Title: A Modified Directional Flame Thermometer: Development, Calibration, and Uncertainty Quantification
Abstract The directional flame thermometer (DFT) is a robust device used to measure heat fluxes in harsh environments such as fire scenarios but is large when compared to other standard heat flux measurement devices. To better understand the uncertainties associated with heat flux measurements in these environments, a Bayesian framework is utilized to propagate uncertainties of both known and unknown parameters describing the thermal model of a modified, smaller DFT. Construction of the modified DFT is described along with a derivation of the thermal model used to predict the incident heat flux to its sensing surface. Parameters of the model are calibrated to data collected using a Schmidt–Boelter (SB) gauge with an accuracy of ±3% at incident heat fluxes of 5 kW/m2, 10 kW/m2, and 15 kW/m2. Markov Chain Monte Carlo simulations were used to obtain posterior distributions for the free parameters of the thermal model as well as the modeling uncertainty. The parameter calibration process produced values for the free parameters that were similar to those presented in the literature with relative uncertainties at 5 kW/m2, 10 kW/m2, and 15 kW/m2 of 17%, 9%, and 7%, respectively. The derived model produced root-mean-squared errors between the prediction and SB gauge output of 0.37, 0.77, and 1.13 kW/m2 for the 5, 10, and 15 kW/m2 cases, respectively, compared to 0.53, 1.12, and 1.66 kW/m2 for the energy storage method (ESM) described in ASTM E3057.  more » « less
Award ID(s):
1707090
PAR ID:
10381194
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Journal of Verification, Validation and Uncertainty Quantification
Volume:
5
Issue:
1
ISSN:
2377-2158
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Jet impingement can be particularly effective for removing high heat fluxes from local hotspots. Two-phase jet impingement cooling combines the advantages of both the nucleate boiling heat transfer with the single-phase sensible cooling. This study investigates two-phase confined jet impingement cooling of local, laser-generated hotspots in a 100 nm thick Hafnium (Hf) thin film on glass. The jet/nozzle diameter is ∼1.2 mm and the normal distance between the nozzle outlet and the heated surface is ∼3.2 mm. The jet coolants studied are FC 72, Novec 7200, and Ethanol with jet nozzle outlet Reynolds numbers ranging from 250 to 5000. The hotspot area is ∼0.06 mm2 and the applied hotspot-to-jet heat fluxes range from 20 W/cm2 to 350 W/cm2. This heat flux range facilitates studies of both the single-phase and two-phase heat transport mechanisms for heat fluxes up to critical heat flux (CHF). The temporal evolution of the temperature distribution of the laser-heated surface is measured using infrared (IR) thermometry. This study focuses on the stagnation point heat transfer - i.e., the jet potential core is co-aligned with the hotspot center. For ethanol, the CHF is ∼315 W/cm2 at Re ∼ 1338 with a corresponding heat transfer coefficient of h ∼ 102 kW/m2·K. For FC 72, the CHF is ∼94 W/cm2 at Re ∼ 5000 with a corresponding h ∼ 56 kW/m2·K. And for Novec 7200, the CHF is ∼108 W/cm2 at Re ∼ 4600 with a corresponding h ∼ 50 kW/m2·K. 
    more » « less
  2. Liquid jet impingement is one of the most effective methods for dissipating local hotpot heat fluxes in microelectronics. Due to its normal incident flow-field, jet impingement cooling can achieve heat transfer coefficients (HTCs) approaching ≈1 MW/m 2 ·K due to its ability to thin the local thermal boundary layer in the stagnation region. This experimental study presents HTC data for water jet impingement cooling of a laser heated Hafnium (Hf) thin-film on glass. A laser diode induces local hotspots for either a steady- or pulsed-laser operation mode. The hotspots have areas ranging within 0.04 mm 2 to 0.2 mm 2 and heat fluxes up to ≈3.5 MW/m 2 . A submerged jet impingement configuration is pursued with an inlet jet diameter of ~1.2 mm, jet nozzle to hotspot/surface distance of ~3.2 mm, and the jet Reynolds Number of ~2004. The HTCs are measured using infrared (IR) thermometry using a 1.5-5 μm spectral resolution FLIR camera. Also investigated is the spatial dependence of the HTC relative to the offset between jet/wall stagnation point and the center of the local hotspot. For example, for impinging jets that are co-aligned with the hotspot center, HTCs of ~650 kW/m 2 ·K and ~470 kW/m 2 ·K are measured for steady and pulsed-modulated laser heating (respectively), whereas, for offsets beyond ~6 mm (x/D >5), the measured HTCs are <; 100 kW/m 2 ·K. 
