulated objects, both vital aspects of how we use our hands in daily life. An emerging alternative control technique is force myography (FMG) which uses pattern recognition algorithms to predict hand gestures from the axial forces present at the skin’s surface created by contractions of the underlying muscles. As EMG and FMG capture different physiological signals associated with muscle contraction, we hypothesized that each may offer unique additional information for gesture classification, potentially improving classification accuracy in the presence of limb position and object loading effects. Thus, we tested the effect of limb position and grasped load on 3 different sensing modalities: EMG, FMG, and the fused combination of the two. 27 able-bodied participants performed a grasp and release task with 4 hand gestures at 8 positions and under 5 object weight conditions. We then examined the effects of limb position and grasped load on gesture classification accuracy across each sensing modality. It was found that position and grasped load had statistically significant effects on the classification performance of the 3 sensing modalities and that the combination of EMG and FMG provided the highest classification accuracy of hand gesture, limb position, and grasped load combinations (97.34%) followed by FMG (92.27%) and then EMG (82.84%). This points to the fact that the addition of FMG to traditional EMG control systems offers unique additional data for more effective device control and can help accommodate different limb positions and grasped object loads.more » « less
-
Current lower-limb prostheses do not provide active assistance in postural control tasks to maintain the user’s balance, particularly in situations of perturbation. In this study, we aimed to address this missing function by enabling neural control of robotic lower-limb prostheses. Specifically, electromyographic (EMG) signals (amplified neural control signals) recorded from antagonistic residual ankle muscles were used to drive a robotic prosthetic ankle directly and continuously. Participants with transtibial amputation were recruited and trained in using the EMG-driven robotic ankle. We studied how using the EMG-controlled ankle affected the participants’ anticipatory and compensatory postural control strategies and stability under expected perturbations compared with using their daily passive devices. We investigated the similarity of neuromuscular coordination (by analyzing motor modules) of the participants, using either device in a postural sway task, to that of able-bodied controls. Results showed that, compared with their passive prosthesis, the EMG-controlled prosthesis enabled participants to use near-normative postural control strategies, as evidenced by improved between-limb symmetry in intact-prosthetic center-of-pressure and joint angle excursions. Participants substantially improved postural stability, as evidenced by a reduction in steps or falls using the EMG-controlled prosthetic ankle. Furthermore, after relearning to use residual ankle muscles to drive the robotic ankle in postural control, nearly all participants’ motor module structure shifted toward that observed in individuals without limb amputations. Here, we have demonstrated the potential benefit of direct EMG control of robotic lower limb prostheses to restore normative postural control strategies (both neural and biomechanical) toward enhancing standing postural stability in amputee users.more » « less
-
null (Ed.)Abstract Despite the promise of powered lower limb prostheses, existing controllers do not assist many daily activities that require continuous control of prosthetic joints according to human states and environments. The objective of this case study was to investigate the feasibility of direct, continuous electromyographic (dEMG) control of a powered ankle prosthesis, combined with physical therapist-guided training, for improved standing postural control in an individual with transtibial amputation. Specifically, EMG signals of the residual antagonistic muscles (i.e. lateral gastrocnemius and tibialis anterior) were used to proportionally drive pneumatical artificial muscles to move a prosthetic ankle. Clinical-based activities were used in the training and evaluation protocol of the control paradigm. We quantified the EMG signals in the bilateral shank muscles as well as measures of postural control and stability. Compared to the participant’s daily passive prosthesis, the dEMG-controlled ankle, combined with the training, yielded improved clinical balance scores and reduced compensation from intact joints. Cross-correlation coefficient of bilateral center of pressure excursions, a metric for quantifying standing postural control, increased to .83(±.07) when using dEMG ankle control ( passive device: .39(±.29)) . We observed synchronized activation of homologous muscles, rapid improvement in performance on the first day of the training for load transfer tasks, and further improvement in performance across training days (p = .006). This case study showed the feasibility of this dEMG control paradigm of a powered prosthetic ankle to assist postural control. This study lays the foundation for future study to extend these results through the inclusion of more participants and activities.more » « less
An official website of the United States government

