skip to main content


Title: Soft Wireless Bioelectronics Designed for Real‐Time, Continuous Health Monitoring of Farmworkers
Abstract

Hotter summers caused by global warming and increased workload and duration are endangering the health of farmworkers, a high‐risk population for heat‐related illness (HRI), and deaths. Although prior studies using wearable sensors show the feasibility of employing field‐collected data for HRI monitoring, existing devices still have limitations, such as data loss from motion artifacts, device discomfort from rigid electronics, difficulties with administering ingestible sensors, and low temporal resolution. Here, this paper introduces a wireless, wearable bioelectronic system with functionalities for continuous monitoring of skin temperature, electrocardiograms (ECG), heart rates (HR), and activities, configured in a single integrated package. Advanced nanomanufacturing based on laser machining allows rapid device fabrication and direct incorporation of sensors with a highly breathable substrate, allowing for managing excessive sweating and multimodal stresses. To validate the device's performance in agricultural settings, the device is applied to multiple farmworkers at various operations, including fernery, nursery, and crop. The accurate data recording, including high‐fidelity ECG (signal‐to‐noise ratio: >20 dB), accurate HR (r= 0.89,r2= 0.65 in linear correlation), and reliable temperature/activity, confirms the device's capability for multiparameter health monitoring of farmworkers.

 
more » « less
NSF-PAR ID:
10368744
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Healthcare Materials
Volume:
11
Issue:
13
ISSN:
2192-2640
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Severe stress endangers outdoor workers who are in an exceedingly hot workplace. Although recent studies quantify stress levels on the human skin, they still rely on rigid, bulky sensor modules, causing data loss from motion artifacts and limited field‐deployability for continuous health monitoring. Moreover, no prior work shows a wearable device that can endure heat exposure while showing continuous monitoring of a subject's stress under realistic working environments. Herein, a soft, field‐deployable, wearable bioelectronic system is introduced for detecting outdoor workers' stress levels with negligible motion artifacts and controllable thermal management. A nanofabric radiative cooler (NFRC) and miniaturized sensors with a nanomembrane soft electronic platform are integrated to measure stable electrodermal activities and temperature in hot outdoor conditions. The NFRC exhibits outstanding cooling performance in sub‐ambient air with high solar reflectivity and high thermal emissivity. The integrated wearable device with all embedded electronic components and the NFRC shows a lower temperature (41.1%) in sub‐ambient air than the NFRC‐less device while capturing improved operation time (18.2%). In vivo human study of the bioelectronics with agricultural activities demonstrates the device's capability for portable, continuous, real‐time health monitoring of outdoor workers with field deployability.

     
    more » « less
  2. Abstract

    Recent developments of micro‐sensors and flexible electronics allow for the manufacturing of health monitoring devices, including electrocardiogram (ECG) detection systems for inpatient monitoring and ambulatory health diagnosis, by mounting the device on the chest. Although some commercial devices in reported articles show examples of a portable recording of ECG, they lose valuable data due to significant motion artifacts. Here, a new class of strain‐isolating materials, hybrid interfacial physics, and soft material packaging for a strain‐isolated, wearable soft bioelectronic system (SIS) is reported. The fundamental mechanism of sensor‐embedded strain isolation is defined through a combination of analytical and computational studies and validated by dynamic experiments. Comprehensive research of hard‐soft material integration and isolation mechanics provides critical design features to minimize motion artifacts that can occur during both mild and excessive daily activities. A wireless, fully integrated SIS that incorporates a breathable, perforated membrane can measure real‐time, continuous physiological data, including high‐quality ECG, heart rate, respiratory rate, and activities. In vivo demonstration with multiple subjects and simultaneous comparison with commercial devices captures the SIS's outstanding performance, offering real‐world, continuous monitoring of the critical physiological signals with no data loss over eight consecutive hours in daily life, even with exaggerated body movements.

