Pleated membrane filters are widely used to remove undesired impurities from a fluid in many applications. A filter membrane is sandwiched between porous support layers and then pleated and packed into an annular cylindrical cartridge with a central hollow duct for outflow. Although this arrangement offers a high surface filtration area to volume ratio, the filter performance is not as efficient as those of equivalent flat filters. In this paper, we use asymptotic methods to simplify the flow throughout the cartridge to systematically investigate how the number of pleats or pleat packing density affects the performance of the pleated membrane filters. The model is used to determine an optimal number of pleats in order to achieve a particular optimum filtration performance. Our findings show that only the “just right”—neither too few nor too many—number of pleats gives optimum performance in a pleated filter cartridge.
more »
« less
Flow and transport in a pleated filter
A pleated membrane filter consists of a porous membrane layer, which is surrounded by two supporting layers, and the whole structure is pleated and placed into a cylindrical cartridge. Pleated membrane filters are used in a variety of industrial applications, since they offer more surface area to volume ratio that is not found in equivalent flat filters. In this work, we introduce a novel three-dimensional model of a pleated membrane filter that consists of an empty region, a pleated region, and a hollow region. The advection diffusion equation is used to model contaminant concentration in the membrane pores along with Darcy's law to model the flow within the membrane and support layers, while the Stokes equation is used for the flow in the empty region and the hollow region. We further use the key assumptions of our model based on small aspect ratios of the filter cartridge and the pleated membrane to simplify the governing equations, which can be easily solved by numerical methods. By performing these steps, we seek to discover an optimal pleat packing density to find the optimum filter performance, while not exceeding a threshold for the particle concentration at the filter outlet.
more »
« less
- Award ID(s):
- 2108161
- PAR ID:
- 10354655
- Date Published:
- Journal Name:
- Physics of Fluids
- Volume:
- 34
- Issue:
- 9
- ISSN:
- 1070-6631
- Page Range / eLocation ID:
- 097102
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
null (Ed.)We study the influence of a membrane filter's internal pore structure on its flow and adsorptive fouling behaviour. Membrane performance is measured via (1) comparison between volumetric flow rate and throughput during filtration and (2) control of concentration of foulants at membrane pore outlets. Taking both measures into account, we address the merits and drawbacks of selected membrane pore structures. We first model layered planar membrane structures with intra-layer pore connections, and present comparisons between non-connected and connected structures. Our model predicts that membrane filters with connected pore structures lead to higher total volumetric throughput than those with non-connected structures, over the filter lifetime. We also provide a sufficient criterion for the concentration of particles escaping the filter to achieve a maximum in time (indicative of a membrane filter whose particle retention capability can deteriorate). Additionally, we find that the influence of intra-layer heterogeneity in pore-size distribution on filter performance depends on the connectivity properties of the pores.more » « less
-
We propose a new pore-scale/channel model, or hybrid model, for the fluid flow and particulate transport in gasoline particulate filters (GPFs). GPFs are emission control devices aimed at removing particulate out of the exhaust system of a gasoline direct injection engine. In this study, we consider a wall-flow uncoated GPF, which is made of a bundle of inlet and outlet channels separated by porous walls. The particulate-filled exhaust gas flows into the inlet channels, and passes through the porous walls before exiting out of the outlet channels. We model the flow inside the inlet and outlet channels using the incompressible Navier–Stokes equation coupled with the spatially averaged Navier–Stokes equation for the flow inside the porous walls. For the particulate transport, the coupled advection and spatially averaged advection–reaction equations are used, where the reaction term models the particulate accumulation. Using OpenFOAM, we numerically solve the flow and the transport equations and show that the concentration of deposited particles is nonuniformly distributed along the filter length, with an increase of concentration at the back end of the filter as Reynolds number increases. Images from X-ray computed tomography (XCT)-scanning experiments of the soot-loaded filter show that such a nonuniform distribution is consistent with the prediction obtained from the model. Finally, we show how the proposed model can be employed to optimize the filter design to improve filtration efficiency.more » « less
-
Protein fouling can significantly reduce the filtrate flux, capacity, and virus retention during processing of plasma- or mammalian cell-derived biopharmaceuticals through virus removal filters. We use focused ion beam (FIB) milling and scanning electron microscopy (SEM) to directly evaluate changes in 3D pore structure in a Viresolve® Pro membrane due to fouling by human serum immunoglobulin G. Protein fouling causes a significant reduction in the membrane porosity, which decreases by approximately 40% in the size-selective region near the exit of the highly asymmetric Viresolve® Pro membrane after the filter is fouled to 90% flux decline. There is a corresponding reduction in the number of small pores by more than a factor of two. Model simulations of flow and particle transport in the protein-fouled membrane are in good agreement with independent experimental measurements of the permeability and location of particle capture. Simulations show an upstream shift in the location of nanoparticle capture (away from the filter exit) by about 0.4 µm for the membrane fouled to 90% flux decline. This is due to pore constriction from protein deposition, highlighting how fouling redistributes flow paths within the membrane. These results demonstrate the capability of using FIB-SEM to directly evaluate the effects of protein fouling on the 3D pore structure in virus removal filters, providing important insights into how protein fouling alters the performance of these highly selective membranes.more » « less
-
Protection against airborne viruses has become very relevant since the outbreak of SARS-CoV-2. Nonwoven face masks along with heating, ventilation, and air conditioning (HVAC) filters have been used extensively to reduce infection rates; however, some of these filter materials provide inadequate protection due to insufficient initial filtration efficiency (FE) and FE decrease with time. Flat sheet porous membranes, which have been used extensively to filter waterborne microbes and particulate matter due to their high FE have the potential to filter air pollutants without compromising its FE over time. Therefore, in this study, single layer polysulfone (PSf) membranes were fabricated via non-solvent induced phase separation (NIPS) and were tested for airflow rate, pressure drop and FE. Polyethylene glycol (PEG) and glycerol were employed as pore-forming agents, and the effect of the primary polymer and pore-forming additive molecular weights (MW) on airflow rate and pressure drop were studied at different concentrations. The thermodynamic stability of dope solutions with different MWs of PSf and PEG in N-methylpyrrolidone (NMP) at different concentrations was determined using cloud-point measurements to construct a ternary phase diagram. Surface composition of the fabricated membranes was characterized using contact angle and X-ray photoelectron spectroscopy (XPS), while membrane morphology was characterized by SEM, and tensile strength experiments were performed to analyze the membrane mechanical strength (MS). It was observed that an increase in PSf and PEG molecular weight and concentration increased airflow and decreased pressure drop. PSf60:PEG20:NMP (15:15:70)% w/w showed the highest air flow rate and lowest pressure drop, but at the expense of the mechanical strength, which was improved significantly by attaching the membrane to a 3D-printed polypropylene support. Lastly, the FE values of the membranes were similar to those of double-layer N95 filters and significantly higher than those of single layer of N95, surgical mask and HVAC (MERV 11) filters.more » « less