    more » « less
  3. During the Arctic winter, the conductive heat flux through the sea ice and snow balances the radiative and turbulent heat fluxes at the surface. Snow on sea ice is a thermal insulator that reduces the magnitude of the conductive flux. The thermal conductivity of snow, that is, how readily energy is conducted, is known to vary significantly in time and space from observations, but most forecast and climate models use a constant value. This work begins with a demonstration of the importance of snow thermal conductivity in a regional coupled forecast model. Varying snow thermal conductivity impacts the magnitudes of all surface fluxes, not just conduction, and their responses to atmospheric forcing. Given the importance of snow thermal conductivity in models, we use observations from sea ice mass balance buoys installed during the Multidisciplinary drifting Observatory for the Study of Arctic Climate expedition to derive the profiles of thermal conductivity, density, and conductive flux. From 13 sites, median snow thermal conductivity ranges from 0.33 W m−1 K−1 to 0.47 W m−1 K−1 with a median from all data of 0.39 W m−1 K−1 from October to February. In terms of surface energy budget closure, estimated conductive fluxes are generally smaller than the net atmospheric flux by as much as 20 W m−2, but the average residual during winter is −6 W m−2, which is within the uncertainties. The spatial variability of conductive heat flux is highest during clear and cold time periods. Higher surface temperature, which often occurs during cloudy conditions, and thicker snowpacks reduce temporal and spatial variability. These relationships are compared between observations and the coupled forecast model, emphasizing both the importance and challenge of describing thermodynamic parameters of snow cover for modeling the Arctic as a coupled system. 
    more » « less
  4. This paper focuses on two-phase flow boiling of dielectric coolant HFE 7000 inside a copper multi-microchannel heat sink for high heat flux chip applications. The heat sink is composed of parallel microchannels, 200 μm wide, 2500 μm high, and 20 mm long, with 200-μm-thick fins separating the channels. The copper heat sink consists of almost 100 channels connected by a longitude groove with a nearly trapezoidal cross section. Coolant impinges down to the base at the groove and then goes along the microchannels. A copper block heater arrangement was used to mimic a computer chip with a footprint of 1”x1” (6.45 cm2). The base heat flux was varied from 7.75 W/cm2 to 96.1 W/cm2 and the mass flux from 547.6 to 958.4 kg/m2s, at a nominal saturation temperature of 54 °C. Heat transfer coefficients as high as 57.5 kW/m2K were reached, keeping the base temperature under 66 °C with a maximum of 21.9 kPa of pressure drop, for inlet subcooling of 5 degree and a coolant flow rate of 958.4 kg/m2. Effects of inner diameter of tubing on thermal performance and pressure drop are also discussed. It was observed that an increase of tubing inner diameter by 60 % can result in increase of heat transfer coefficient by 47.8 % and reduction in pressure drop by 63 %. 
    more » « less
  5. Abstract In fire hazard calculations, knowledge of the heat-release rate (HRR) of a burning item is imperative. Typically, room-scale calorimetry is conducted to determine the HRRs of common combustible items. However, this process can be prohibitively expensive. In this work, a method is proposed to invert for the HRR of a single item burning in a room using transient heat flux measurements at the walls and ceiling near the item. The primary device used to measure heat flux is the directional flame thermometer (DFT). The utility of the inverse method is explored on both synthetically generated and experimental data using two so-called forward models in the inversion algorithm: fire dynamics simulator (FDS) and the consolidated model of fire and smoke transport (CFAST). The fires in this work have peak HRRs ranging from 200 kW to 400 kW. It was found that FDS outperformed CFAST as a forward model at the expense of increased computational cost and that the error in the inverse reconstruction of a 400 kW steady fire was on par with room-scale oxygen consumption calorimetry. 
    more » « less