     
    more » « less
  3. The objective of this study was to investigate the accuracy of a wearable photoplethysmography (PPG) sensor in monitoring heart rate (HR) of sheep housed in high-temperature environments. We hypothesized that the PPG sensor would be capable of differentiating low, normal, and high HR, but would struggle to produce exact HR estimates. The sensor was open source and comprised of a microprocessor (SparkFun®ThingPlus), a photoplethysmography sensor (SparkFun® MAX30101 & MAX32664), and a data storage module (SD Card 16GB), all sewn into a nylon collar with hook-and-loop closure. Sheep (n=4) were divided into 2 groups and exposed to different thermal environments in a cross-over design. The collar was placed around the neck of the sheep during the data collection phase and the manual HR were collected twice a day using a stethoscope. Precision and accuracy of numeric heart rate estimates were analyzed in R software using Pearson correlation and root mean squared prediction errors. Random forest regression was used to classify HR based on low, medium, and high to determine opportunities to leverage the PPG sensors for HR classification. Sensitivity, specificity, and accuracy were measured to evaluate the classification approach. Our results indicated that the PPG-based sensor measured sheep HR with poor accuracy and with higher average estimates in comparison with manually measured with a stethoscope. Categorical classification of HR was also poor, with accuracies ranging from 32% to 49%. Additional work is needed focusing on data analytics, and signal optimization to further rely on PPG sensors for accurately measuring HR in sheep.

     
    more » « less
  4. Abstract Background and Objectives Substance use disorders (SUDs) are chronic relapsing diseases characterized by significant morbidity and mortality. Phenomenologically, patients with SUDs present with a repeating cycle of intoxication, withdrawal, and craving, significantly impacting their diagnosis and treatment. There is a need for better identification and monitoring of these disease states. Remote monitoring chronic illness with wearable devices offers a passive, unobtrusive, constant physiological data assessment. We evaluate the current evidence base for remote monitoring of nonalcohol, nonnicotine SUDs. Methods We performed a systematic, comprehensive literature review and screened 1942 papers. Results We found 15 studies that focused mainly on the intoxication stage of SUD. These studies used wearable sensors measuring several physiological parameters (ECG, HR, O 2 , Accelerometer, EDA, temperature) and implemented study‐specific algorithms to evaluate the data. Discussion and Conclusions Studies were extracted, organized, and analyzed based on the three SUD disease states. The sample sizes were relatively small, focused primarily on the intoxication stage, had low monitoring compliance, and required significant computational power preventing “real‐time” results. Cardiovascular data was the most consistently valuable data in the predictive algorithms. This review demonstrates that there is currently insufficient evidence to support remote monitoring of SUDs through wearable devices. Scientific Significance This is the first systematic review to show the available data on wearable remote monitoring of SUD symptoms in each stage of the disease cycle. This clinically relevant approach demonstrates what we know and do not know about the remote monitoring of SUDs within disease states. 
    more » « less
  5. Abstract

    Graphene (Gr) has many unique properties including gapless band structure, ultrafast carrier dynamics, high carrier mobility, and flexibility, making it appealing for ultrafast, broadband, and flexible optoelectronics. To overcome its intrinsic limit of low absorption, hybrid structures are exploited to improve the device performance. Particularly, van der Waals heterostructures with different photosensitive materials and photonic structures are very effective for improving photodetection and modulation efficiency. With such hybrid structures, Gr hybrid photodetectors can operate from ultraviolet to terahertz, with significantly improvedR(up to 109A W−1) and bandwidth (up to 128 GHz). Furthermore, integration of Gr with silicon (Si) complementary metal‐oxide‐semiconductor (CMOS) circuits, the human body, and soft tissues is successfully demonstrated, opening promising opportunities for wearable sensors and biomedical electronics. Here, the recent progress in using Gr hybrid structures toward high‐performance photodetectors and integrated optoelectronic applications is reviewed.

     
    more » « less